Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- OLOA 54720
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- RSNC-C0ME-M00K-PD4K
Identified Uses
Automotive lubricant additive
Uses advised against
Consult supplier when used other than those specified.
Manufacturers & Suppliers
Chevron Oronite S.A.S.
manufacturer
Le Corosa CS10022, 1, rue Eugène et Armand Peugeot, 92508 Rueil-Malmaison Cedex, France
+33 1 46 39 36 00
Emergency Contacts
Chevron Emergency Information Centre
+(1) 510-231-0623
Emergency Contact
1 800 009 010
Emergency Contact
(+86) 4001-204937
Emergency Contact
+(33)-975181407
Emergency Contact
+(1)-703-741-5970
CHEMTREC
(800) 424-9300
Emergency Contact
(703) 527-3887
Chevron Oronite Brasil Ltda
55 11 4478-1200
24 hours
ORFILA (INRS)
+33 (0)1 45 42 59 59
Emergency Contact
+(33)-975181407
Emergency Contact
+(1)-703-741-5970
Emergency Contact
(800) 231-0623
24 hours
Emergency Contact
(510) 231-0623
24 hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Highly refined mineral oil (C15 - C50) | --- | 40 - 45% | No |
| Reaction products of diphenylamine with nonene, branched EC: 701-385-4 | --- | 5 - 10% | Yes |
| Phosphorodithioic acid, mixed O,O-bis(sec-Bu and 1,3-dimethylbutyl) esters, zinc salts EC: 272-238-5 | 68784-31-6 | 1 - 5% | Yes |
| Benzoic acid, 2-hydroxy-, mono-C14-18-alkyl derivs., calcium salts EC: 601-337-1 | 114959-46-5 | 1 - 5% | Yes |
| Reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate EC: 406-040-9 | 125643-61-0 | 1 - 5% | Yes |
| Benzenesulfonic acid, methyl-, mono-C20-24-branched alkyl derivs., calcium salts EC: 682-816-2 | 722503-68-6 | 1 - 5% | Yes |
| (Tetrapropenyl)succinic acid EC: 248-698-8 | 27859-58-1 | 0.1 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If exposed to excessive levels of material in the air, move the exposed person to fresh air. If exposure to hydrogen sulfide (H2S) gas is possible during an emergency, move the exposed person to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Symptoms: coughing or respiratory discomfort
Wash skin with water immediately and remove contaminated clothing and shoes. To remove the material from skin, apply a waterless hand cleaner, mineral oil, or petroleum jelly. Then wash with soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.
Symptoms: Contact with the skin may cause an allergic skin reaction. Symptoms may include pain, itching, discoloration, swelling, and blistering.
Remove contact lenses, if worn, and flush eyes with water.
Symptoms: Not expected to cause prolonged or significant eye irritation.
Do not induce vomiting.
Symptoms: Not expected to be harmful if swallowed.
Immediate Medical Attention
Get medical attention if any symptoms develop. Get medical advice. Get medical attention if coughing or respiratory discomfort occurs. Get immediate medical attention.
Medical Treatment
Administration of 100% oxygen and supportive care is the preferred treatment for poisoning by hydrogen sulfide gas.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.
For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Firefighter Protection
Do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Observe all relevant local and international regulations. Keep out unnecessary and unprotected personnel. Persons entering the contaminated area to correct the problem or to determine whether it is safe to resume normal activities must comply with all instructions in the Exposure Controls/Personal Protection section.
Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.
Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent materials or pumping.
Materials: non-combustible absorbent materials
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Do not breathe gas. Wash thoroughly after handling.
Storage temperatures for up to 2 weeks should not exceed 66°C (150°F). The recommended long-term (2 weeks or more) storage temperature is ambient to 45°C (113°F) maximum.
Wash thoroughly after handling.
Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere and use appropriate mitigating procedures. Do not expose containers to heat, flame, sparks, static electricity, or other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use general ventilation, local exhaust ventilation, or a combination of both.
Using chemical PPE depends upon operations conducted and may include chemical gloves. Refer to PPE manufacturers to obtain breakthrough time information to determine how long PPE can be used before it needs to be replaced. Unless specific glove manufacturer data indicates otherwise, the below table is based upon available industry data to assist in the glove selection process and is intended to be used as reference only. Chemical Glove Material: Butyl (0.7mm, 120 minutes), Neoprene (0.75mm, 30 minutes), Nitrile (0.85mm, 15 minutes), Polyvinyl Chloride (PVC) (1.5mm, 30 minutes), Viton Butyl (0.3mm, 120 minutes).
