01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Texaform PR 7
Product Code
832696

Regulatory Identifiers

CAS Number
N/A
UFI Code
MQ87-S04M-7002-V983

Identified Uses

Industrial Oil

Manufacturers & Suppliers

C

Chevron Belgium BV

manufacturer

Zuiderpoort Office Park, Gaston Crommenlaan 4, 9050 Gent, Belgium

0032/(0)9 293 71 11

Emergency Contacts

CHEMTREC

+1 703 527 3887

Centre Antipoisons

+32022649636

Chevron Emergency Information Center

+1 510 231 0623

International calls accepted 24 hours

Poison Control Center

0032/(0)70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways

Precautionary Statements

P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician
P331 Do NOT induce vomiting
P405 Store locked up
P501 Dispose of contents/container in accordance with applicable local/regional/national/international regulations

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Highly refined mineral oil (C15 - C50) --- 70 - 99% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No specific first aid measures are required. If exposed to excessive levels of material in the air, move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.

Symptoms: Not expected to be harmful if inhaled. Contains a petroleum-based mineral oil. May cause respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include coughing and difficulty breathing.

Skin contact

No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.

Symptoms: Contact with the skin is not expected to be harmful.

Eye contact

No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water.

Symptoms: Not expected to cause prolonged or significant eye irritation.

Ingestion

If swallowed, get immediate medical attention. Do not induce vomiting. Never give anything by mouth to an unconscious person.

Symptoms: Because of its low viscosity, this material can directly enter the lungs, if swallowed, or if subsequently vomited. Once in the lungs it is very difficult to remove and can cause severe injury or death.

Immediate Medical Attention

If swallowed, get immediate medical attention. Get medical attention if coughing or respiratory discomfort occurs.

Medical Treatment

Ingestion of this product or subsequent vomiting may result in aspiration of light hydrocarbon liquid, which may cause pneumonitis.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Specific hazards

Highly dependent on combustion conditions. A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.

Instructions

For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.

Firefighter Protection

Do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Eliminate all sources of ignition in vicinity of spilled material. Refer to Sections 5 and 8 for more information.

Environmental

Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.

Cleanup methods

Use appropriate techniques such as applying non-combustible absorbent materials or pumping.

Materials: non-combustible absorbent materials

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Wash thoroughly after handling.

Storage

Not Applicable

Hygiene

Wash thoroughly after handling.

Fire prevention

Electrostatic charge may accumulate and create a hazardous condition when handling this material. To minimize this hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient. Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere (including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use in a well-ventilated area.

Hands

Chemical gloves. Butyl (0.7 mm, 120 minutes), Nitrile (0.8 mm, 240 minutes), Viton Butyl (0.3 mm, 240 minutes). Refer to PPE manufacturers to obtain breakthrough time information to determine how long PPE can be used before it needs to be replaced.

Eyes

Wear protective equipment to prevent eye contact. Selection of protective equipment may include safety glasses, chemical goggles, face shields, or a combination depending on the work operations conducted.

Respiratory

No respiratory protection is normally required. If user operations generate an oil mist, determine if airborne concentrations are below the occupational exposure limit for mineral oil mist. If not, wear an approved respirator that provides adequate protection from the measured concentrations of this material. For air-purifying respirators use a particulate cartridge.

Skin/Body

Wear chemical personal protective equipment (PPE) to prevent skin contact. Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves, boots, chemical apron, chemical suit, and complete facial protection.

Environmental

See relevant Community environmental protection legislation or the Annex, as applicable.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Brown to yellow
Colour Intensity
---
Form
---
Odor
Petroleum odor
Odor Threshold
No data available
Ph
Not Applicable
Melting Point
---
Boiling Point
---
Flash Point
(Cleveland Open Cup) 115 °C (239 °F) (Minimum)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0.8450 kg/l @ 15°C (59°F) (Typical)
Flammability
No Data Available
Upper Explosive Limit
Not Applicable
Lower Explosive Limit
Not Applicable
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
Soluble in hydrocarbons; insoluble in water
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
6.80 mm²/s @ 40°C (104°F) (Minimum)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Reactivity

May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Not applicable

Incompatible

Not applicable

Decomposition

None known (None expected)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

This material is not expected to be harmful to aquatic organisms. The product has not been tested. The statement has been derived from the properties of the individual components.

This material is not expected to be harmful to aquatic organisms.

12.2 Persistence and degradability

This material is not expected to be readily biodegradable. The product has not been tested. The statement has been derived from the properties of the individual components.

This material is not expected to be readily biodegradable.

12.3 Bioaccumulative potential

Bioconcentration Factor: No Data Available Octanol/Water Partition Coefficient: No data available

12.4 Mobility in soil

No data available.

12.5 Results of PBT and vPvB assessment

This product is not, or does not contain, a substance that is a potential PBT or a vPvB.

The product is not, or does not contain, a substance that is a potential PBT or a vPvB.

12.6 Endocrine Disrupting Properties

This mixture does not contain any substances that are assessed as having endocrine disrupting properties.

The mixture does not contain any substances that are assessed as having endocrine disrupting properties.

12.7 Other adverse effects

No other adverse effects identified.

No other adverse effects identified.

Acute Toxicity

Highly refined mineral oil (C15 - C50) Based on available data, the classification criteria are not met

12.1 Toxicity

Long-term Toxicity: Based on available data, the classification criteria are not met

Based on available data, the classification criteria are not met

12.2 Persistence and degradability

Biodegradation: Based on available data, the classification criteria are not met

Bioaccumulative Potential

Highly refined mineral oil (C15 - C50) | Based on available data, the classification criteria are not met

Based on available data, the classification criteria are not met

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Use material for its intended purpose or recycle if possible.

Disposal

This material, if it must be discarded, may meet the criteria of a hazardous waste as defined by international, country, or local laws and regulations.

Waste Codes

13 02 05 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No components of this material were found on the regulatory lists above.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Texaform PR 7?

The signal word is danger.

What is the physical form of Texaform PR 7?

Texaform PR 7 is a liquid with brown to yellow color. It has petroleum odor odor.

What is the solubility of Texaform PR 7?

Soluble in hydrocarbons; insoluble in water

What is Texaform PR 7 used for?

Industrial Oil

What are the hazard statements for Texaform PR 7?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways