01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Precision Calibration Gas Mixture
Product Form
Calibration gas mixture
Product Code
G-33116

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Used for calibration of gas measuring devices.

Uses advised against

Not suitable for human consumption.

Manufacturers & Suppliers

G

Gasco Affiliates, LLC

manufacturer

320 Scarlett Blvd., Oldsmar, FL 34677

(800) 910-0051

Emergency Contacts

CHEMTREC

1-800-424-9300

24 hours

CHEMTREC

1-703-527-3887

24 hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Press. Gas H280

GHS Pictograms

GHS04 - Compressed gas

GHS04

Hazard Statements

H280 Contains gas under pressure; may explode if heated.

Precautionary Statements

P410 + P403 Protect from sunlight. Store in a well-ventilated place.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with non-hazardous additions.

Chemical Name CAS Number Concentration Hazardous
Nitrogen 7727-37-9 76.16 - 80.499% Yes
Oxygen 7782-44-7 19.5 - 23.49% Yes
Nitrous Oxide 10024-97-2 0.001 - 0.35% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Consult doctor if symptoms persist. In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Generally the product does not irritate the skin. Immerse frostbite in cool-warm water and seek medical attention. Wash with soap and water. If skin irritation occurs, consult a doctor.

Symptoms: In cases of contact with liquified material, frostbite may occur.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

If swallowed and symptoms occur, consult a doctor.

Immediate Medical Attention

Consult doctor if symptoms persist.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire fighting measures that suit the environment.

Specific hazards

Closed containers may explode when exposed to extreme heat. This gas mixture is not flammable; however, containers, when involved in fire, may rupture or burst in the heat of the fire.

Instructions

Use water spray to cool fire-exposed containers.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand (NIOSH approved or equivalent) and full protective gear to prevent contact with skin and eyes.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Treat any fumes as toxic. Keep people at a distance.

Environmental

Inform authorities in case of gas release.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace.

Storage

Store in a cool location. Cylinders should be firmly secured to prevent falling or being knocked over. Cylinders must be protected from the environment, and preferably kept at room temperature. Cylinders should be stored in dry, well-ventilated areas, away from sources of heat, ignition, and direct sunlight. Protect cylinders against physical damage. Full and empty cylinders should be segregated. Use a "first-on, first-out" inventory system to prevent full containers from being stored for long periods of time. Store in cool, dry conditions in well sealed receptacles.

Fire prevention

Do not spray on a naked flame or any incandescent material. Do not cut, grind or weld on container that contains or contained product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

All ventilation should be designed in accordance with OSHA standard (29 CFR 1910.94). Use mechanical (general) ventilation for storage areas. Use appropriate ventilation as required to keep Exposure Limits in Air below TLV & PEL limits.

Hands

Not required.

Eyes

Not necessary under normal conditions.

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure, use respiratory protective device that is independent of circulating air. Use suitable respiratory protective device in case of insufficient ventilation.

Skin/Body

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Dynamic Viscosity
Not determined.
Physical State Data
gas
Auto Ignition Temperature
Product is not self-igniting.
Molecular Weight
---
Partition Coefficient
Not determined.
Voc Content
---
Physical State
Gaseous
Ph
Not determined.
Kinematic Viscosity
Not determined.
Boiling Point
Not determined.
Flash Point
---
Colour Intensity
---
Cloud Point
---
Flammability
Not determined.
Bulk Density
---
Properties Status
---
Vapor Density
Not determined.
Upper Explosive Limit
Not determined.
Odor
Sweetish
Explosive Limits
---
Relative Evaporation Rate
---
Solubility In Fat
---
Lower Explosive Limit
Not determined.
Density
---
Crystallisation Point
---
Melting Point
Not determined.
Relative Density
Not determined.
Odor Threshold
Not determined.
Decomposition Temperature
Not determined.
State Under Standard Conditions
---
Vapor Pressure
Not determined.
Solubility In Water
Fully miscible.
Solidification Point
---
Softening Point
---
Freezing Point
---
Metal Corrosion
---
Evaporation Rate
Not applicable.
Colour
Clear, colorless
Solubility
---
Appearance
Clear, colorless
Form
Gaseous
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

Strong oxidizing agents.

Decomposition

Nitrogen Oxides (NOx).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Release all residual gas pressure in a well ventilated area. Verify the cylinder is completely empty (0 PSIG). Remove or cover any hazard labels. Return empty cylinder for recycling. NOTE: Check with the local waste authority before placing any gas cylinder into waste container for pickup. GASCO encourages the consumer to return all cylinders.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1956
Shipping Name
Compressed gas, n.o.s.
Transport Class
2.2
Packing Group
Non-Regulated Material
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Precision Calibration Gas Mixture?

The signal word is warning.

What is the physical form of Precision Calibration Gas Mixture?

Precision Calibration Gas Mixture is a gaseous appearing as clear, colorless with clear, colorless color. It has sweetish odor.

What is Precision Calibration Gas Mixture used for?

Used for calibration of gas measuring devices.

What are the hazard statements for Precision Calibration Gas Mixture?

This substance has 1 hazard statement:

  • H280: Contains gas under pressure; may explode if heated.

What is the melting point of Precision Calibration Gas Mixture?

The melting point is Not determined. and the boiling point is Not determined..