Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SPECTRASYN™ 40
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Base oil
Uses advised against
None unless specified elsewhere in this SDS.
Manufacturers & Suppliers
ExxonMobil Petroleum & Chemical BVBA on behalf of MOBIL CHEMICAL PRODUCTS INTERNATIONAL INC.
SYNTHETICS DEPARTMENT, HERMESLAAN 2, B-1831 MACHELEN, Belgium
+32-2-239 3111
Emergency Contacts
CHEMTREC
+(44)-8708200418
24 Hour
National Poison Control Centre
111
National Poison Control Centre
(+353)1 809 2166
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
No Hazardous Substance(s) required for disclosure.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from further exposure. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation.
Symptoms: respiratory irritation, dizziness, nausea, or unconsciousness
Wash contact areas with soap and water. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency.
Symptoms: initial symptoms from high pressure injection may be minimal or absent
Flush thoroughly with water.
Symptoms: irritation
First aid is normally not required.
Symptoms: discomfort
Immediate Medical Attention
If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If product is injected into or under the skin, or into any part of the body, the individual should be evaluated immediately by a physician as a surgical emergency.
Medical Treatment
Early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury for high pressure injection.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
Straight streams of water
Evacuate area. Use water spray to cool fire exposed surfaces and to protect personnel.
Firefighter Protection
Fire-fighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
In the event of a spill or accidental release, notify relevant authorities in accordance with all applicable regulations. Avoid contact with spilled material.
Dyke far ahead of liquid spill for later recovery and disposal.
Dyke far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas.
Recover by pumping or with suitable absorbent. Remove from the surface by skimming or with suitable absorbents.
Materials: suitable absorbent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent small spills and leakage to avoid slip hazard. Material is a static accumulator.
The type of container used to store the material may affect static accumulation and dissipation. Do not store in open or unlabelled containers.
Use proper bonding and/or earthing procedures. Material can accumulate static charges which may cause an electrical spark (ignition source). Consult local applicable standards for guidance (API 2003, NFPA 77, CENELEC CLC/TR 50404).
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation.
No protection is ordinarily required under normal conditions of use.
If contact is likely, safety glasses with side shields are recommended.
If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include: No protection is ordinarily required under normal conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapour warning properties are poor, or if air purifying filter capacity/rating may be exceeded.
No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.
Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
See sub-sections below.
Hazardous polymerization will not occur.
Excessive heat. High energy sources of ignition.
Strong oxidisers
Material does not decompose at ambient temperatures.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. TOXICITY
Material is not expected to be harmful to aquatic organisms.
12.2. PERSISTENCE AND DEGRADABILITY
The material is expected to biodegrade slowly.
12.3. BIOACCUMULATIVE POTENTIAL
12.4. MOBILITY IN SOIL
12.5. PERSISTENCE, BIOACCUMULATION AND TOXICITY FOR SUBSTANCE(S)
The product does not contain any substances that are classified as PBT or vPvB.
12.6. OTHER ADVERSE EFFECTS
No adverse effects are expected.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Listed or exempt from listing/notification on the following chemical inventories (May contain substance(s) subject to notification to the EPA Active TSCA inventory prior to import to USA): AICS, DSL, ENCS, IECSC, KECI, TSCA
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SPECTRASYN™ 40?
The signal word is no signal word.
What is the physical form of SPECTRASYN™ 40?
SPECTRASYN™ 40 is a liquid appearing as clear with colourless color. It has odourless odor.
What is SPECTRASYN™ 40 used for?
Base oil
What is the melting point of SPECTRASYN™ 40?
The melting point is No data available and the boiling point is No data available.