Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ammonia, anhydrous
- Product Form
- Substance
- Product Code
- 000010021772
- Chemical Name
- Ammonia, anhydrous
Regulatory Identifiers
- CAS Number
- 7664-41-7 Check regulations →
- EC Number
- 231-635-3 Check regulations →
- REACH No.
- 01-2119488876-14
Identified Uses
Use in explosives Casting operations Refrigerant Formulation of mixtures with gas in pressure receptacles. Freezing, chilling, and packaging of foodstuffs. Using gas as feedstock in chemical processes. Using gas alone or in mixtures for the calibration of analysis equipment. Using gas for metal treatment. Electronic component manufacture Industrial and professional. Perform risk assessment prior to use. Manufacture of fertilisers and nitrogen compounds, Nitric acid Cleaning/washing agents Manufacture of plastics Raw material for pharmaceutical products Water treatment Laboratory use
Uses advised against
Consumer use. Uses other than those listed above are not supported, contact your supplier for more information on other uses.
Manufacturers & Suppliers
Linde Gas Benelux B.V.
national supplier
Havenstraat 23, NL 3115 HC Schiedam, Netherlands
+31 (0) 88 2626262
Emergency Contacts
National Poison Information Centre, Utrecht
+31 (0) 30 2748888
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
GHS05
GHS06
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ammonia, anhydrous EC: 231-635-3 | 7664-41-7 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.
Symptoms: Cough, shortness of breath, headache, nausea. Material is destructive to tissue of the mucuous membranes and upper respiratory tract.
Remove contaminated clothing. Drench affected area with water for at least 15 minutes. In case of frostbite spray with water for at least 15 minutes. Apply a sterile dressing. Obtain medical assistance.
Symptoms: May cause severe chemical burns to skin.
Immediately flush eyes thoroughly with water for at least 15 minutes.
Symptoms: May cause severe chemical burns to cornea.
Ingestion is not considered a potential route of exposure.
Immediate Medical Attention
Obtain medical assistance.
Medical Treatment
Treat with corticosteroid spray as soon as possible after inhalation.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam. Shutting off the source of the gas is the preferred method of control. Water spray or fog.
Do not use water jet to extinguish.
Exposure to fire may cause containers to rupture/explode.
Do not extinguish a leaking gas flame unless absolutely necessary. Spontaneous/explosive re- ignition may occur. Extinguish any other fire. Use fire control measures appropriate for the surrounding fire. Cool endangered receptacles with water spray jet from a protected position. If possible, stop flow of product. Use water spray or fog to knock down fire fumes if possible. Move containers away from the fire area if this can be done without risk.
Firefighter Protection
Wear gas tight chemically protective clothing in combination with self contained breathing apparatus. Standard EN 943-2: Protective clothing against liquid and gaseous chemicals, aerosols and solid particles. Gas-tight chemical protective suits for emergency teams. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Act in accordance with local emergency plan. Try to stop release. Evacuate area. Ensure adequate air ventilation. Eliminate ignition sources. Stay upwind. See section 8 of the SDS for more information on personal protective equipment.
Reduce vapour with fog or fine water spray. Try to stop release.
Hose down area with water. Wash contaminated equipment or sites of leaks with copious quantities of water.
Materials: water
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only lubricants and sealings approved for the specific gas service. Installation of a cross purge assembly between the container and the regulator is recommended. Purge system with dry inert gas (e.g. helium or nitrogen) before gas is introduced and when system is placed out of service. Assess the risk of potentially explosive atmospheres and the need for explosion-proof equipment. Purge air from system before introducing gas. Take precautionary measures against static discharge. Keep away from ignition sources (including static discharges). Consider the use of only non-sparking tools. Ensure equipment is adequately earthed. Avoid exposure, obtain special instructions before use. The product must be handled in accordance with good industrial hygiene and safety procedures. Only experienced and properly instructed persons should handle gases under pressure. Consider pressure relief device(s) in gas installations. Ensure the complete gas system was (or is regularily) checked for leaks before use. Do not smoke while handling product. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. Contact your gas supplier if in doubt. Avoid suck back of water, acid and alkalis. Do not breathe gas. Avoid release of product into work area. Refer to supplier's container handling instructions. Do not allow backfeed into the container. Protect containers from physical damage; do not drag, roll, slide or drop. When moving cylinders, even for short distances, use a cart (trolley, hand truck, etc.) designed to transport cylinders. Leave valve protection caps in place until the container has been secured against either a wall or bench or placed in a container stand and is ready for use. If user experiences any difficulty operating valve discontinue use and contact supplier. Never attempt to repair or modify container valves or safety relief devices. Damaged valves should be reported immediately to the supplier. Keep container valve outlets clean and free from contaminants particularly oil and water. Replace valve outlet caps or plugs and container caps where supplied as soon as container is disconnected from equipment. Close container valve after each use and when empty, even if still connected to equipment. Never attempt to transfer gases from one cylinder/container to another. Never use direct flame or electrical heating devices to raise the pressure of a container. Do not remove or deface labels provided by the supplier for the identification of the content of the container. Suck back of water into the container must be prevented. Open valve slowly to avoid pressure shock.
Keep container below 50℃ in a well ventilated place. Store containers in location free from fire risk and away from sources of heat and ignition. Keep away from combustible materials. Containers should be stored in the vertical position and properly secured to prevent them from falling over. Container valve guards or caps should be in place.
The product must be handled in accordance with good industrial hygiene and safety procedures. Do not smoke while handling product. Do not breathe gas. Avoid release of product into work area.
