Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Naphthol As-bi N-acetyl-β-d-glucosaminide
- Product Code
- N4006
- Synonyms
- Naphthol AS-BI 2-acetamido-2-deoxy-β-D-glucopyranoside, 2-Naphthalenecarboxamide, 3-[[2-(acetylamino)-2-deoxy-β-D-glucopyranosyl]oxy]-7-bromo-N-(2-methoxyphenyl)-
Regulatory Identifiers
- CAS Number
- 3395-37-7 Check regulations →
Identified Uses
For R&D use only. Not for pharmaceutical, household or other uses.
Manufacturers & Suppliers
Merck Life Science Pty Ltd
national supplier
Ground Floor, Building 1, 885 Mountain Highway BAYSWATER VIC 3153 AUSTRALIA
+61 1800 800 097
Emergency Contacts
Emergency Contact
1800 862 115
24/7
CHEMTREC
+61 2 9037 2994
24/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
No components need to be disclosed according to the applicable regulations.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Naphthol AS-BI 2-acetamido-2-deoxy-β-D-glucopyranoside | 3395-37-7 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air.
Take off immediately all contaminated clothing. Rinse skin with water/ shower.
rinse out with plenty of water. Remove contact lenses.
make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides, Nitrogen oxides (NOx), Hydrogen bromide gas
Suppress (knock down) gases/vapors/mists with a water spray jet.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up dry. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Naphthol AS-BI β-D-glucuronide
CAS: 37-87-6
N-Acetyl-D-glucosamine
CAS: 7512-17-6
Naphthol AS-D acetate
CAS: 528-66-5
N-Methyl-D-glucamine
CAS: 6284-40-8
D-glucosyl-β-1,1' N-(9-(3-pent-4-ynyl-3-H-diazirin-3-yl)-nonanoyl)-D-erythro-sphingosine
---
2'-(4-Methylumbelliferyl)-α-D-N-acetylneuraminic acid sodium salt hydrate
---
D-glucosyl-β-1,1'-N-palmitoyl-D-erythro-sphingosine
---
N,N'-Diacetylbenzidine
CAS: 613-35-4
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed. Dry.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
No data available
No data available
no information available
No data available
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
12.6 Endocrine disrupting properties
12.7 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Waste material must be disposed of in accordance with the national and local regulations.
Leave chemicals in original containers. No mixing with other waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Therapeutic Goods (Poisons Standard) : No poison schedule number
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Naphthol As-bi N-acetyl-β-d-glucosaminide known by?
Naphthol As-bi N-acetyl-β-d-glucosaminide is also known as: Naphthol AS-BI 2-acetamido-2-deoxy-β-D-glucopyranoside, 2-Naphthalenecarboxamide, 3-[[2-(acetylamino)-2-deoxy-β-D-glucopyranosyl]oxy]-7-bromo-N-(2-methoxyphenyl)-
What is the hazard signal word for Naphthol As-bi N-acetyl-β-d-glucosaminide?
The signal word is no signal word.
What is the physical form of Naphthol As-bi N-acetyl-β-d-glucosaminide?
Naphthol As-bi N-acetyl-β-d-glucosaminide is a solid with no data available color. It has no data available odor.
What is Naphthol As-bi N-acetyl-β-d-glucosaminide used for?
For R&D use only. Not for pharmaceutical, household or other uses.
What is the melting point of Naphthol As-bi N-acetyl-β-d-glucosaminide?
The melting point is No data available and the boiling point is No data available.