Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SIPTECH 12
Product Code
H012L

Regulatory Identifiers

CAS Number
64742-55-8 Check regulations →
EC Number
265-158-7 Check regulations →
REACH No.
01-2119487077-29-XXXX

Identified Uses

Manufacture of substance - Industrial, Use in metal working fluids/rolling oils - Industrial, Use in metal working fluids/rolling oils - Professional, Use in binder and release agents - Industrial, Use in binder and release agents - Professional, Use in agrochemicals - Professional, Use in agrochemicals - Consumer, Use in rubber production and processing - Industrial, Use in polymer processing - Industrial, Use as an intermediate - Industrial, Use in lubricants - Industrial, Use in lubricants (Low release) - Professional, Use in lubricants (high release) - Professional, Use in lubricants (Low release) - Consumer, Use in lubricants (high release) - Consumer, Use in laboratories - Industrial, Use in laboratories - Professional, Use in water treatment agents - Industrial, Use in water treatment agents - Professional, Use in explosives - Professional, Use in functional fluids - Industrial, Use in functional fluids - Professional, Other Consumer Uses - Consumer, Distribution of substance - Industrial, Formulation and (re)packing of substances and mixtures - Industrial, Use in cleaning agents - Industrial, Use in cleaning agents - Professional, Use in cleaning agents - Consumer, Uses in coatings - Industrial, Use in coatings - Professional, Use in coatings - Consumer

Uses advised against

None known.

Manufacturers & Suppliers

SIP Oils and Fluids Europe BV logo

SIP Oils and Fluids Europe BV

manufacturer

Lierseteenweg 400, 2800 Mechelen, Belgium

+44 207 7170100

https://sip.com/

Emergency Contacts

The National Poisons Information Centre (NPIC)

+353 (0) 1 809 2166

7 days a week, 8am- 10pm

The National Poisons Information Centre (NPIC)

+353 (0) 1 809 2566

24 h service

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/doctor.
P331 Do NOT induce vomiting.
P501 Dispose of contents/container in accordance with local regulation

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated light paraffinic EC: 265-158-7 64742-55-8 95 - 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Upon breathing difficulties or irritation of the respiratory tract: Bring the person into fresh air and stay with him/her.

Skin contact

Remove contaminated clothing and shoes immediately. Ensure to wash exposed skin thoroughly with water and soap. Skin cleanser can be used. DO NOT use solvents or thinners.

Symptoms: skin irritation

Eye contact

If in eyes: Flush eyes with water or saline water (20-30 °C) for at least 5 minutes. Remove contact lenses. Seek medical assistance and continue flushing during transport.

Ingestion

IF SWALLOWED: Immediately call a POISON CENTER/doctor. Do not induce vomiting! If vomiting occurs, keep head facing down so that vomit does not get into the lungs. Call a doctor or ambulance.

Symptoms: Symptoms of chemical pneumonia

Immediate Medical Attention

Immediately call a POISON CENTER/doctor. Seek medical assistance.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol-resistant foam, carbon dioxide, powder, water mist.

Unsuitable media

Waterjets should not be used, since they can spread the fire.

Specific hazards

Fire will result in dense smoke. Exposure to combustion products may harm your health.

Instructions

Closed containers, which are exposed to fire, should be cooled with water.

Firefighter Protection

Wear self-contained breathing apparatus and protective clothing to prevent contact.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid direct contact with spilled substances. Contaminated areas may be slippery.

Environmental

Avoid discharge to lakes, streams, sewers, etc.

Cleanup methods

cleaning should be performed with normal cleaning agents. Avoid use of solvents.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid direct contact with the product.

Storage

No specific requirements

Hygiene

Smoking, drinking and consumption of food is not allowed in the work area.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Apply standard precautions during use of the product. Avoid inhalation of vapours.

Hands

Material: Nitrile, Breakthrough time (min.): 480

Eyes

Type: Safety glasses, Standards: EN166

Respiratory

Respiratory protection is not needed in the event of adequate ventilation.

Skin/Body

Dedicated work clothing should be worn.

Environmental

Keep damming materials near the workplace. If possible, collect spillage during work.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Clear and bright
Colour Intensity
---
Form
---
Odor
Odourless
Odor Threshold
---
Ph
Not applicable
Melting Point
Not applicable
Boiling Point
No data available
Flash Point
188 °C
Freezing Point
Not applicable
Softening Point
Does not apply to liquids.
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0.83 g/cm³
Flammability
Not applicable
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
No data available
Solubility In Water
Insoluble
Solubility In Fat
Not applicable
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
11.6 mm²/s (40 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable under the conditions, noted in section 7 "Handling and storage".

Reactivity

No data available.

Hazardous reactions

None known.

Avoid

None known.

Incompatible

Strong oxidizing agents

Decomposition

The product is not degraded when used as specified in section 1.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Product/substance: Distillates (petroleum), hydrotreated light paraffinic Species: Fish, Oncorhynchus mykiss Duration: 96 hours Test: LC50 Result: 5000 mg/L

12.1. Toxicity

Product/substance: Distillates (petroleum), hydrotreated light paraffinic Species: Daphnia, Daphnia magna Duration: 48 hours Test: EC50 Result: 1000 mg/L

12.2. Persistence and degradability

12.2. Persistence and degradability

12.2. Persistence and degradability

Product/substance: Distillates (petroleum), hydrotreated light paraffinic Biodegradable: No Test method: Result:

12.3. Bioaccumulative potential

No data available.

12.4. Mobility in soil

No data available.

12.5. Results of PBT and vPvB assessment

This mixture/product does not contain any substances considered to meet the criteria classifying them as PBT and/or vPvB.

The mixture/product does not contain any substances considered to meet the criteria classifying them as PBT and/or vPvB.

12.6. Endocrine disrupting properties

Not applicable.

12.7. Other adverse effects

None known.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Product is not covered by regulations on dangerous waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Sources: Commission Regulation (EU) No 1357/2014 of 18 December 2014 on waste.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SIPTECH 12?

The signal word is danger.

What is the physical form of SIPTECH 12?

SIPTECH 12 is a liquid with clear and bright color. It has odourless odor.

What is SIPTECH 12 used for?

Manufacture of substance - Industrial, Use in metal working fluids/rolling oils - Industrial, Use in metal working fluids/rolling oils - Professional, Use in binder and release agents - Industrial, Use in binder and release agents - Professional, Use in agrochemicals - Professional, Use in agrochemicals - Consumer, Use in rubber production and processing - Industrial, Use in polymer processing - Industrial, Use as an intermediate - Industrial, Use in lubricants - Industrial, Use in lubricants (Low release) - Professional, Use in lubricants (high release) - Professional, Use in lubricants (Low release) - Consumer, Use in lubricants (high release) - Consumer, Use in laboratories - Industrial, Use in laboratories - Professional, Use in water treatment agents - Industrial, Use in water treatment agents - Professional, Use in explosives - Professional, Use in functional fluids - Industrial, Use in functional fluids - Professional, Other Consumer Uses - Consumer, Distribution of substance - Industrial, Formulation and (re)packing of substances and mixtures - Industrial, Use in cleaning agents - Industrial, Use in cleaning agents - Professional, Use in cleaning agents - Consumer, Uses in coatings - Industrial, Use in coatings - Professional, Use in coatings - Consumer

What are the hazard statements for SIPTECH 12?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways.

What is the melting point of SIPTECH 12?

The melting point is Not applicable and the boiling point is No data available.