Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Carrier RNA
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory Use
Manufacturers & Suppliers
Omega Bio-tek
manufacturer
400 Pinnacle Way, Suite 450 Georgia 30071 United States
+1 770 931 8400
http://www.omegabiotek.com
Emergency Contacts
CHEMTREC
+1 800 424 9300
CHEMTREC
+1 703 527 3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| polyadenylic acid; polyuridylic acid potassium salt | 24936-38-7 | 0.1% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If fumes, aerosols or combustion products are inhaled remove from contaminated area. Other measures are usually unnecessary.
Flush skin and hair with running water (and soap if available). Seek medical attention in event of irritation.
Wash out immediately with water. If irritation continues, seek medical attention. Removal of contact lenses after an eye injury should only be undertaken by skilled personnel.
Immediately give a glass of water. First aid is not generally required. If in doubt, contact a Poisons Information Centre or a doctor.
Immediate Medical Attention
Seek medical attention in event of irritation (skin), if irritation continues (eyes), or if in doubt (ingestion).
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
There is no restriction on the type of extinguisher which may be used. Use extinguishing media suitable for surrounding area.
Non combustible. Not considered a significant fire risk, however containers may burn.
Use water delivered as a fine spray to control fire and cool adjacent area. Do not approach containers suspected to be hot. Cool fire exposed containers with water spray from a protected location. If safe to do so, remove containers from path of fire. Equipment should be thoroughly decontaminated after use.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Clear area of personnel and move upwind. Alert Fire Brigade and tell them location and nature of hazard. Control personal contact with the substance, by using protective equipment. Prevent spillage from entering drains, sewers or water courses. Recover product wherever possible. Put residues in labelled containers for disposal. If contamination of drains or waterways occurs, advise emergency services.
Clean up all spills immediately. Avoid breathing vapours and contact with skin and eyes. Control personal contact with the substance, by using protective equipment. Contain and absorb spill with sand, earth, inert material or vermiculite. Wipe up. Place in a suitable, labelled container for waste disposal.
Clear area of personnel and move upwind. Alert Fire Brigade and tell them location and nature of hazard. Control personal contact with the substance, by using protective equipment. Prevent spillage from entering drains, sewers or water courses. Recover product wherever possible. Put residues in labelled containers for disposal. If contamination of drains or waterways occurs, advise emergency services.
See section 12
Clean up all spills immediately. Wipe up. Recover product wherever possible.
Materials: sand, earth, inert material or vermiculite
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Limit all unnecessary personal contact. Wear protective clothing when risk of exposure occurs. Use in a well-ventilated area. Avoid contact with incompatible materials. When handling, DO NOT eat, drink or smoke. Keep containers securely sealed when not in use. Avoid physical damage to containers. Always wash hands with soap and water after handling. Work clothes should be laundered separately. Use good occupational work practice. Observe manufacturer's storage and handling recommendations contained within this SDS. Atmosphere should be regularly checked against established exposure standards to ensure safe working conditions are maintained.
Polyethylene or polypropylene container. Packing as recommended by manufacturer. Check all containers are clearly labelled and free from leaks.
When handling, DO NOT eat, drink or smoke. Always wash hands with soap and water after handling. Work clothes should be laundered separately.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Well-designed engineering controls can be highly effective in protecting workers and will typically be independent of worker interactions to provide this high level of protection. The basic types of engineering controls are: Process controls which involve changing the way a job activity or process is done to reduce the risk. Enclosure and/or isolation of emission source which keeps a selected hazard 'physically' away from the worker and ventilation that strategically 'adds' and 'removes' air in the work environment. Ventilation can remove or dilute an air contaminant if designed properly. The design of a ventilation system must match the particular process and chemical or contaminant in use. Employers may need to use multiple types of controls to prevent employee overexposure. General exhaust is adequate under normal operating conditions. If risk of overexposure exists, wear SAA approved respirator. Correct fit is essential to obtain adequate protection. Provide adequate ventilation in warehouse or closed storage areas.
Wear general protective gloves, eg. light weight rubber gloves. The selection of suitable gloves does not only depend on the material, but also on further marks of quality which vary from manufacturer to manufacturer. Where the chemical is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time for substances has to be obtained from the manufacturer of the protective gloves and has to be observed when making a final choice. Select gloves tested to a relevant standard (e.g. Europe EN 374, US F739, AS/NZS 2161.1 or national equivalent). When prolonged or frequently repeated contact may occur, a glove with a protection class of 5 or higher (breakthrough time greater than 240 minutes according to EN 374, AS/NZS 2161.10.1 or national equivalent) is recommended. When only brief contact is expected, a glove with a protection class of 3 or higher (breakthrough time greater than 60 minutes according to EN 374, AS/NZS 2161.10.1 or national equivalent) is recommended. For general applications, gloves with a thickness typically greater than 0.35 mm, are recommended.
Safety glasses with side shields; Chemical goggles. [AS/NZS 1336 or national equivalent]
If risk of overexposure exists, wear SAA approved respirator. Correct fit is essential to obtain adequate protection.
Overalls. Barrier cream.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Product is considered stable
See section 7
hazardous polymerisation will not occur.
See section 7
See section 7
See section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Toxicity
No toxicity data available for the ingredients.
Persistence and degradability
No data available for all ingredients.
Bioaccumulative potential
No data available for all ingredients.
Mobility in soil
No data available for all ingredients.
Results of PBT and vPvB assessment
Endocrine disrupting properties
Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Legislation addressing waste disposal requirements may differ by country, state and/or territory. Each user must refer to laws operating in their area. In some areas, certain wastes must be tracked. A Hierarchy of Controls seems to be common - the user should investigate: ► Reduction ► Reuse ► Recycling ► Disposal (if all else fails) This material may be recycled if unused, or if it has not been contaminated so as to make it unsuitable for its intended use. If it has been contaminated, it may be possible to reclaim the product by filtration, distillation or some other means. Shelf life considerations should also be applied in making decisions of this type. Note that properties of a material may change in use, and recycling or reuse may not always be appropriate.
Recycle wherever possible. Consult manufacturer for recycling options or consult local or regional waste management authority for disposal if no suitable treatment or disposal facility can be identified. Dispose of by: burial in a land-fill specifically licensed to accept chemical and / or pharmaceutical wastes or incineration in a licensed apparatus (after admixture with suitable combustible material).
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
polyadenylic acid/ polyuridylic acid potassium salt is found on the following regulatory lists: Not Applicable
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Carrier RNA?
The signal word is no signal word.
What is the physical form of Carrier RNA?
Carrier RNA is a liquid appearing as not available . It has not available odor.
What is Carrier RNA used for?
Laboratory Use
What is the melting point of Carrier RNA?
The melting point is Not Available and the boiling point is Not Available.