Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Magnesium chloride, ultra dry
- Product Code
- 35707
- Chemical Name
- Magnesium chloride
Regulatory Identifiers
- CAS Number
- 7786-30-3 Check regulations →
- EC Number
- 232-094-6 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Thermo Fisher (Kandel) GmbH
manufacturer
Erlenbachweg 2, 76870 Kandel, Germany
+49 (0) 721 84007 280
http://www.alfa.com
Fisher Scientific AG
distributor
Neuhofstrasse 11, CH 4153 Reinach
+41 (0) 56 618 41 11
Emergency Contacts
Carechem 24
+44 (0) 1235 239 670
Poison Information Center Mainz
+49(0)6131/19240
Poison Information Center (VIZ)
+43 1 406 43 43
0-24 clock
Poison Information Center (VIZ)
+43 1 406 68 98
Monday to Friday, 8am to 4pm
Tox Info Suisse
145
24hr
Tox Info Suisse
+41-44 251 51 51
Chemtrec
0800 564 402
Chemtrec
+41-43 508 20 11
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Magnesium chloride EC: 232-094-6 | 7786-30-3 | 95% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Get medical attention immediately if symptoms occur.
Wash off immediately with plenty of water for at least 15 minutes. Get medical attention immediately if symptoms occur.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.
Water.
Reacts violently with water. Thermal decomposition can lead to release of irritating gases and vapors.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment as required. Avoid dust formation.
Should not be released into the environment. See Section 12 for additional Ecological Information.
Sweep up and shovel into suitable containers for disposal.
Related Products
Similar products with comparable safety profiles
Magnesium chloride
CAS: 7786-30-3
Magnesium chloride
CAS: 7786-30-3
Magnesium chloride
CAS: 7786-30-3
Magnesium chloride
CAS: 7786-30-3
Magnesium chloride, ACS
---
Magnesium chloride solution
---
Magnesium chloride hexahydrate
CAS: 7791-18-6
Magnesium chloride hexahydrate
CAS: 7791-18-6
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Ensure adequate ventilation. Avoid ingestion and inhalation. Avoid contact with skin, eyes or clothing. Avoid dust formation.
Keep containers tightly closed in a dry, cool and well-ventilated place. Store under an inert atmosphere.
Handle in accordance with good industrial hygiene and safety practice. When using do not eat, drink or smoke. Provide regular cleaning of equipment, work area and clothing.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement)
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted
Impervious gloves. Inspect gloves before use. observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. gloves with care avoiding skin contamination.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Hygroscopic.
None known, based on information available
Hazardous polymerization does not occur. None under normal processing.
Incompatible products. Excess heat. Avoid dust formation. Exposure to moist air or water. (When mixed with limited amount of water enough heat may be generated to cause frothing).
Strong oxidizing agents.
Magnesium oxides. Hydrogen chloride gas.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity Ecotoxicity effects
12.1. Toxicity Ecotoxicity effects
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
Inorganic substances do not require assessment in accordance with Annex XIII of the REACH Regulation.
12.6. Endocrine disrupting properties
This product does not contain any known or suspected endocrine disruptors.
12.7. Other adverse effects
This product does not contain any known or suspected substances related to Persistent Organic Pollutants or Ozone Depletion Potential.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with the European Directives on waste and hazardous waste. Dispose of in accordance with local regulations.
Waste is classified as hazardous.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Magnesium chloride, ultra dry?
The signal word is no signal word.
What is the physical form of Magnesium chloride, ultra dry?
Magnesium chloride, ultra dry is a solid appearing as white . It has odorless odor.
What is Magnesium chloride, ultra dry used for?
Laboratory chemicals.
What is the melting point of Magnesium chloride, ultra dry?
The melting point is 708 °C / 1306.4 °F and the boiling point is 1412 °C / 2573.6 °F @ 760 mmHg.