Product Name
Therminol VP3-SA95 Heat Transfer Fluid
Product Code
34161-00, P3416101, P3416100, P3416103, P34161S2, E3416101

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Heat transfer fluids
Uses Advised Against
None known.

Overview

Therminol VP3-SA95 Heat Transfer Fluid commonly used heat transfer fluids.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Asp. Tox. Category 1 H304
Aquatic Acute Category 1 H400
Aquatic Chronic Category 1 H410

GHS Hazard Pictograms & Safety Symbols

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H304: May be fatal if swallowed and enters airways.
  • H410: Very toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P273: Avoid release to the environment.
  • P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
  • P331: Do NOT induce vomiting.
  • P391: Collect spillage.
  • P405: Store locked up.
  • P501: Dispose of contents/ container to an approved waste disposal plant.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Eastman Chemical Company company logo - Safety Data Sheet supplier organization

Eastman Chemical Company

manufacturer

๐Ÿ“

200 South Wilcox Drive 37660-5147 Kingsport

๐ŸŒ

US

๐Ÿ“ž

+14232292000

๐ŸŒ www.EASTMAN.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

NCEC

๐Ÿ“ž

+44 (0)1235 239 670

๐ŸŒ

GB

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Cyclohexylbenzene
EC: 212-572-0
827-52-1 90-100% โœ“ Non-hazardous
Bicyclohexyl
EC: 202-161-4
92-51-3 2.5-10% โš ๏ธ Hazardous

Additional Information

For explanation of abbreviations see section 16.

Composition Notes

The compositions of our documents reflect these requirements which include, but are not limited to, requirements under the Globally Harmonized System of Classification and Labeling (GHS). These compositions commonly involve the use of ranges versus specific analytical values. If you require a composition that is more specific, please refer to the Certificate of Analysis, sales specification, or contact your Customer Service Representative.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove person to fresh air and keep comfortable for breathing. Get medical attention if symptoms occur. If breathing is difficult, give oxygen.

๐Ÿ–๏ธ Skin Contact

Wash off with soap and plenty of water. Get medical attention if symptoms occur. Wash contaminated clothing before reuse.

Symptoms:

Causes mild skin irritation. Prolonged skin contact may defat the skin and produce dermatitis. The molten product can cause serious burns.

๐Ÿ‘๏ธ Eye Contact

In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if symptoms occur.

๐Ÿฝ๏ธ Ingestion/Swallowing

IF SWALLOWED: Immediately call a POISON CENTER/ doctor. Do NOT induce vomiting. Rinse mouth with water. Never give anything by mouth to an unconscious person.

Symptoms:

Aspiration hazard. May be fatal if swallowed and enters airways.

๐Ÿšจ Immediate Medical Attention Required

IF SWALLOWED: Immediately call a POISON CENTER/ doctor.

Medical Treatment

IF SWALLOWED: Immediately call a POISON CENTER/ doctor. Do NOT induce vomiting. Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
oily
Critical Property
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
mild
๐Ÿ“Š Odor Threshold
not determined
๐Ÿงช Ph
not determined
๐ŸงŠ Melting Point
3 - 5 C
Critical Property
๐Ÿ’จ Boiling Point
243 C
Critical Property
๐Ÿ”ฅ Flash Point
104 C
Critical Property
๐Ÿ“Š Freezing Point
3 - 5 C
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
not determined
๐Ÿ’จ Vapor Pressure
0,16 hPa (40 C)
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
0,934 (25 C)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
923 kg/m3 (40 C)
Critical Property
๐Ÿ”ฅ Flammability
Not applicable
๐Ÿ“Š Upper Explosive Limit
not determined
๐Ÿ“Š Lower Explosive Limit
not determined
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
not determined
๐Ÿ“Š Decomposition Temperature
not determined
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
log Pow: > 4
๐Ÿ“Š Solubility In Water
< 0,023 g/l (20 C)
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
2,0 mPa.s (38 C)
๐Ÿ“Š Kinematic Viscosity
2,04 mm2/s (40 C)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

๐Ÿงค Hand Protection

Wear suitable gloves.

๐Ÿ‘๏ธ Eye Protection

Wear safety glasses with side shields (or goggles).

๐Ÿ˜ท Respiratory Protection

Use a properly fitted, particulate filter respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. If engineering controls do not maintain airborne concentrations below recommended exposure limits (where applicable) or to an acceptable level (in countries where exposure limits have not been established), an approved respirator must be worn.

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 3082

โš ๏ธ Transport Hazard Class

9

๐Ÿ“‹ Packing Group

III

๐Ÿšข IMDG Maritime Transport Precautions

Shipping in package sizes of less than 5 L (liquids) or 5 KG (solids) may lead to a non-regulated classification.

โœˆ๏ธ IATA Air Transport Precautions

Shipping in package sizes of less than 5 L (liquids) or 5 KG (solids) may lead to a non-regulated classification.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Therminol VP3-SA95 Heat Transfer Fluid?

The signal word for this substance is "danger".

What is the physical form of Therminol VP3-SA95 Heat Transfer Fluid?

Therminol VP3-SA95 Heat Transfer Fluid is a oily with colourless color. It has mild odor.

What is Therminol VP3-SA95 Heat Transfer Fluid used for?

Heat transfer fluids

What are the hazard statements for Therminol VP3-SA95 Heat Transfer Fluid?

This substance has 2 hazard statements: H304: May be fatal if swallowed and enters airways. H410: Very toxic to aquatic life with long lasting effects.

What is the melting point of Therminol VP3-SA95 Heat Transfer Fluid?

The melting point is 3 - 5 C and the boiling point is 243 C.