Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- OLOA 61007
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- Q4F6-90WW-V00Q-3JV3
Identified Uses
Automotive lubricant additive
Manufacturers & Suppliers
Chevron Oronite S.A.S.
manufacturer
Le Corosa CS10022, 1, rue Eugène et Armand Peugeot, 92508 Rueil-Malmaison Cedex, France
+33 1 46 39 36 00
Emergency Contacts
Chevron Emergency Information Centre
+(1) 510-231-0623
Emergency Contact
1 800 009 010
Emergency Contact
(+86) 4001-204937
Emergency Contact
+(33)-975181407
Emergency Contact
+(1)-703-741-5970
CHEMTREC
(800) 424-9300
CHEMTREC
(703) 527-3887
Chevron Oronite Brasil Ltda
55 11 4478-1200
24 hours
ORFILA (INRS)
+33 (0)1 45 42 59 59
Emergency Contact
+(33)-975181407
Emergency Contact
+(1)-703-741-5970
Emergency Contact
(800) 231-0623
Emergency Contact
(510) 231-0623
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
In accordance with the Regulation (EC)No 1272/2008, Nota L, reference IP 346/92: "DMSO Extraction Method", we have determined that the base oils used in this preparation are not carcinogenic. The classification as a reproductive toxicant, category 1B only applies to this UVCB substance or mixture when Phenol, dodecyl-, branched (EC 310-154-3) is present at ≥ 0.3 % w/w. This is the only constituent of this UVCB substance with reprotoxic properties. The other constituents (phenate and base oil) are not classified as a reproductive hazard based on test data.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Highly refined mineral oil (C15 - C50) | --- | 35 - 40% | No |
| Reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate EC: 406-040-9 | 125643-61-0 | 5 - 10% | No |
| Phosphorodithioic acid, mixed O,O-bis(sec-Bu and 1,3-dimethylbutyl) esters, zinc salts EC: 272-238-5 | 68784-31-6 | 5 - 10% | No |
| Phenol,paraalkylation prod. with C10-15 branched olefins (C12 rich) derived from propene oligomerization,carbonates,Ca salts,overbased,sulfurized including dist. (petroleum),hydrotreated, solvent-refined/dewaxed,cat.dewaxed,light/heavy paraffinic C15-C50† EC: 701-251-5 | 68784-26-9 | 1 - 5% | No |
| Alkyl (C18-C28) toluenesulfonic acid, calcium salts, borated EC: 953-650-0 | --- | 1 - 5% | No |
| Benzenesulfonic acid, methyl-, mono-C20-24-branched alkyl derivs., calcium salts EC: 682-816-2 | 722503-68-6 | 1 - 5% | No |
| Phenol, dodecyl-, branched*** EC: 310-154-3 | 121158-58-5 | 0.3 - 1.5% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs. If exposure to hydrogen sulfide (H2S) gas is possible during an emergency, wear an approved, positive pressure air-supplying respirator. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get immediate medical attention.
Symptoms: Coughing, difficulty breathing, respiratory irritation, irritation of the eyes, nose, and throat. Moderate levels can cause headache, dizziness, nausea, and vomiting. Higher levels can cause shock, convulsions, coma, and death.
Wash skin with water immediately and remove contaminated clothing and shoes. Get medical attention if any symptoms develop. To remove the material from skin, apply a waterless hand cleaner, mineral oil, or petroleum jelly. Then wash with soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.
Symptoms: Allergic skin reaction. Symptoms may include pain, itching, discoloration, swelling, and blistering.
Remove contact lenses, if worn, and flush eyes with water.
Symptoms: Not expected to cause prolonged or significant eye irritation.
Do not induce vomiting. As a precaution, get medical advice.
Symptoms: Not expected to be harmful if swallowed.
Immediate Medical Attention
Get medical attention if any symptoms develop (skin), if coughing or respiratory discomfort occurs (inhalation), or immediate medical attention for H2S exposure.
Medical Treatment
Administration of 100% oxygen and supportive care is the preferred treatment for poisoning by hydrogen sulfide gas.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
Combustion Products: Highly dependent on combustion conditions. A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.
This material will burn although it is not easily ignited. See Section 7 for proper handling and storage.
Firefighter Protection
For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.
Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent materials or pumping.
Materials: non-combustible absorbent materials
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Do not breathe gas. Wash thoroughly after handling. Toxic quantities of hydrogen sulfide (H2S) may be present in storage tanks and bulk transport vessels. Persons opening or entering these compartments should first determine if H2S is present.
The recommended long-term (2 weeks or more) storage temperature is ambient to 45°C (113°F) maximum. Storage temperatures for up to 2 weeks should not exceed 66°C (150°F).
Wash thoroughly after handling.
Electrostatic charge may accumulate and create a hazardous condition. Bonding and grounding may be necessary. Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere (including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use general ventilation, local exhaust ventilation, or a combination of both.
Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves. Refer to PPE manufacturers to obtain breakthrough time information to determine how long PPE can be used before it needs to be replaced. Chemical Glove Material: Butyl (0.35 mm, 5 min), Neoprene (1.4 mm, 30 min), Nitrile (0.8 mm, 30 min), Nitrile (0.23 mm, 7 min), Polyvinyl Chloride (PVC) (1.1 mm, 15 min), Viton Butyl (0.3 mm, 120 min).
Wear protective equipment to prevent eye contact. Selection of protective equipment may include safety glasses, chemical goggles, face shields, or a combination depending on the work operations conducted.
No respiratory protection is normally required. If material is heated and emits hydrogen sulfide, determine if airborne concentrations are below the occupational exposure limit for hydrogen sulfide. If not, wear an approved positive pressure air-supplying respirator. For more information on hydrogen sulfide, see Chevron SDS No. 301. If user operations generate an oil mist, determine if airborne concentrations are below the occupational exposure limit for mineral oil mist. If not, wear an approved respirator that provides adequate protection from the measured concentrations of this material. For air-purifying respirators use a particulate cartridge.
Wear chemical personal protective equipment (PPE) to prevent skin contact. Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves, boots, chemical apron, chemical suit, and complete facial protection.
See relevant Community environmental protection legislation or the Annex, as applicable.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Hazardous polymerization will not occur.
Do not exceed handling and storage temperatures listed in SDS Section 7 (Handling and Storage).
Not applicable
Alkyl Mercaptans (See Section 7), Hydrogen Sulfide (See Section 7)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Use material for its intended purpose or recycle if possible.
This material, if it must be discarded, may meet the criteria of a hazardous waste as defined by international, country, or local laws and regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not applicable
- Shipping Name
- Not applicable
- Transport Class
- Not applicable
- Packing Group
- Not applicable
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Please contact Oronite at SDS_REACH@chevron.com for more information concerning EU-REACH.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for OLOA 61007?
The signal word is danger.
What is the physical form of OLOA 61007?
OLOA 61007 is a liquid appearing as color: brown with brown color. It has petroleum odor odor.
What is the solubility of OLOA 61007?
Insoluble in water.
What is OLOA 61007 used for?
Automotive lubricant additive
What are the hazard statements for OLOA 61007?
This substance has 3 hazard statements:
- H317: May cause an allergic skin reaction
- H360: May damage fertility or the unborn child
- H412: Harmful to aquatic life with long lasting effects
What is the melting point of OLOA 61007?
The melting point is No data available and the boiling point is No data available.