Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MOLYKOTE(R) 1000 SPRAY
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricants and additives
Uses advised against
None known.
Manufacturers & Suppliers
Dow Corning Europe S.A.
manufacturer
rue Jules Bordet - Parc Industriel - Zone C B-7180 Seneffe Belgium
Emergency Contacts
Dow Corning (Barry U.K. 24h)
+44 1446732350
24h
Dow Corning (Wiesbaden 24h)
+49 61122158
24h
Dow Corning (Seneffe 24h)
+32 64 888240
24h
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Butane EC: 203-448-7 | 106-97-8 | 53% | Yes |
| Naphtha (petroleum), hydrotreated heavy EC: 265-150-3 | 64742-48-9 | 15% | Yes |
| Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 | 64742-65-0 | 9.5% | No |
| Distillates (petroleum), solvent dewaxed light paraffinic; baseoil - unspecified EC: 265-159-2 | 64742-56-9 | 9.5% | No |
| Calcium fluoride EC: 232-188-7 | 7789-75-5 | 5% | No |
| Graphite EC: 231-955-3 | 7782-42-5 | 2.5% | No |
| Copper EC: 231-159-6 | 7440-50-8 | 1.8% | Yes |
| Polybutene | 9003-29-6 | 1.4% | No |
| Zinc EC: 231-175-3 | 7440-66-6 | 0.9% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Obtain medical attention immediately.
Symptoms: Vapours may cause drowsiness and dizziness.
Flush with water.
Flush with water.
Obtain medical attention.
Immediate Medical Attention
Obtain medical attention immediately for inhalation. Obtain medical attention for ingestion.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
On large fires use dry chemical, foam or water spray (fog). On small fires use carbon dioxide (CO2), dry chemical or water spray. Water can be used to cool fire exposed containers.
None known.
Pressurised container capable of exploding if heated. Toxic vapours are evolved.
Use water spray to keep fire exposed containers cool.
Firefighter Protection
A self-contained respirator and protective clothing should be worn.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Determine the need to evacuate or isolate the area according to your local emergency plan.
Do not empty into drains. Prevent from spreading or entering into drains, ditches or rivers by using sand, earth or other appropriate barriers.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe spray or mist. Do not spray on a naked flame or any incandescent material. Keep away from sources of ignition - no smoking. Do not breathe vapour. Avoid skin and eye contact.
Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50°C. Do not pierce or burn, even after use. Store in a flameproof, well ventilated area. Storage temperature: maximum 50 °C
Do not spray on a naked flame or any incandescent material. Keep away from sources of ignition - no smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ventilation : Refer to Section 7.1
Chemical protective gloves should be worn: Nitrile rubber. 4H(TM). Polyvinyl alcohol(PVA). Viton(TM). Regarding glove's breakthrough time, contact your chemical protective glove supplier.
Safety goggles should be worn.
A suitable respirator must be worn if the product is used in any circumstances where an aerosol or mist may be generated, such as during spraying or similar activities. Suitable respiratory protection should be worn if the product is used in large quantities, confined spaces or in other circumstances where the OEL may be approached or exceeded. Depending on the working conditions, wear a respiratory mask with filter(s) AXP or use a self-contained respirator. The choice of a filter type depends on the amount and type of chemical being handled in the workplace. Regarding filter characteristics, contact your respiratory protection supplier.
Wear impervious overalls in circumstances where significant skin contact can occur.
Refer to section 6 and 12.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal usage conditions.
None known.
None known.
Eliminate all possible sources of ignition.
Can react with strong oxidising agents.
Thermal breakdown of this product during fire or very high heat conditions may evolve the following decomposition products: Silica. Carbon oxides and traces of incompletely burned carbon compounds. Formaldehyde. Nitrogen products. Sulphur products. Toxic vapours of fluorinated compounds.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Ecotoxicity effects
12.2 Persistence and degradability
12.3 Bioaccumulation
12.4 Release to waters / Mobility in soil
May cause adverse effects on bacteria. If used as intended this product is not expected to reach waste water treatment plants.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MOLYKOTE(R) 1000 SPRAY?
The signal word is na: r-phrases.
What is the physical form of MOLYKOTE(R) 1000 SPRAY?
MOLYKOTE(R) 1000 SPRAY is a aerosol with brown color. It has solvent odor.
What is MOLYKOTE(R) 1000 SPRAY used for?
Lubricants and additives