NextSDS Logo
Safety Data Sheet EN

Magnesium chloride, ultra dry

CAS 7786-30-3
EC 232-094-6

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Magnesium chloride, ultra dry
Product Code
35707
Chemical Name
Magnesium chloride

Regulatory Identifiers

CAS Number
7786-30-3 Check regulations →
EC Number
232-094-6 Check regulations →

Identified Uses

Laboratory chemicals.

Uses advised against

No Information available

Manufacturers & Suppliers

Thermo Fisher (Kandel) GmbH logo

Thermo Fisher (Kandel) GmbH

manufacturer

Erlenbachweg 2, 76870 Kandel, Germany

+49 (0) 721 84007 280

http://www.alfa.com

F

Fisher Scientific AG

distributor

Neuhofstrasse 11, CH 4153 Reinach

+41 (0) 56 618 41 11

Emergency Contacts

Carechem 24

+44 (0) 1235 239 670

Poison Information Center Mainz

+49(0)6131/19240

Poison Information Center (VIZ)

+43 1 406 43 43

0-24 clock

Poison Information Center (VIZ)

+43 1 406 68 98

Monday to Friday, 8am to 4pm

Tox Info Suisse

145

24hr

Tox Info Suisse

+41-44 251 51 51

Chemtrec

0800 564 402

Chemtrec

+41-43 508 20 11

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Magnesium chloride EC: 232-094-6 7786-30-3 95% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Get medical attention immediately if symptoms occur.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Get medical attention immediately if symptoms occur.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.

Unsuitable media

Water.

Specific hazards

Reacts violently with water. Thermal decomposition can lead to release of irritating gases and vapors.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Use personal protective equipment as required. Avoid dust formation.

Environmental

Should not be released into the environment. See Section 12 for additional Ecological Information.

Cleanup methods

Sweep up and shovel into suitable containers for disposal.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment/face protection. Ensure adequate ventilation. Avoid ingestion and inhalation. Avoid contact with skin, eyes or clothing. Avoid dust formation.

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place. Store under an inert atmosphere.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. When using do not eat, drink or smoke. Provide regular cleaning of equipment, work area and clothing.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source

Hands

Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement)

Eyes

Goggles (European standard - EN 166)

Respiratory

When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted

Skin/Body

Impervious gloves. Inspect gloves before use. observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. gloves with care avoiding skin contamination.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
White
Colour
---
Colour Intensity
---
Form
---
Odor
Odorless
Odor Threshold
No data available
Ph
No information available
Melting Point
708 °C / 1306.4 °F
Boiling Point
1412 °C / 2573.6 °F @ 760 mmHg
Flash Point
No information available
Freezing Point
---
Softening Point
No data available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable - Solid
Vapor Pressure
No data available
Vapor Density
Not applicable
Relative Density
---
Bulk Density
---
Density
---
Flammability
No information available
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
---
Solubility In Water
540 g/L (20°C)
Solubility In Fat
---
Molecular Weight
95.21
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Hygroscopic.

Reactivity

None known, based on information available

Hazardous reactions

Hazardous polymerization does not occur. None under normal processing.

Avoid

Incompatible products. Excess heat. Avoid dust formation. Exposure to moist air or water. (When mixed with limited amount of water enough heat may be generated to cause frothing).

Incompatible

Strong oxidizing agents.

Decomposition

Magnesium oxides. Hydrogen chloride gas.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity Ecotoxicity effects

Freshwater Fish: Pimephales promelas: EC50: 2.12 g/L:96H | EC50 : 1400 mg/L/24h | EC50: 2200 mg/L/72h

12.1. Toxicity Ecotoxicity effects

Ecotoxicity effects | Component | Microtox | M-Factor | | Magnesium chloride | EC50 Pseudomonas putida: EC50:26,14 g/L/h Photobacterium phosphoreum: EC50: 36,3 mg/L/30 min Photobacterium phosphoreum: EC50: 77,2 mg/L/24 h | |

12.2. Persistence and degradability

Persistence Soluble in water, Persistence is unlikely, based on information available. Degradability Not relevant for inorganic substances.

12.3. Bioaccumulative potential

Bioaccumulation is unlikely

12.4. Mobility in soil

The product is water soluble, and may spread in water systems. Will likely be mobile in the environment due to its water solubility. Highly mobile in soils

12.5. Results of PBT and vPvB assessment

In accordance with Annex XIII of the REACH Regulation, inorganic substances do not require assessment.

Inorganic substances do not require assessment in accordance with Annex XIII of the REACH Regulation.

12.6. Endocrine disrupting properties

Endocrine Disruptor Information This product does not contain any known or suspected endocrine disruptors

This product does not contain any known or suspected endocrine disruptors.

12.7. Other adverse effects

Persistent Organic Pollutant This product does not contain any known or suspected substance Ozone Depletion Potential This product does not contain any known or suspected substance

This product does not contain any known or suspected substances related to Persistent Organic Pollutants or Ozone Depletion Potential.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of in accordance with the European Directives on waste and hazardous waste. Dispose of in accordance with local regulations.

Disposal

Waste is classified as hazardous.

Waste Codes

Not product specific Waste codes are not product specific, but application specific. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Magnesium chloride, ultra dry?

The signal word is no signal word.

What is the physical form of Magnesium chloride, ultra dry?

Magnesium chloride, ultra dry is a solid appearing as white . It has odorless odor.

What is Magnesium chloride, ultra dry used for?

Laboratory chemicals.

What is the melting point of Magnesium chloride, ultra dry?

The melting point is 708 °C / 1306.4 °F and the boiling point is 1412 °C / 2573.6 °F @ 760 mmHg.