Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Zeocin, 100 mg/ml in HEPES
- Product Code
- J67140
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals.
Uses advised against
Food, drug, pesticide or biocidal product use.
Manufacturers & Suppliers
Thermo Fisher Scientific Chemicals, Inc.
manufacturer
30 Bond Street, Ward Hill, MA 01835-8099
800-343-0660
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Contact
001-201-796-7100
Emergency Contact
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Water | 7732-18-5 | 98.76% | No |
| Phleomycin | 11006-33-0 | 1% | No |
| HEPES | 7365-45-9 | 0.24% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
No information available
None reasonably foreseeable.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment as required.
Should not be released into the environment.
Soak up with inert absorbent material. Keep in suitable, closed containers for disposal.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Ensure adequate ventilation. Do not get in eyes, on skin, or on clothing. Avoid ingestion and inhalation.
Store in freezer.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas.
Wear appropriate protective gloves
Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166.
Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Organic gases and vapours filter. Type A. Brown. conforming to EN14387.
Wear appropriate protective clothing to prevent skin exposure.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
None under normal processing.
Incompatible products.
Strong oxidizing agents
Carbon monoxide (CO), Carbon dioxide (CO₂), Nitrogen oxides (NOx), Sulfur oxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Ecotoxicity
Persistence and Degradability
Bioaccumulation/ Accumulation
Mobility
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste.
Chemical waste generators must also consult local, regional, and national hazardous waste regulations to ensure complete and accurate classification.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Zeocin, 100 mg/ml in HEPES?
The signal word is warning.
What is the physical form of Zeocin, 100 mg/ml in HEPES?
Zeocin, 100 mg/ml in HEPES is a liquid with colorless color. It has no information available odor.
What is Zeocin, 100 mg/ml in HEPES used for?
Laboratory chemicals.
What are the hazard statements for Zeocin, 100 mg/ml in HEPES?
This substance has 2 hazard statements:
- H317: May cause an allergic skin reaction
- H351: Suspected of causing cancer
What is the melting point of Zeocin, 100 mg/ml in HEPES?
The melting point is No data available and the boiling point is No information available.