Wear protective equipment to prevent eye contact. Selection of protective equipment may include safety glasses, chemical goggles, face shields, or a combination depending on the work operations conducted.
A site-specific risk assessment should be conducted by an Occupational Hygienist or a Safety Professional to determine the type and use of respiratory protective equipment. When a site-specific risk assessment determines that respiratory protection is required, use an approved respirator such as: Air purifying respirator - If airborne concentration limits exceed the applicable occupational exposure limit, but are below the maximum use concentration. Vapors only: organic vapor cartridge (filter type A3 per EN 529:2005). Vapors and particulates (including generated mists): both an organic vapor cartridge & particulate filter (AP3 filter per EN 529:2005). Refer to respirator manufacturers to obtain service life of cartridge / filter. Positive pressure air-supplying respirator - If airborne concentration limits exceed the maximum use concentration offered from an air purifying respirator. If hydrogen sulfide (H2S) airborne concentrations exceed its applicable occupational exposure limits due to this material being heated. For more information on H2S, see Chevron SDS 301. Refer to EN 529:2005, USA OSHA 1910.134, and/or other applicable local/regional/national/international standards for regulatory requirements.
Wear chemical personal protective equipment (PPE) to prevent skin contact. Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves, boots, chemical apron, chemical suit, and complete facial protection.
See relevant Community environmental protection legislation or the Annex, as applicable.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Hazardous polymerization will not occur.
Do not exceed handling and storage temperatures listed in SDS Section 7 (Handling and Storage).
Not applicable
Alkyl Mercaptans (See Section 7), Hydrogen Sulfide (See Section 7)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The material does not meet the criteria for PBT or vPvB.
12.6 Endocrine Disrupting Properties
The mixture does not contain any substances that are assessed as having endocrine disrupting properties.
12.7 Other adverse effects
No other adverse effects identified.
12.1 Toxicity
Based on available data, the classification criteria are not met
Acute Toxicity
12.1 Toxicity
12.1 Toxicity
Based on available data, the classification criteria are not met
Acute Toxicity
12.1 Toxicity
Based on available data, the classification criteria are not met
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.1 Toxicity
Based on available data, the classification criteria for long-term toxicity are not met.
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
Based on available data, the classification criteria for long-term toxicity are not met.
12.1 Toxicity
12.1 Toxicity
Based on available data, the classification criteria are not met
12.1 Toxicity
Based on available data, the classification criteria for long-term toxicity are not met.
12.2 Persistence and degradability
12.2 Persistence and degradability
Based on available data, the classification criteria are not met
12.2 Persistence and degradability
12.2 Persistence and degradability
Based on available data, the classification criteria are not met
12.2 Persistence and degradability
12.2 Persistence and degradability
Based on available data, the classification criteria are not met
12.2 Persistence and degradability
Based on available data, the classification criteria are not met for (Tetrapropenyl)succinic acid.
Bioaccumulative potential
Bioaccumulative Potential
Based on available data, the classification criteria are not met
Bioaccumulative Potential
No test data available
Bioaccumulative Potential
Based on available data, the classification criteria are not met
12.3 Bioaccumulative potential
No test data available
Bioaccumulative potential
Bioaccumulative potential
Based on available data, the classification criteria are not met
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Use material for its intended purpose or recycle if possible.
This material, if it must be discarded, may meet the criteria of a hazardous waste as defined by international, country, or local laws and regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No components of this material were found on the regulatory lists searched (EU Directives 92/85/EEC, 2012/18/EU, 98/24/EC, 2004/37/EC, EC No. 689/2008, EC No. 850/2004, REACH Annex XVII, REACH Annex XIV, France INRS).
Please contact Oronite at SDS_REACH@chevron.com for more information concerning EU-REACH.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for OLOA 54720?
The signal word is warning.
What is the physical form of OLOA 54720?
OLOA 54720 is a liquid appearing as brown with brown color. It has petroleum odor odor.
What is the solubility of OLOA 54720?
Insoluble in water.
What is OLOA 54720 used for?
Automotive lubricant additive
What are the hazard statements for OLOA 54720?
This substance has 3 hazard statements:
- H317: May cause an allergic skin reaction
- H361f: Suspected of damaging fertility
- H412: Harmful to aquatic life with long lasting effects
What is the melting point of OLOA 54720?
The melting point is No data available and the boiling point is No data available.