Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Adipic acid
- Product Code
- 2639
- Chemical Name
- Adipic acid
Regulatory Identifiers
- CAS Number
- 124-04-9 Check regulations →
- EC Number
- 204-673-3 Check regulations →
- REACH No.
- 01-2116457561-38-XXXX
Identified Uses
Industrial use Chemical analytics Laboratory chemical
Uses advised against
The product is not intended for use by consumers For professional users only
Manufacturers & Suppliers
Th. Geyer GmbH & Co. KG
manufacturer
Dornierstr. 4 – 6 D-71272 Renningen
+49(0)7159-1637-0
http://www.thgeyer.de
Emergency Contacts
National Poisons Information Service
(00 44) 87 06 00 62 66
NHS 111
111
NHS 24
111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Adipic acid EC: 204-673-3 | 124-04-9 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person from danger zone. Supply fresh air; consult doctor in case of complaints.
Wash with plenty of soap and water, take off soiled clothes and shoes. After prolonged contact (accidental/forced) or any signs of skin changes, consult a doctor.
Symptoms: redness or other signs of inflammation
Rinse out opened eye for several minutes under running water. Consult an ophthalmologist immediately. Remove contact lenses.
Rinse out mouth and then drink plenty of water. If symptoms persist consult doctor.
Immediate Medical Attention
Consult an ophthalmologist immediately (for eye contact). Consult doctor in case of complaints (inhalation, skin, or ingestion).
Medical Treatment
Information for doctor: Please observe safety data sheet/label.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions. Use carbon dioxide, extinguishing powder, water spray or alcohol-resistant foam.
Water with full jet.
Combustible. Vapours are heavier than air and spread over the ground. Formation of toxic gases is possible during heating or in case of fire. Explosive mixtures with air are possible with strong heating.
Do not inhale explosion gases or combustion gases.
Firefighter Protection
Wear self-contained respiratory protective device. Do not inhale explosion gases or combustion gases.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Clear the danger zone.
Do not allow to enter sewers/surface or ground water.
Pick up mechanically.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Apply the general protective and hygienic measures when handling chemicals.
Store in cool, dry conditions in well sealed receptacles. Protect from heat and direct sunlight. Protect from humidity and water.
Apply the general protective and hygienic measures when handling chemicals.
Substance itself does not burn, adapt extinguishing measures to surroundings
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
Protective gloves. Labsolute®Nitril green. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: NBR: Acrylonitrile butadiene rubber. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. Level 6 for applications > 480 min
Safety glasses
Required when vapours/aerosols/dusts occur. Filter P2
Protective work clothing (e. g. safety shoes EN ISO 20345, long-sleeved protective working garments).
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable when stored and handled properly.
No further relevant information available.
No dangerous reactions known.
No decomposition if used according to specifications.
Avoid contact with other chemicals.
In case of fire: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance is not classified as PBT or vPvB.
12.6 Endocrine disrupting properties
The product does not contain substances with endocrine disrupting properties.
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Observe local (country-specific) regulations and laws.
Must not be disposed together with household garbage. Chemicals must be disposed of in accordance with the respective national regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Safety data sheet according to UK REACH
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Adipic acid?
The signal word is warning.
What is the physical form of Adipic acid?
Adipic acid is a solid with not determined. color. It has characteristic odor.
What is Adipic acid used for?
Industrial use Chemical analytics Laboratory chemical
What are the hazard statements for Adipic acid?
This substance has 1 hazard statement:
- H319: Causes serious eye irritation.
What is the melting point of Adipic acid?
The melting point is 150–153 °C and the boiling point is 330 °C.