Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Sustainable Aviation Fuel (SAF); HEFA-SPK
- Chemical Name
- renewable hydrocarbons (kerosene type fraction)
Regulatory Identifiers
- CAS Number
- 2252265-89-5 Check regulations →
Identified Uses
Industrial and commercial applications, Propellant
Manufacturers & Suppliers
EcoCeres Ltd
manufacturer
2302-2303, 23/F, Tower 2, The Quayside, 77 Hoi Bun Road Kwun Tong Hong Kong
Emergency Contacts
Emergency Contact
As above or nearest toxicological information centre.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| renewable hydrocarbons (kerosene type fraction) | 2252265-89-5 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air. Mouth to mouth resuscitation should be avoided. Use alternative methods, preferably with oxygen or compressed air driven apparatus. If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions.
After contact with skin, take off immediately all contaminated clothing, and wash immediately with plenty of water and soap.
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Rinse mouth. Do not induce vomiting. Call a physician in any case.
Immediate Medical Attention
Call a physician in any case. If breathing is irregular or stopped, immediately seek medical assistance.
Medical Treatment
None.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
water spray, alcohol resistant foam, fire extinguishing powder, carbon dioxide (CO2)
water jet
Combustible. In case of insufficient ventilation and/or in use, may form flammable/explosive vapour-air mixture. Solvent vapours are heavier than air and may spread along floors. Places which are not ventilated, e.g. unventilated below ground level areas such as trenches, conduits and shafts, are particularly prone to the presence of flammable substances or mixtures.
Keep containers cool with water spray. Co-ordinate firefighting measures to the fire surroundings. Fight fire with normal precautions from a reasonable distance.
Firefighter Protection
Wear self-contained breathing apparatus
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Remove persons to safety. Ventilate affected area.
Remove from the water surface (e.g. skimming, sucking). Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it.
Collect spillage. Place in appropriate containers for disposal.
Materials: sand, diatomaceous earth, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
Neste MY Sustainable Aviation Fuel (HEFA-SPK)
---
Aviation Jet Fuel JET A-1 / Neste Renewable Jet Fuel
---
Aviation Jet Fuel JET A-1 / Neste Renewable Jet Fuel
---
Neste Renewable Jet Fuel
---
SAFETY CLEAN FS
---
HYDRANSAFE HFA S7
---
SAFELUB BIO EP
---
Aviation Jet Fuel JET A-1 (JETA1)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Do not breathe vapour/spray.
Keep container tightly closed and in a well-ventilated place. Keep cool. Protect from sunlight.
Do not eat, drink and smoke in work areas. Wash hands after use. Preventive skin protection (barrier creams/ointments) is recommended. Remove contaminated clothing and protective equipment before entering eating areas.
Keep away from sources of ignition - No smoking. Take precautionary measures against static discharge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use local and general ventilation.
Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. Check leak-tightness/impermeability prior to use. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves.
Wear eye/face protection.
In case of inadequate ventilation wear respiratory protection.
Protective clothing against liquid chemicals.
Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The material is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
This material is not reactive under normal ambient conditions. If heated: Risk of ignition.
No known hazardous reactions.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Take precautionary measures against static discharge. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools.
oxidisers
Reasonably anticipated hazardous decomposition products produced as a result of use, storage, spill and heating are not known. Hazardous combustion products: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
Based on available data, the classification criteria are not met.
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
The substance is readily biodegradable.
12.2 Persistence and degradability
Persistence
No data available.
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance is not a PBT or a vPvB.
12.6 Other adverse effects
Data are not available.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of contents/container in accordance with local/regional/national/international regulations.
This material and its container must be disposed of as hazardous waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1863
- Shipping Name
- FUEL, AVIATION, TURBINE ENGINE
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
There is no additional information.
There is no additional information.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Sustainable Aviation Fuel (SAF); HEFA-SPK?
The signal word is danger.
What is the physical form of Sustainable Aviation Fuel (SAF); HEFA-SPK?
Sustainable Aviation Fuel (SAF); HEFA-SPK is a liquid with colourless color. It has characteristic odor.
What is Sustainable Aviation Fuel (SAF); HEFA-SPK used for?
Industrial and commercial applications, Propellant
What are the hazard statements for Sustainable Aviation Fuel (SAF); HEFA-SPK?
This substance has 3 hazard statements:
- H226: Flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H313 + H333: May be harmful in contact with skin or if inhaled.
What is the melting point of Sustainable Aviation Fuel (SAF); HEFA-SPK?
The melting point is <-20 °C (ECHA, EU method A.1) and the boiling point is 130 – 275 °C at 100.2 kPa (ECHA, OECD Guideline 103).