Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ultragel II
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Non-Destructive Testing
Manufacturers & Suppliers
Magnaflux
manufacturer
155 Harlem Ave. Glenview, IL 60025 - USA
847-657-5300
Emergency Contacts
CHEMTREC
800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Glycerin | 56-81-5 | 11.47% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical advice/attention if you feel unwell.
Symptoms: May cause respiratory tract irritation.
If irritation occurs, flush skin with plenty of water. Get medical attention if irritation persists.
Symptoms: May cause skin irritation. Symptoms may include redness, drying, defatting and cracking of the skin.
In case of contact, immediately flush eyes with plenty of water. Remove contact lenses, if worn. If irritation persists, get medical attention.
Symptoms: May cause eye irritation. Symptoms may include discomfort or pain, excess blinking and tear production, with possible redness and swelling.
If swallowed, do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical advice/attention if you feel unwell.
Symptoms: May be harmful if swallowed. May cause stomach distress, nausea or vomiting.
Immediate Medical Attention
In case of accident or if you feel unwell, seek medical advice immediately (show the label or SDS where possible).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Treat for surrounding material.
None known.
Fire hazard: Products of combustion may include, and are not limited to: oxides of carbon.
Keep upwind of fire.
Firefighter Protection
Wear full fire fighting turn-out gear (full Bunker gear) and respiratory protection (SCBA).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel. Spills of this material are a slipping hazard.
Scoop up material and place in a disposal container.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Avoid breathing dust/fume/gas/mist/vapours/spray. Do not swallow. Handle and open container with care. When using do not eat, drink or smoke. Benzene may be present in trace amounts. Benzene is subject to the standard 29 CFR 1910.1028 which may contain specific requirements for handling including protective equipment, regulated areas, monitoring and medical surveillance. The employer should review the standard and assure compliance with applicable requirements.
Keep out of the reach of children. Keep container tightly closed. Keep away from heat and direct sunlight.
Launder contaminated clothing before reuse. Wash hands before eating, drinking, or smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use ventilation adequate to keep exposures (airborne levels of dust, fume, vapor, etc.) below recommended exposure limits.
Wear suitable gloves.
Safety glasses or goggles are recommended when using product.
In case of insufficient ventilation, wear suitable respiratory equipment. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.
Wear suitable protective clothing.
Maintain levels below Community environmental protection thresholds.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal storage conditions.
No dangerous reaction known under conditions of normal use.
No dangerous reaction known under conditions of normal use.
Heat. Incompatible materials.
Strong acids. Isocyanates. Strong oxidizers. Nitric acid. Chromium trioxide. Potassium chlorate. Potassium permanganate. Acetic anhydride. Chromium oxides. Alkali metals. metal hydrides. Peroxides.
May include, and are not limited to: oxides of carbon, hydrocarbons, nitrogen oxides, acrolein.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. TOXICITY
12.1. TOXICITY
May cause long-term adverse effects in the aquatic environment.
12.2. PERSISTENCE AND DEGRADABILITY
Not established.
12.3. BIOACCUMULATIVE POTENTIAL
Not established.
12.4. MOBILITY IN SOIL
No additional information available
12.5. OTHER ADVERSE EFFECTS
No known effects on global warming from this product.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
This material must be disposed of in accordance with all local, state, provincial, and federal regulations. The generation of waste should be avoided or minimized wherever possible.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Ultragel II?
The signal word is no signal word.
What is the physical form of Ultragel II?
Ultragel II is a liquid appearing as gel with blue color. It has mild detergent odor.
What is the solubility of Ultragel II?
No data available
What is Ultragel II used for?
Non-Destructive Testing
What is the melting point of Ultragel II?
The melting point is No data available and the boiling point is No data available.