Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ClinMass® Internal Standard IS for Trace Elements in Plasma / Serum
- Product Code
- MS50012
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Product for in-vitro diagnostic use
Manufacturers & Suppliers
RECIPE Chemicals + Instruments GmbH
manufacturer
Dessauerstr. 3, 80992 Munich
+49 (0)89 547081-0
http://www.recipe.de
Emergency Contacts
24-h-Emergency Phone Number
+49 / (0)700 24112112 (RCR)
Mon - Sun 12:00 AM - 11:59 PM
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Reagent with various analytes.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| propan-2-ol EC: 200-661-7 | 67-63-0 | 5 - 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. Provide fresh air.
Wash with plenty of soap and water.
Remove contact lenses, if present and easy to do. Continue rinsing. Irrigate copiously with clean, fresh water for at least 10 minutes, holding the eyelids apart.
Rinse mouth with water (only if the person is conscious). Do NOT induce vomiting.
Immediate Medical Attention
In all cases of doubt, or when symptoms persist, seek medical advice. If breathing is irregular or stopped, immediately seek medical assistance.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, BC-powder, Carbon dioxide (CO2)
Water jet
In case of insufficient ventilation and/or in use, may form flammable/explosive vapour-air mixture. Solvent vapours are heavier than air and may spread along floors. Places which are not ventilated, e.g. unventilated below ground level areas such as trenches, conduits and shafts, are particularly prone to the presence of flammable substances or mixtures.
Co-ordinate firefighting measures to the fire surroundings. Fight fire with normal precautions from a reasonable distance.
Firefighter Protection
In case of fire and/or explosion do not breathe fumes.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
For non-emergency personnel: Remove persons to safety. For emergency responders: Wear breathing apparatus if exposed to vapours/dust/spray/gases.
Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it.
Wipe up with absorbent material (e.g. cloth, fleece). Collect spillage: sawdust, kieselgur (diatomite), sand, universal binder
Materials: cloth, fleece, sawdust, kieselgur (diatomite), sand, universal binder
Related Products
Similar products with comparable safety profiles
ClinMass® Diluting Solution D for Trace Elements in Plasma / Serum
---
ClinMass® FAST Carrier Solution for Trace Elements in Plasma / Serum
---
ClinMass® Autosampler Washing Solution for Trace Elements in Plasma / Serum
---
ClinCal® Serum Calibrator Set, lyophil., for Trace Elements, Level 1 - 4
---
Calcium standard solution 1000 µg/ml (Plasma HIQU)
---
Magnesium standard solution 1000 µg/ml (Plasma HIQU)
---
SPLASH® Lipidomix® Mass Spec Standard
---
Iridium Internal Standard: 10 µg/mL Ir in 2% HCl [100ml bottle]
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use local and general ventilation. Avoidance of ignition sources. Keep away from sources of ignition - No smoking. Take precautionary measures against static discharge. Use only in well-ventilated areas. Due to danger of explosion, prevent leakage of vapours into cellars, flues and ditches. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools.
Keep container tightly closed and in a well-ventilated place. Keep cool. Protect from sunlight. Protect from moisture. Protect against external exposure, such as frost.
Wash hands after use. Do not eat, drink and smoke in work areas. Remove contaminated clothing and protective equipment before entering eating areas. Never keep food or drink in the vicinity of chemicals. Never place chemicals in containers that are normally used for food or drink. Keep away from food, drink and animal feedingstuffs.
Avoidance of ignition sources. Keep away from sources of ignition - No smoking. Take precautionary measures against static discharge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
General ventilation.
Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. Check leak-tightness/impermeability prior to use. In the case of wanting to use the gloves again, clean them before taking off and air them well. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves.
Wear eye/face protection.
In case of inadequate ventilation wear respiratory protection.
Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
See below 'Conditions to avoid'.
The mixture contains reactive substance(s). Risk of ignition. If heated: Risk of ignition
No known hazardous reactions.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools. Take precautionary measures against static discharge.
Oxidisers
Reasonably anticipated hazardous decomposition products produced as a result of use, storage, spill and heating are not known. Hazardous combustion products: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
The substance is not classified as hazardous to the aquatic environment.
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance does not contain PBT or vPvB components at concentrations of 0.1% or higher.
12.6 Endocrine disrupting properties
Does not contain an endocrine disruptor (ED) at a concentration of ≥ 0,1%.
12.7 Other adverse effects
Data are not available.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Solvent reclamation/regeneration.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1219
- Shipping Name
- ISOPROPANOL
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Safety, health and environmental regulations/legislation specific for the substance or mixture
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ClinMass® Internal Standard IS for Trace Elements in Plasma / Serum?
The signal word is danger.
What is the physical form of ClinMass® Internal Standard IS for Trace Elements in Plasma / Serum?
ClinMass® Internal Standard IS for Trace Elements in Plasma / Serum is a liquid with colourless color. It has information on this property is not available odor.
What is the solubility of ClinMass® Internal Standard IS for Trace Elements in Plasma / Serum?
not determined
What is ClinMass® Internal Standard IS for Trace Elements in Plasma / Serum used for?
Product for in-vitro diagnostic use
What are the hazard statements for ClinMass® Internal Standard IS for Trace Elements in Plasma / Serum?
This substance has 1 hazard statement:
- H225: Highly flammable liquid and vapour.
What is the melting point of ClinMass® Internal Standard IS for Trace Elements in Plasma / Serum?
The melting point is not determined and the boiling point is 82.4 °C at 1,013 hPa (calculated value, referring to a component of the mixture).