Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Delo XLC PG Antifreeze/Coolant - Concentrate
- Product Code
- 804150
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Antifreeze/Coolant
Manufacturers & Suppliers
Chevron Products UK Limited
manufacturer
1 Westferry Circus, Canary Wharf, London E14 4HA, United Kingdom
Emergency Contacts
Transportation Emergency Response
0044/(0)18 65 407333
CHEMTREC
+1 703 527 3887
Chevron Emergency Information Center
+1 510 231 0623
24 hours
Emergency Contact
0044/(0)18 65 407333
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Propane-1,2-diol EC: 200-338-0 | 57-55-6 | 80 - 98% | No |
| Sodium 2-ethylhexanoate EC: 243-283-8 | 19766-89-3 | 0.1 - 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If exposed to excessive levels of material in the air, move the exposed person to fresh air.
Symptoms: Not expected to be harmful if inhaled.
Remove clothing and shoes if contaminated. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.
Symptoms: Contact with the skin is not expected to be harmful.
Remove contact lenses, if worn, and flush eyes with water.
Symptoms: Not expected to cause prolonged or significant eye irritation.
Do not induce vomiting.
Symptoms: Not expected to be harmful if swallowed.
Immediate Medical Attention
As a precaution, get medical advice for ingestion. Get medical attention if coughing or respiratory discomfort occurs after inhalation.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.
For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Firefighter Protection
Do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Refer to Sections 5 and 8 for more information.
Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.
Use appropriate techniques such as applying non-combustible absorbent materials or pumping.
Materials: non-combustible absorbent materials
Related Products
Similar products with comparable safety profiles
Delo XLC Antifreeze/Coolant - Premixed 50/50
UFI: 64F9-20Y7-N00J-58PR
Heavy Duty PF Antifreeze/Coolant - Concentrate
---
Liebherr Antifreeze OS Concentrate
UFI: H710-80G4-X00Q-3VM9
Havoline Conventional Antifreeze/Coolant - Concentrate
---
Liebherr Antifreeze Concentrate - First Fill
---
Scania Coolant Concentrate
---
Cat® ELC™ (Extended Life Coolant) Concentrate with Embitterment
---
Bobcat Propylene Glycol Antifreeze & Coolant Premix
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Wash thoroughly after handling.
Not Applicable
Wash thoroughly after handling.
Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere (including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use in a well-ventilated area.
Suggested materials for protective gloves include: Neoprene, Nitrile Rubber, Polyvinyl Chloride (PVC or Vinyl).
No special eye protection is normally required. Where splashing is possible, wear safety glasses with side shields as a good safety practice.
No respiratory protection is normally required.
No special protective clothing is normally required. Where splashing is possible, select protective clothing depending on operations conducted, physical requirements and other substances in the workplace.
See relevant Community environmental protection legislation or the Annex, as applicable.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Hazardous polymerization will not occur.
Not applicable
Not applicable
None known (None expected)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
The material is not expected to be harmful to aquatic organisms based on the properties of its individual components.
12.2 Persistence and degradability
This material is expected to be readily biodegradable based on the properties of its individual components, as the product itself has not been tested.
12.3 Bioaccumulative potential
No data available for bioconcentration factor or octanol/water partition coefficient.
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The product does not contain substances classified as PBT or vPvB.
12.6 Other adverse effects
No other adverse effects identified.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Use material for its intended purpose or recycle if possible.
This material, if it must be discarded, may meet the criteria of a hazardous waste as defined by international, country, or local laws and regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No components of this material were found on the regulatory lists 01-13.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Delo XLC PG Antifreeze/Coolant - Concentrate?
The signal word is no signal word.
What is the physical form of Delo XLC PG Antifreeze/Coolant - Concentrate?
Delo XLC PG Antifreeze/Coolant - Concentrate is a liquid appearing as colorless with colorless color. It has faint or mild odor.
What is the solubility of Delo XLC PG Antifreeze/Coolant - Concentrate?
Soluble in water.
What is Delo XLC PG Antifreeze/Coolant - Concentrate used for?
Antifreeze/Coolant
What is the melting point of Delo XLC PG Antifreeze/Coolant - Concentrate?
The melting point is Not Applicable and the boiling point is 170°C (338°F) (Estimated).