NextSDS Logo
Safety Data Sheet EN

GRIFFON DEVMOR AER 300ML*12 L1

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
GRIFFON DEVMOR AER 300ML*12 L1
Product Code
1235612

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Metal-working product

Manufacturers & Suppliers

B

Bison International

manufacturer

Dr.A.F.Philipsstraat 9 NL-4462 EW Goes PO Box 160 NL-4460 AD Goes

+31 88 3235700

Emergency Contacts

Emergency Contact

+31 88 3235700

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H222 Extremely flammable aerosol. Pressurised container: May burst if heated.
H319 Causes serious eye irritation.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P261 Avoid breathing spray.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.
P501 Dispose of contents/container in accordance with national regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Metal working product

Chemical Name CAS Number Concentration Hazardous
acetone EC: 200-662-2 67-64-1 10 - 25% Yes
propan-2-ol EC: 200-661-7 67-63-0 10 - 25% Yes
propane EC: 200-827-9 74-98-6 10 - 25% Yes
isobutane EC: 200-857-2 75-28-5 2.5 - 10% Yes
butane EC: 203-448-7 106-97-8 25 - 50% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Generally the product does not irritate the skin.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

Do not induce vomiting; call for medical help immediately.

Immediate Medical Attention

Consult doctor in case of complaints (inhalation), if symptoms persist (eye contact), or immediately (ingestion).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Dispose contaminated material as waste according to item 13.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke. Do not pierce or burn, even after use.

Storage

Observe official regulations on storing packagings with pressurised containers. Keep receptacle tightly sealed.

Fire prevention

Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact of a maximum of 15 minutes gloves made of the following materials are suitable: PVC or PE gloves

Eyes

Tightly sealed goggles

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Aerosol
Physical State Data
aerosol
State Under Standard Conditions
---
Appearance
---
Colour
According to product specification
Colour Intensity
---
Form
Aerosol
Odor
Characteristic
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Undetermined.
Boiling Point
-44 °C
Flash Point
-97 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable.
Vapor Pressure
8300 hPa
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
0.811 g/cm³
Flammability
Not applicable.
Upper Explosive Limit
13.0 Vol %
Lower Explosive Limit
1.5 Vol %
Explosive Limits
---
Auto Ignition Temperature
365 °C
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used according to specifications.

Incompatible

No further relevant information available.

Decomposition

Danger of forming toxic pyrolysis products.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Aquatic toxicity: No further relevant information available.

No further relevant information available regarding aquatic toxicity.

12.2 Persistence and degradability

No further relevant information available.

12.3 Bioaccumulative potential

No further relevant information available.

No further relevant information available.

12.4 Mobility in soil

No further relevant information available.

12.5 Results of PBT and vPvB assessment

- PBT: Not applicable. - vPvB: Not applicable.

The substance is not considered to be PBT or vPvB.

12.6 Other adverse effects

No further relevant information available.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

Disposal

Must not be disposed together with household garbage.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2
Packing Group
Void
ADR

Warning: Gases.

IMDG

Warning: Gases. Stowage Code: SW1 Protected from sources of heat. SW22 For AEROSOLS with a maximum capacity of 1 litre: Category A. For AEROSOLS with a capacity above 1 litre: Category B. For WASTE AEROSOLS: Category C, Clear of living quarters. Segregation Code: SG69 For AEROSOLS with a maximum capacity of 1 litre: Segregation as for class 9. Stow 'separated from' class 1 except for division 1.4. For AEROSOLS with a capacity above 1 litre: Segregation as for the appropriate subdivision of class 2. For WASTE AEROSOLS: Segregation as for the appropriate subdivision of class 2.

IATA

Warning: Gases.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for GRIFFON DEVMOR AER 300ML*12 L1?

The signal word is danger.

What is the physical form of GRIFFON DEVMOR AER 300ML*12 L1?

GRIFFON DEVMOR AER 300ML*12 L1 is a aerosol with according to product specification color. It has characteristic odor.

What is GRIFFON DEVMOR AER 300ML*12 L1 used for?

Metal-working product

What are the hazard statements for GRIFFON DEVMOR AER 300ML*12 L1?

This substance has 3 hazard statements:

  • H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.

What is the melting point of GRIFFON DEVMOR AER 300ML*12 L1?