Keep away from ignition sources (including static discharges). Consider the use of only non-sparking tools. Ensure equipment is adequately earthed.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate general and local exhaust ventilation. Product to be handled in a closed system. Consider the use of a work permit system e.g. for maintenance activities. Gas detectors should be used when toxic gases may be released. Systems under pressure should be regularily checked for leakages. Ensure exposure is below occupational exposure limits (where available).
Wear working gloves when handling gas containers. Wear chemically resistant protective gloves. Standard EN 374 - Protective gloves against chemicals. Standard EN 388 - Protective gloves against mechanical risks, performance level 1 or higher. Standard EN 511 - Cold insulating gloves, performance level 1 or higher. Recommended types include insulated gauntlets or gloves specifically selected to prevent liquid penetration and ingress of cryogenic liquids and to provide mechanical resistance. Permeation time: minimum >30min short term exposure: material / thickness Chloroprene rubber (Neoprene®) (CR) / 0,5 [mm]. Permeation time: minimum >480min long term exposure : material / thickness Butyl rubber (IIR) / 0,7 [mm]. Consult glove manufacturer's product information on material suitability and material thickness. The breakthrough time of the selected gloves must be greater than the intended use period.
Wear goggles and a face shield when transfilling or breaking transfer connections. Standard EN 166 - Personal eye-protection - specifications
Recommended: Filter K (green). Keep self contained breathing apparatus readily available for emergency use. Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems. Gas filters may be used if all surrounding conditions e.g. type and concentration of the contaminant(s) and duration of use are known. Use gas filters with full face mask, where exposure limits may be exceeded for a short-term period, e.g. connecting or disconnecting containers. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. Gas filters do not protect against oxygen deficiency. Standard EN 14387 - Gas filter(s), combined filter(s) and standard EN136, full face masks .
Keep suitable chemically resistant protective clothing readily available for emergency use. Standard EN943-1 - Full protective suits against liquid, solid and gaseous chemicals. Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.
Refer to local regulations for restriction of emissions to the atmosphere. See section 13 for specific methods for waste gas treatment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No reactivity hazard other than the effects described in sub-sections below.
Can form explosive mixture with air. May react violently with oxidants.
Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Avoid moisture in installation systems.
Water, acids, air, oxidisers
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
The substance is classified as very toxic to aquatic life with long-lasting effects.
12.1. Toxicity
12.2. Persistence and degradability
12.2. Persistence and degradability
The substance is readily biodegradable and unlikely to persist.
12.3. Bioaccumulative potential
The bioaccumulative potential is not applicable for this substance as it is an inorganic gas mixture; no data is available for assessment.
12.4. Mobility in soil
Because of its high volatility, the product is unlikely to cause ground or water pollution. Partition into soil is unlikely.
12.5. Results of PBT and vPvB assessment
Not classified as PBT or vPvB.
12.6. Endocrine disrupting properties
Other adverse effects
12.7. Other adverse effects
May cause pH changes in aqueous ecological systems. No effect on the ozone layer. No known effects on global warming.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Toxic and corrosive gases formed during combustion should be scrubbed before discharge to atmosphere. Gas may be scrubbed in sulphuric acid solution. Gas may be scrubbed in water.
Return unused product in original container to supplier.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1005
- Shipping Name
- AMMONIA, ANHYDROUS
- Transport Class
- 2.3 (8)
Avoid transport on vehicles where the load space is not separated from the driver's compartment, Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency, Before transporting product containers: - Ensure there is adequate ventilation, - Ensure that containers are firmly secured, - Ensure valve is closed and not leaking, - Ensure valve outlet cap nut or plug (where provided) is correctly fitted, - Ensure valve protection device (where provided) is correctly fitted.
Avoid transport on vehicles where the load space is not separated from the driver's compartment, Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency, Before transporting product containers: - Ensure there is adequate ventilation, - Ensure that containers are firmly secured, - Ensure valve is closed and not leaking, - Ensure valve outlet cap nut or plug (where provided) is correctly fitted, - Ensure valve protection device (where provided) is correctly fitted.
Avoid transport on vehicles where the load space is not separated from the driver's compartment, Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency, Before transporting product containers: - Ensure there is adequate ventilation, - Ensure that containers are firmly secured, - Ensure valve is closed and not leaking, - Ensure valve outlet cap nut or plug (where provided) is correctly fitted, - Ensure valve protection device (where provided) is correctly fitted.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ammonia, anhydrous?
The signal word is danger.
What is the physical form of Ammonia, anhydrous?
Ammonia, anhydrous is a gas with colourless. color. It has ammoniacal. odor.
What is Ammonia, anhydrous used for?
Use in explosives Casting operations Refrigerant Formulation of mixtures with gas in pressure receptacles. Freezing, chilling, and packaging of foodstuffs. Using gas as feedstock in chemical processes. Using gas alone or in mixtures for the calibration of analysis equipment. Using gas for metal treatment. Electronic component manufacture Industrial and professional. Perform risk assessment prior to use. Manufacture of fertilisers and nitrogen compounds, Nitric acid Cleaning/washing agents Manufacture of plastics Raw material for pharmaceutical products Water treatment Laboratory use
What are the hazard statements for Ammonia, anhydrous?
This substance has 5 hazard statements:
- H221: Flammable gas.
- H280: Contains gas under pressure; may explode if heated.
- H314: Causes severe skin burns and eye damage.
- H331: Toxic if inhaled.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of Ammonia, anhydrous?
The melting point is -77.7 ℃ and the boiling point is -33 ℃.