Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Sika® Permacor®-2230 VHS Part B
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Corrosion protection
Uses advised against
Product is not intended for consumer use
Manufacturers & Suppliers
Sika Deutschland GmbH
manufacturer
Kornwestheimer Str. 103-107 D-70439 Stuttgart
+49 711 8009 0
Emergency Contacts
GBK GmbH Global Regulatory Compliance
+49(0)6132-84463
24-Hour-Number
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hexamethylene-1,6-diisocyanate homopolymer EC: 931-274-8 | 28182-81-2 | 60 - 80% | Yes |
| xylene EC: 215-535-7 | 1330-20-7 | 10 - 20% | Yes |
| 2-methoxy-1-methylethyl acetate EC: 203-603-9 | 108-65-6 | 10 - 20% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Consult a physician after significant exposure.
Symptoms: Harmful if inhaled. May cause respiratory irritation.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. If symptoms persist, call a physician.
Symptoms: Causes skin irritation. May cause an allergic skin reaction.
Immediately flush eye(s) with plenty of water. Remove contact lenses. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Symptoms: Causes serious eye irritation.
Do not induce vomiting without medical advice. Rinse mouth with water. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Alcohol-resistant foam, Carbon dioxide (CO2), Dry chemical
Water
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Remove all sources of ignition. Deny access to unprotected persons.
Prevent product from entering drains. If the product contaminates rivers and lakes or drains inform respective authorities.
collect with non-combustible absorbent material, and place in container for disposal according to local / national regulations (see section 13)
Materials: non-combustible absorbent material (e.g. sand, earth, diatomaceous earth, vermiculite)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid exceeding the given occupational exposure limits (see section 8). Do not get in eyes, on skin, or on clothing. For personal protection see section 8. Persons with a history of skin sensitisation problems or asthma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this mixture is being used. Smoking, eating and drinking should be prohibited in the application area. Take precautionary measures against static discharge. Open drum carefully as content may be under pressure. Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours).
Keep container tightly closed in a dry and well-ventilated place. Store in accordance with local regulations.
Handle in accordance with good industrial hygiene and safety practice. When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.
Keep away from heat/sparks/open flames/hot surfaces. No smoking. Take precautionary measures against electrostatic discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation. This can be achieved by local exhaust extraction or by general ventilation. (EN 689 - Methods for determining inhalation exposure). This applies in particular to the mixing / stirring area. In case this is not sufficient to keep the concentrations under the occupational exposure limits then respiration protection measures must be used. Ensure adequate ventilation, especially in confined areas.
Chemical-resistant, impervious gloves complying with an approved standard must be worn at all times when handling chemical products. Reference number EN 374. Follow manufacturer specifications. Suitable for short time use or protection against splashes: Butyl rubber/nitrile rubber gloves (0,4 mm) Contaminated gloves should be removed. Suitable for permanent exposure: Viton gloves (0.4 mm), breakthrough time >30 min.
Safety glasses with side-shields conforming to EN166 Eye wash bottle with pure water
Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. organic vapor (Type A) and particulate filter A1: < 1000 ppm; A2: < 5000 ppm; A3: < 10000 ppm P1: Inert material; P2, P3: hazardous substances. In case this is not sufficient to keep the concentrations under the occupational exposure limits then respiration protection measures must be used.
Protective clothing (e.g. Safety shoes acc. to EN ISO 20345, long-sleeved working clothing, long trousers). Rubber aprons and protective boots are additionally recommended for mixing and stirring work.
Prevent product from entering drains. If the product contaminates rivers and lakes or drains inform respective authorities.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable.
No dangerous reaction known under conditions of normal use.
Stable under recommended storage conditions. Vapours may form explosive mixture with air.
Heat, flames and sparks.
No data available
No decomposition if stored and applied as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
In accordance with the EWC Waste Regulation the classification of waste is to be assigned to the jurisdiction of the origin of waste.
It is not possible to assign a particular waste identification number.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1866
- Shipping Name
- RESIN SOLUTION
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
REACH Information: All substances contained in our Products are registered by our upstream suppliers, and/or registered by us, and/or excluded from the regulation, and/or exempted from the registration.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Sika® Permacor®-2230 VHS Part B?
The signal word is warning.
What is the physical form of Sika® Permacor®-2230 VHS Part B?
Sika® Permacor®-2230 VHS Part B is a liquid appearing as liquid with yellow color. It has slight odor.
What is Sika® Permacor®-2230 VHS Part B used for?
Corrosion protection
What are the hazard statements for Sika® Permacor®-2230 VHS Part B?
This substance has 7 hazard statements:
- H226: Flammable liquid and vapour.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H332: Harmful if inhaled.
- H335: May cause respiratory irritation.
- H373: May cause damage to organs (hearing organs) through prolonged or repeated exposure if inhaled.
What is the melting point of Sika® Permacor®-2230 VHS Part B?
The melting point is No data available and the boiling point is ca. 145 °C.