Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Nonflammable Anesthetic Calibration Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen / Sevoflurane
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Synthetic/Analytical chemistry.
Manufacturers & Suppliers
Airgas USA, LLC and its affiliates
manufacturer
259 North Radnor-Chester Road, Suite 100, Radnor, PA 19087-5283
1-610-687-5253
Emergency Contacts
Emergency Contact
1-866-734-3438
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Nitrogen | 7727-37-9 | 46.5 - 96% | No |
| oxygen | 7782-44-7 | 1 - 23.5% | No |
| Carbon Dioxide | 124-38-9 | 2 - 20% | No |
| sevoflurane | 28523-86-6 | 1 - 10% | No |
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours.
Symptoms: Exposure to decomposition products may cause a health hazard. Serious effects may be delayed following exposure.
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms: Contact with rapidly expanding gas may cause burns or frostbite.
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.
Symptoms: Contact with rapidly expanding gas may cause burns or frostbite.
As this product is a gas, refer to the inhalation section.
Symptoms: As this product is a gas, refer to the inhalation section.
Immediate Medical Attention
In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours.
Medical Treatment
No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use an extinguishing agent suitable for the surrounding fire.
None known.
Contains gas under pressure. In a fire or if heated, a pressure increase will occur and the container may burst or explode.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Contact supplier immediately for specialist advice. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Avoid breathing gas. Provide adequate ventilation.
Immediately contact emergency personnel. Stop leak if without risk.
Immediately contact emergency personnel. Stop leak if without risk.
Ensure emergency procedures to deal with accidental gas releases are in place to avoid contamination of the environment.
Related Products
Similar products with comparable safety profiles
Nonflammable Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen
---
Nonflammable Gas Mixture: Argon / Carbon Dioxide / Helium
---
Nonflammable Lung Diffusion Gas Mixture: Acetylene / Carbon Monoxide / Methane / Neon / Nitrogen / Oxygen
---
NON-FLAMMABLE GAS MIXTURE Containing One or More of the Following Components in a Nitrogen Balance Gas: Carbon Monoxide, 0.0005 – 1.0%; Hydrogen, 0 – 2.0%; Methane, 0 – 2.5%; Oxygen, 0 – 23.5%
---
Precision Calibration Gas Mixture
---
NON-FLAMMABLE GAS MIXTURE
---
Oxidizing Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen
---
Mixture 10% CO2 in N2
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Contains gas under pressure. Avoid contact with eyes, skin and clothing. Avoid breathing gas. Empty containers retain product residue and can be hazardous. Do not puncture or incinerate container. Use equipment rated for cylinder pressure. Close valve after each use and when empty. Protect cylinders from physical damage; do not drag, roll, slide, or drop. Use a suitable hand truck for cylinder movement.
Store in accordance with local regulations. Store in a segregated and approved area. Store away from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10). Keep container tightly closed and sealed until ready for use. Cylinders should be stored upright, with valve protection cap in place, and firmly secured to prevent falling or being knocked over. Cylinder temperatures should not exceed 52 °C (125 °F).
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.
Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur. Hazardous polymerization will not occur.
No specific data.
Not considered to be reactive according to our database.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Toxicity
Persistence and degradability
Bioaccumulative potential
Mobility in soil
Results of PBT and vPvB assessment
Endocrine disrupting properties
Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1956
- Shipping Name
- COMPRESSED GAS, N.O.S. (nitrogen, oxygen)
- Transport Class
- 2.2
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Nonflammable Anesthetic Calibration Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen / Sevoflurane?
The signal word is warning.
What is the physical form of Nonflammable Anesthetic Calibration Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen / Sevoflurane?
Nonflammable Anesthetic Calibration Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen / Sevoflurane is a gas. with not available. color. It has not available. odor.
What is the solubility of Nonflammable Anesthetic Calibration Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen / Sevoflurane?
Not available.
What is Nonflammable Anesthetic Calibration Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen / Sevoflurane used for?
Synthetic/Analytical chemistry.
What are the hazard statements for Nonflammable Anesthetic Calibration Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen / Sevoflurane?
This substance has 2 hazard statements:
- H280: Contains gas under pressure; may explode if heated.
- H335: May increase respiration and heart rate.
What is the melting point of Nonflammable Anesthetic Calibration Gas Mixture: Carbon Dioxide / Nitrogen / Oxygen / Sevoflurane?
The melting point is -210.01°C (-346°F) This is based on data for the following ingredient: nitrogen. Weighted average: -211.66°C (-349°F) .