Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CarbonSmart HP Ethanol
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Use according to manufacturer's directions. The use of a quantity of material in an unventilated or confined space may result in increased exposure and an irritating atmosphere developing. Before starting consider control of exposure by mechanical ventilation.
Uses advised against
No specific uses advised against are identified.
Manufacturers & Suppliers
LanzaTech
manufacturer
8045 Lamon Avenue, Suite 400 Skokie IL 60077 United States
+1 847 324 2400
http://www.LanzaTech.com
Emergency Contacts
LanzaTech
+1 877 715 9305
24 Hours
CHEMWATCH EMERGENCY RESPONSE (24/7)
+32 2 700 63 06
CHEMWATCH EMERGENCY RESPONSE (24/7)
+61 3 9573 3188
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
If fumes or combustion products are inhaled remove from contaminated area. Lay patient down. Keep warm and rested. Prostheses such as false teeth, which may block airway, should be removed, where possible, prior to initiating first aid procedures. Apply artificial respiration if not breathing, preferably with a demand valve resuscitator, bag-valve mask device, or pocket mask as trained. Perform CPR if necessary. Transport to hospital, or doctor.
Immediately remove all contaminated clothing, including footwear. Flush skin and hair with running water (and soap if available). Seek medical attention in event of irritation.
Wash out immediately with fresh running water. Ensure complete irrigation of the eye by keeping eyelids apart and away from eye and moving the eyelids by occasionally lifting the upper and lower lids. Seek medical attention without delay; if pain persists or recurs seek medical attention. Removal of contact lenses after an eye injury should only be undertaken by skilled personnel.
If swallowed do NOT induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain open airway and prevent aspiration. Observe the patient carefully. Never give liquid to a person showing signs of being sleepy or with reduced awareness; i.e. becoming unconscious. Give water to rinse out mouth, then provide liquid slowly and as much as casualty can comfortably drink. Seek medical advice.
Immediate Medical Attention
Seek medical attention without delay; if pain persists or recurs seek medical attention (Eye). Seek medical attention in event of irritation (Skin). Transport to hospital, or doctor (Inhalation). Seek medical advice (Ingestion).
Medical Treatment
Acute ingestion in non-tolerant patients usually responds to supportive care with special attention to prevention of aspiration, replacement of fluid and correction of nutritional deficiencies (magnesium, thiamine pyridoxine, Vitamins C and K). Give 50% dextrose (50-100 ml) IV to obtunded patients following blood draw for glucose determination. Comatose patients should be treated with initial attention to airway, breathing, circulation and drugs of immediate importance (glucose, thiamine).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol stable foam, Dry chemical powder, BCF (where regulations permit), Carbon dioxide.
Do not use a water jet to fight fire.
Avoid contamination with oxidising agents i.e. nitrates, oxidising acids, chlorine bleaches, pool chlorine etc. as ignition may result
Alert Fire Brigade and tell them location and nature of hazard. May be violently or explosively reactive. Prevent, by any means available, spillage from entering drains or water course.
Firefighter Protection
Wear breathing apparatus plus protective gloves in the event of a fire.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
See section 8
Remove all ignition sources. Clean up all spills immediately. Avoid breathing vapours and contact with skin and eyes. Control personal contact with the substance, by using protective equipment.
Clear area of personnel and move upwind. Alert Fire Brigade and tell them location and nature of hazard. May be violently or explosively reactive. Wear breathing apparatus plus protective gloves.
See section 12
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Containers, even those that have been emptied, may contain explosive vapours. Do NOT cut, drill, grind, weld or perform similar operations on or near containers. Contains low boiling substance: Storage in sealed containers may result in pressure buildup causing violent rupture of containers not rated appropriately. Check for bulging containers. Vent periodically. Always release caps or seals slowly to ensure slow dissipation of vapours. DO NOT allow clothing wet with material to stay in contact with skin. Avoid all personal contact, including inhalation. Wear protective clothing when risk of exposure occurs. Use in a well-ventilated area. Prevent concentration in hollows and sumps.
Store in original containers in approved flame-proof area. Keep containers securely sealed. DO NOT store in pits, depression, basement or areas where vapours may be trapped.
No smoking, naked lights, heat or ignition sources. See section 5.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Well-designed engineering controls can be highly effective in protecting workers and will typically be independent of worker interactions to provide this high level of protection. The basic types of engineering controls are: Process controls which involve changing the way a job activity or process is done to reduce the risk. Enclosure and/or isolation of emission source which keeps a selected hazard "physically" away from the worker and ventilation that strategically "adds" and "removes" air in the work environment.
