Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- mFreSR™
- Product Form
- Mixture
- Product Code
- DX20937
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory reagent
Uses advised against
No information available
Manufacturers & Suppliers
STEMCELL Technologies SARL
manufacturer
40 Rue des Berges, Miniparc Polytec, Bâtiment Sirocco, 38000 Grenoble, France
+33 (0) 4 76 04 75 30
STEMCELL Technologies Germany GmbH
manufacturer
Stolberger Str. 200, 50933, Köln, Germany
+33 (0) 4 76 04 75 30
STEMCELL Technologies UK Ltd.
manufacturer
Building 7100, Cambridge Research Park, Beach Drive, Waterbeach, Cambridge, UK, CB25 9TL
+33 (0) 4 76 04 75 30
Emergency Contacts
Emergency Contact
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| dimethyl sulfoxide EC: 200-664-3 | 67-68-5 | 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Get medical attention immediately if symptoms occur.
Wash off immediately with soap and plenty of water for at least 15 minutes. Get medical attention if irritation develops and persists.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep eye wide open while rinsing. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists.
Clean mouth with water and drink afterwards plenty of water. Never give anything by mouth to an unconscious person. Do NOT induce vomiting. Call a physician.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
No information available.
No information available.
Firefighter Protection
Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with skin, eyes or clothing. Ensure adequate ventilation. Use personal protective equipment as required.
Prevent further leakage or spillage if safe to do so.
Take up mechanically, placing in appropriate containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes or clothing. Do not eat, drink or smoke when using this product. Take off contaminated clothing and wash before reuse.
Store in accordance with information listed on the Product Information Sheet (PIS).
Wear suitable gloves and eye/face protection. Do not eat, drink or smoke when using this product.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear suitable gloves. Impervious gloves.
No special protective equipment required.
No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required.
Wear suitable protective clothing. Long sleeved clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended transport or storage conditions.
No information available.
None under normal processing.
None known based on information supplied.
Strong acids. Strong oxidizing agents.
None known based on information supplied.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
Contains 0 % of components with unknown hazards to the aquatic environment.
12.1. Toxicity
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
12.4. Mobility in soil
No information available.
12.5. Results of PBT and vPvB assessment
The substance is not PBT / vPvB.
12.6. Other adverse effects
No information available.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.
Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Safety, health and environmental regulations/legislation specific for the substance or mixture
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for mFreSR™?
The signal word is warning.
What is the physical form of mFreSR™?
mFreSR™ is a liquid appearing as clear with orange color. It has no data available. odor.
What is the solubility of mFreSR™?
No data available
What is mFreSR™ used for?
Laboratory reagent
What are the hazard statements for mFreSR™?
This substance has 1 hazard statement:
- H315: Causes skin irritation
What is the melting point of mFreSR™?
The melting point is No data available and the boiling point is No data available.