Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Dimethyl sulfoxide-d6
- Product Code
- 156914
- Chemical Name
- Dimethyl sulfoxide-d6
Regulatory Identifiers
- CAS Number
- 2206-27-1 Check regulations →
Identified Uses
Laboratory chemicals, Manufacture of substances
Manufacturers & Suppliers
Sigma-Aldrich
manufacturer
3050 Spruce Street, SAINT LOUIS MO 63103, USA
+1 800-325-5832
Emergency Contacts
Emergency Contact
(314) 776-6555
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| di[(2H3)Methyl] sulphoxide EC: 218-617-0 | 2206-27-1 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
Wash off with soap and plenty of water. Consult a physician.
Flush eyes with water as a precaution.
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid breathing vapours, mist or gas. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.
Prevent further leakage or spillage if safe to do so.
collect with an electrically protected vacuum cleaner or by wet-brushing and place in container for disposal according to local regulations (see section 13). Keep in suitable, closed containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid inhalation of vapour or mist. Keep away from sources of ignition - No smoking. Take measures to prevent the build up of electrostatic charge.
Keep container tightly closed in a dry and well-ventilated place.
Keep away from sources of ignition - No smoking. Take measures to prevent the build up of electrostatic charge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle in accordance with good industrial hygiene and safety practice.
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. Full contact Material: Chloroprene Minimum layer thickness: 0.6 mm Break through time: 480 min Material tested: Camapren® (KCL 722 / Aldrich Z677493, Size M) Splash contact Material: Nitrile rubber Minimum layer thickness: 0.2 mm Break through time: 30 min Material tested: Dermatril® P (KCL 743 / Aldrich Z677388, Size M) data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374 If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No data available
No data available
Heat, flames and sparks.
Acid chlorides, Phosphorus halides, Strong acids, Strong oxidizing agents, Strong reducing agents
Other decomposition products - No data available. In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.1 Toxicity
12.2 Persistence and degradability
No data available
12.3 Bioaccumulative potential
No data available
12.4 Mobility in soil
No data available
12.5 Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
This combustible material may be burned in a chemical incinerator equipped with an afterburner and scrubber.
Offer surplus and non-recyclable solutions to a licensed disposal company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1993
- Shipping Name
- Combustible liquid, n.o.s. (di[(2H3)Methyl] sulphoxide)
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Dimethyl sulfoxide-d6?
The signal word is warning.
What is the physical form of Dimethyl sulfoxide-d6?
Dimethyl sulfoxide-d6 is a liquid .
What is Dimethyl sulfoxide-d6 used for?
Laboratory chemicals, Manufacture of substances
What are the hazard statements for Dimethyl sulfoxide-d6?
This substance has 1 hazard statement:
- H227: Combustible liquid.
What is the melting point of Dimethyl sulfoxide-d6?
The melting point is 18.4 °C (65.1 °F) and the boiling point is 189 °C (372 °F) - lit..