Wear chemical protective gloves, e.g. PVC. The selection of suitable gloves does not only depend on the material, but also on further marks of quality which vary from manufacturer to manufacturer. Where the chemical is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time for substances has to be obtained from the manufacturer of the protective gloves and has to be observed when making a final choice. Recommended materials: BUTYL (A), NEOPRENE (A), NATURAL RUBBER (C), NATURAL+NEOPRENE (C), NITRILE (C), NITRILE+PVC (C), PE/EVAL/PE (C), PVA (C), PVC (C), VITON (C).
Safety glasses with side shields. Chemical goggles. [AS/NZS 1337.1, EN166 or national equivalent] Contact lenses may pose a special hazard; soft contact lenses may absorb and concentrate irritants. A written policy document, describing the wearing of lenses or restrictions on use, should be created for each workplace or task.
Type A Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent). Where the concentration of gas/particulates in the breathing zone, approaches or exceeds the "Exposure Standard" (or ES), respiratory protection is required. Cartridge respirators should never be used for emergency ingress or in areas of unknown vapour concentrations or oxygen content. The wearer must be warned to leave the contaminated area immediately on detecting any odours through the respirator. Cartridge performance is affected by humidity. Cartridges should be changed after 2 hr of continuous use unless it is determined that the humidity is less than 75%, in which case, cartridges can be used for 4 hr. Used cartridges should be discarded daily, regardless of the length of time used.
Wear safety footwear or safety gumboots, e.g. Rubber. Overalls. PVC Apron. PVC protective suit may be required if exposure severe. Some plastic personal protective equipment (PPE) (e.g. gloves, aprons, overshoes) are not recommended as they may produce static electricity. For large scale or continuous use wear tight-weave non-static clothing (no metallic fasteners, cuffs or pockets). Non sparking safety or conductive footwear should be considered. Conductive footwear describes a boot or shoe with a sole made from a conductive compound chemically bound to the bottom components, for permanent control to electrically ground the foot and shall dissipate static electricity from the body to reduce the possibility of ignition of volatile compounds.
See section 12
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Unstable in the presence of incompatible materials. Product is considered stable.
See section 7.2
Hazardous polymerisation will not occur.
See section 7.2
See section 7.2
See section 5.3
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.3. Bioaccumulative potential
12.4 Mobility in soil
12.2. Persistence and degradability
12.4. Mobility in soil
12.1. Toxicity
12.2. Persistence and degradability
12.3 Bioaccumulative potential
12.2. Persistence and degradability
12.5. Results of PBT and vPvB assessment
PBT and vPvB criteria not fulfilled.
12.6. Endocrine disrupting properties
12.7. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Recycle wherever possible. Consult manufacturer for recycling options or consult local or regional waste management authority for disposal if no suitable treatment or disposal facility can be identified. Dispose of by: burial in a land-fill specifically licensed to accept chemical and / or pharmaceutical wastes or Incineration in a licensed apparatus (after admixture with suitable combustible material).
This material may be recycled if unused, or if it has not been contaminated so as to make it unsuitable for its intended use.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1170
- Shipping Name
- ETHANOL SOLUTION (ETHYL ALCOHOL SOLUTION); ETHANOL (ETHYL ALCOHOL)
- Transport Class
- 3
- Packing Group
- II
Special provisions: 144; Limited Quantities: 1 L
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Not Applicable
This safety data sheet is in compliance with the following EU legislation and its adaptations - as far as applicable - : Directives 98/24/EC, - 92/85/EEC, - 94/33/EC, - 2008/98/EC, - 2010/75/EU; Commission Regulation (EU) 2020/878; Regulation (EC) No 1272/2008 as updated through ATPs.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CarbonSmart HP Ethanol?
The signal word is danger.
What is the physical form of CarbonSmart HP Ethanol?
CarbonSmart HP Ethanol is a liquid appearing as clear highly flammable liquid with an alcohol odour; miscible with water. . It has not available odor.
What is CarbonSmart HP Ethanol used for?
Use according to manufacturer's directions. The use of a quantity of material in an unventilated or confined space may result in increased exposure and an irritating atmosphere developing. Before starting consider control of exposure by mechanical ventilation.
What are the hazard statements for CarbonSmart HP Ethanol?
This substance has 2 hazard statements:
- H225: Highly flammable liquid and vapour.
- H319: Causes serious eye irritation.
What is the melting point of CarbonSmart HP Ethanol?
The melting point is -130 °C and the boiling point is Not Available.