Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- GRIFFON DEVMOR AER 300ML*12 L1
- Product Code
- 1235612
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Metal-working product
Manufacturers & Suppliers
Bison International
manufacturer
Dr.A.F.Philipsstraat 9 NL-4462 EW Goes PO Box 160 NL-4460 AD Goes
+31 88 3235700
Emergency Contacts
Emergency Contact
+31 88 3235700
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Metal working product
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| acetone EC: 200-662-2 | 67-64-1 | 10 - 25% | Yes |
| propan-2-ol EC: 200-661-7 | 67-63-0 | 10 - 25% | Yes |
| propane EC: 200-827-9 | 74-98-6 | 10 - 25% | Yes |
| isobutane EC: 200-857-2 | 75-28-5 | 2.5 - 10% | Yes |
| butane EC: 203-448-7 | 106-97-8 | 25 - 50% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Generally the product does not irritate the skin.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Do not induce vomiting; call for medical help immediately.
Immediate Medical Attention
Consult doctor in case of complaints (inhalation), if symptoms persist (eye contact), or immediately (ingestion).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Dispose contaminated material as waste according to item 13.
Related Products
Similar products with comparable safety profiles
GRF HT-120 BO 500ML*12 L222
---
GRF UNI-100 XT BO 1L*8 ENDE
---
GRF UNI-100 XT BO 1L*8 ENDE
---
GRF UNI-100 BO 250ML*24 ENDE
---
GRF PE CLNR HEAVY DUTY BO 1L*12 L105
---
DURAPIPE AIRLINE EXTRA BOT 500ML*12 L202
---
GRF GASLEAKDETECTOR AE 400ML*12 L313
---
GRF LOCK SPRAY AE 150ML*12 L223
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke. Do not pierce or burn, even after use.
Observe official regulations on storing packagings with pressurised containers. Keep receptacle tightly sealed.
Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact of a maximum of 15 minutes gloves made of the following materials are suitable: PVC or PE gloves
Tightly sealed goggles
Not required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No decomposition if used according to specifications.
No further relevant information available.
Danger of forming toxic pyrolysis products.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
No further relevant information available regarding aquatic toxicity.
12.2 Persistence and degradability
12.3 Bioaccumulative potential
No further relevant information available.
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance is not considered to be PBT or vPvB.
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
Must not be disposed together with household garbage.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2
- Packing Group
- Void
Warning: Gases.
Warning: Gases. Stowage Code: SW1 Protected from sources of heat. SW22 For AEROSOLS with a maximum capacity of 1 litre: Category A. For AEROSOLS with a capacity above 1 litre: Category B. For WASTE AEROSOLS: Category C, Clear of living quarters. Segregation Code: SG69 For AEROSOLS with a maximum capacity of 1 litre: Segregation as for class 9. Stow 'separated from' class 1 except for division 1.4. For AEROSOLS with a capacity above 1 litre: Segregation as for the appropriate subdivision of class 2. For WASTE AEROSOLS: Segregation as for the appropriate subdivision of class 2.
Warning: Gases.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for GRIFFON DEVMOR AER 300ML*12 L1?
The signal word is danger.
What is the physical form of GRIFFON DEVMOR AER 300ML*12 L1?
GRIFFON DEVMOR AER 300ML*12 L1 is a aerosol with according to product specification color. It has characteristic odor.
What is GRIFFON DEVMOR AER 300ML*12 L1 used for?
Metal-working product
What are the hazard statements for GRIFFON DEVMOR AER 300ML*12 L1?
This substance has 3 hazard statements:
- H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of GRIFFON DEVMOR AER 300ML*12 L1?
The melting point is Undetermined. and the boiling point is -44 °C.