Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RedSafe Nucleic Acid Staining Solution

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals

Uses advised against

Not available

Manufacturers & Suppliers

i

iNtRON Biotechnology, Inc.

manufacturer

#1011 Jungang Induspia V B/D, 137, Sagimakgol-ro, Jungwon-gu, Seongnam, Gyeonggi-do, 13202, Korea

+82-31-739-5737

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Mixture --- 0.1% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

When exposed to large amounts of steam and mist, move to fresh air. Take specific treatment if needed.

Skin contact

Flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Laundering enough contaminated clothing before reuse.

Eye contact

Do not rub your eyes. Immediately flush eyes with plenty of water for at least 15 minutes and call a doctor/physician.

Ingestion

Please be advised by doctor whether induction of vomit is demanded or not. Rinse your mouth with water immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dry chemical, carbon dioxide, regular foam extinguishing agent, spray

Unsuitable media

Avoid use of water jet for extinguishing

Specific hazards

Not available

Instructions

Cool containers with water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. Keep containers cool with water spray.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not touch spilled material. Stop leak if you can do it without risk. Handling the damaged containers or spilled material after wearing protective equipment.

Small spill

Appropriate container for disposal of spilled material collected.

Large spill

If large amounts have been spilled, inform the relevant authorities.

Environmental

Prevent runoff and contact with waterways, drains or sewers.

Cleanup methods

For disposal of spilled material in appropriate containers collected and clear surface.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Comply with all applicable laws and regulations for handling. Get the manual before use. Refer to Engineering controls and personal protective equipment. Operators should wear antistatic footwear and clothing. Minimize occurrence of dust and accumulation.

Storage

Keep in the original container.

Fire prevention

Operators should wear antistatic footwear and clothing.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

A system of local and/or general exhaust is recommended to keep employee exposures above the Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. The use of local exhaust ventilation is recommended to control emissions near the source.

Hands

Wear appropriate glove.

Eyes

Wear primary eye protection such as splash resistant safety goggles with a secondary protection face shield.

Respiratory

Under conditions of frequent use or heavy exposure, Respiratory protection may be needed. Respiratory protection is ranked in order from minimum to maximum. Consider warning properties before use. Dust, mist, fume-purifying respiratory protection. Any air-purifying respirator with a corpuscle filter of high efficiency. Any respiratory protection with a electromotion fan (for dust, mist, fume-purifying). Self-contained breathing apparatus with a corpuscle filter of high efficiency. For Unknown Concentration or Immediately Dangerous to Life or Health: Any supplied-air respirator with full facepiece and operated in a pressure-demand or other positive-pressure mode in combination with a separate escape supply. Any self-contained breathing apparatus with a full facepiece.

Skin/Body

Wear appropriate clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid
Colour
Dark orange
Colour Intensity
---
Form
---
Odor
Odorless
Odor Threshold
Not applicable
Ph
---
Melting Point
---
Boiling Point
---
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
Not applicable
Upper Explosive Limit
-/-
Lower Explosive Limit
-/-
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This material is stable under recommended storage and handling conditions.

Hazardous reactions

Hazardous Polymerization will not occur.

Avoid

Accumulation of electrostatic charges, Heating, Flames and hot surfaces

Incompatible

incompatible materials

Decomposition

May emit flammable vapour if involved in fire.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Persistence and degradability

- Persistence - [Water]: log Kow = -1.38

Degradability

Degradability: Not available Biodegradation: Not available

C. Bioaccumulative potential

Bioaccumulative potential: Not available

D. Mobility in soil

Not available

E. Other adverse effects

Not available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

reduction or stabilization by incineration or similar process. If water separation is possible, pre-process with Water separation process.

Disposal

Dispose by incineration.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

Local transport follows in accordance with Dangerous goods Safety Management Law. Package and transport follow in accordance with Department of Transportation (DOT) and other regulatory agency requirements.

IMDG

Local transport follows in accordance with Dangerous goods Safety Management Law. Package and transport follow in accordance with Department of Transportation (DOT) and other regulatory agency requirements.

IATA

Local transport follows in accordance with Dangerous goods Safety Management Law. Package and transport follow in accordance with Department of Transportation (DOT) and other regulatory agency requirements.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

National and/or international regulatory information

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RedSafe Nucleic Acid Staining Solution?

The signal word is no signal word.

What is the physical form of RedSafe Nucleic Acid Staining Solution?

RedSafe Nucleic Acid Staining Solution is a liquid appearing as liquid with dark orange color. It has odorless odor.

What is RedSafe Nucleic Acid Staining Solution used for?

Laboratory chemicals