Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE PE 3162 EPOXY HARDENER
- Product Code
- 39960
- Synonyms
- Loctite® Encap® 3162 Epoxy
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Epoxy Hardener
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS06
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N-Aminoethylpiperazine | 140-31-8 | 30 - 60% | Yes |
| 4-nonylphenol, branched | 84852-15-3 | 30 - 60% | Yes |
Notes
* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Remove contaminated clothing and footwear. Immediately flush skin with plenty of water (using soap, if available). Get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get immediate medical attention.
Immediate Medical Attention
Get medical attention (for inhalation, skin, and eye contact). Get immediate medical attention (for ingestion).
Medical Treatment
Not available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Not available.
Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel. Evacuate and ventilate spill area.
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up spilled material and place in a closed container for disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
LOCTITE EA E-30CL B HARDENER
---
EPOXY HARDENER
UFI: TONE-R380-100M-R44W
LOCTITE EA 210209 EPOXY
---
LOCTITE EA 210232 EPOXY
---
LOCTITE EA 3324B EPOXY 2K HARDENER known as Loctite E3324 B_0,56Kg Stick
---
LOCTITE AA H3151 B HARDENER known as SPEEDBONDER H3151 400 ML PART B
---
LOCTITE 315
---
LOCTITE EA 0151 B HARDENER known as LOCTITE 0151 3.3oz KIT PTB
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Do not taste or swallow. Use only with adequate ventilation. Keep container closed.
Keep container tightly closed and in a cool, well-ventilated place away from incompatible materials. Keep away from heat, spark and flame. Store in original container until ready to use.
Wash thoroughly after handling.
Keep away from heat, spark and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use local exhaust ventilation if the potential for airborne exposure exists.
Use chemical resistant, impermeable clothing including gloves
Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists.
Use a NIOSH approved respirator if ventilation is inadequate.
Use chemical resistant, impermeable clothing including gloves and either an apron or body suit to prevent skin contact.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing.
Keep away from heat, ignition sources and incompatible materials.
Strong acids and oxidizing agents. This product slowly corrodes copper, aluminum, zinc and galvanized surfaces.
Oxides of carbon. Oxides of nitrogen. Ammonia. Toxic fumes. Irritating vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Follow all local, state, federal and provincial regulations for disposal.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3267
- Shipping Name
- Corrosive liquid, basic, organic, n.o.s. (Aminoethylpiperazine, Nonylphenol)
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is LOCTITE PE 3162 EPOXY HARDENER known by?
LOCTITE PE 3162 EPOXY HARDENER is also known as: Loctite® Encap® 3162 Epoxy
What is the hazard signal word for LOCTITE PE 3162 EPOXY HARDENER?
The signal word is danger.
What is the physical form of LOCTITE PE 3162 EPOXY HARDENER?
LOCTITE PE 3162 EPOXY HARDENER is a liquid with amber color. It has ammoniacal odor.
What is the solubility of LOCTITE PE 3162 EPOXY HARDENER?
Soluble
What is LOCTITE PE 3162 EPOXY HARDENER used for?
Epoxy Hardener
What are the hazard statements for LOCTITE PE 3162 EPOXY HARDENER?
This substance has 5 hazard statements:
- H302: HARMFUL IF SWALLOWED.
- H311: TOXIC IN CONTACT WITH SKIN.
- H314: CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H361: SUSPECTED OF DAMAGING FERTILITY OR THE UNBORN CHILD.
What is the melting point of LOCTITE PE 3162 EPOXY HARDENER?
The melting point is Not available. and the boiling point is Not determined.