Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Thomsit R 710 PART A
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Floor adhesive Product is not intended for consumer use For professional users only.
Manufacturers & Suppliers
PCI Augsburg GmbH
manufacturer
PICCARDSTR. 11 86159 AUGSBURG
+4982159010
Emergency Contacts
GBK GmbH Global Regulatory Compliance
+49(0)6132-84463
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
No hazardous ingredients
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water.
Remove contact lenses. Keep eye wide open while rinsing.
Do not induce vomiting without medical advice. Rinse mouth with water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
water/water spray/water jet/carbon dioxide/sand/foam/alcohol resistant foam/chemical powder
Standard procedure for chemical fires.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No special environmental precautions required.
Wipe up with absorbent material (e.g. cloth, fleece).
Materials: cloth, fleece
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For personal protection see section 8. No special handling advice required. Follow standard hygiene measures when handling chemical products
Keep container tightly closed in a dry and well-ventilated areas and containers: place. Store in accordance with local regulations.
When using do not eat or drink. When using do not smoke.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Maintain air concentrations below occupational exposure standards. Ensure adequate ventilation, especially in confined areas. Ensure adequate ventilation. This can be achieved by local exhaust extraction or by general ventilation. (EN 689 - Methods for determining inhalation exposure). This applies in particular to the mixing / stirring area.
Chemical-resistant, impervious gloves complying with an approved standard must be worn at all times when handling chemical products. Reference number EN 374. Follow manufacturer specifications. Butyl rubber/nitrile rubber gloves (> 0,1 mm) Recommended: Butyl rubber/nitrile rubber gloves.
Safety glasses
In case of inadequate ventilation wear respiratory protection. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. organic vapor filter (Type A) A1: < 1000 ppm; A2: < 5000 ppm; A3: < 10000 ppm. In case this is not sufficient to keep the concentrations under the occupational exposure limits then respiration protection measures must be used.
Protective clothing (e.g. Safety shoes acc. to EN ISO 20345, long-sleeved working clothing, long trousers). Rubber aprons and protective boots are additionally recommended for mixing and stirring work. Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place.
No special environmental precautions required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable.
No dangerous reaction known under conditions of normal use.
No hazards to be specially mentioned.
No data available
No data available
No hazardous decomposition products are known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.1 Toxicity
12.5 Results of PBT and vPvB assessment
The substance/mixture does not contain PBT or vPvB components at levels of 0.1% or higher.
12.6 Endocrine disrupting properties
The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.
12.7 Other adverse effects
There is no data available for this product.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
In accordance with the EWC Waste Regulation the classification of waste is to be assigned to the jurisdiction of the origin of waste. Therefore, it is not possible to assign a particular waste identification number.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
All substances contained in our Products are registered by our upstream suppliers, and/or registered by us, and/or excluded from the regulation, and/or exempted from the registration.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Thomsit R 710 PART A?
The signal word is no signal word.
What is the physical form of Thomsit R 710 PART A?
Thomsit R 710 PART A is a liquid with grey color. It has characteristic odor.
What is Thomsit R 710 PART A used for?
Floor adhesive Product is not intended for consumer use For professional users only.