Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- UNICOOL R-407C
- Product Code
- 905624, 905607, 905752, 905753, 905807, 905824
- Synonyms
- 905624; 905607
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- DE2W-VK77-K206-7ET9
Identified Uses
The use of a quantity of material in an unventilated or confined space may result in increased exposure and an irritating atmosphere developing. Before starting consider control of exposure by mechanical ventilation.
Uses advised against
No specific uses advised against are identified.
Manufacturers & Suppliers
Wilhelmsen Ships Service AS
manufacturer
Strandveien 20 Lysaker 1366 Norway
+47 67 58 40 00
https://www.wilhelmsen.com/
Wilhelmsen Ships Service AS Central Warehouse
manufacturer
Willem Barentszstraat 50 Rotterdam 3165AB Netherlands
+31 10 4877 777
https://www.wilhelmsen.com/
Emergency Contacts
Norwegian Environment Agency
4722591300
Norwegian Institute of Public Health, NIPH (Norwegian Poison Information Centre)
47 21 07 70 00
Giftinformasjonsentralen - 24 timer
+47 22 59 13 00
24 timer
Emergency Contact
+31-10-4877700
Dutch nat. poison centre
+ 31 88 7558561
24hrs - Chemwatch
+31-10-4877700
Emergency Contact
+ 31 10 4877700
CHEMWATCH EMERGENCY RESPONSE (24/7)
+47 23 25 25 84
24/7
Emergency Contact
+61 3 9573 3188
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Following exposure to gas, remove the patient from the gas source or contaminated area. Prostheses such as false teeth, which may block the airway, should be removed, where possible, prior to initiating first aid procedures. If the patient is not breathing spontaneously, administer rescue breathing. If the patient does not have a pulse, administer CPR. If medical oxygen and appropriately trained personnel are available, administer 100% oxygen. Summon an emergency ambulance. If an ambulance is not available, contact a physician, hospital, or Poison Control Centre for further instruction. Keep the patient warm, comfortable and at rest while awaiting medical care. MONITOR THE BREATHING AND PULSE, CONTINUOUSLY. Administer rescue breathing (preferably with a demand-valve resuscitator, bag-valve mask-device, or pocket mask as trained) or CPR if necessary.
Immediately remove all contaminated clothing, including footwear. Flush skin and hair with running water (and soap if available). Seek medical attention in event of irritation. In case of cold burns (frost-bite): Move casualty into warmth before thawing the affected part; if feet are affected carry if possible Bathe the affected area immediately in luke-warm water (not more than 35 deg C) for 10 to 15 minutes, immersing if possible and without rubbing Apply a clean, dry, light dressing of "fluffed-up" dry gauze bandage If a limb is involved, raise and support this to reduce swelling If an adult is involved and where intense pain occurs provide pain killers such as paracetomol Transport to hospital, or doctor Subsequent blackening of the exposed tissue indicates potential of necrosis, which may require amputation. DO NOT apply hot water or radiant heat.
If product comes in contact with eyes remove the patient from gas source or contaminated area. Take the patient to the nearest eye wash, shower or other source of clean water. Open the eyelid(s) wide to allow the material to evaporate. Gently rinse the affected eye(s) with clean, cool water for at least 15 minutes. Have the patient lie or sit down and tilt the head back. Hold the eyelid(s) open and pour water slowly over the eyeball(s) at the inner corners, letting the water run out of the outer corners. The patient may be in great pain and wish to keep the eyes closed. It is important that the material is rinsed from the eyes to prevent further damage. Ensure that the patient looks up, and side to side as the eye is rinsed in order to better reach all parts of the eye(s) Transport to hospital or doctor. Even when no pain persists and vision is good, a doctor should examine the eye as delayed damage may occur. If the patient cannot tolerate light, protect the eyes with a clean, loosely tied bandage. Ensure verbal communication and physical contact with the patient. DO NOT allow the patient to rub the eyes DO NOT allow the patient to tightly shut the eyes DO NOT introduce oil or ointment into the eye(s) without medical advice DO NOT use hot or tepid water.
Avoid giving milk or oils. Avoid giving alcohol. For advice, contact a Poisons Information Centre or a doctor. If spontaneous vomiting appears imminent or occurs, hold patient's head down, lower than their hips to help avoid possible aspiration of vomitus.
Symptoms: Not considered a normal route of entry.
Immediate Medical Attention
Summon an emergency ambulance.
Medical Treatment
Maintain an open airway and assist ventilation if necessary. Treat coma and arrhythmias if they occur. Tachyarrhythmias caused by increased myocardial sensitisation may be treated with propranolol, 1-2 mg IV or esmolol 25-100 microgm/kg/min IV. Because rapid absorption may occur through lungs if aspirated and cause systematic effects, the decision of whether to induce vomiting or not should be made by an attending physician. If lavage is performed, suggest endotracheal and/or esophageal control. Danger from lung aspiration must be weighed against toxicity when considering emptying the stomach. Treatment based on judgment of the physician in response to reactions of the patient. Analgesia may be necessary while thawing. Shock may occur during rewarming. Administer tetanus toxoid booster after hospitalization. Prophylactic antibiotics may be useful. The patient may require anticoagulants and oxygen. Establish a patent airway with suction where necessary. Watch for signs of respiratory insufficiency and assist ventilation as necessary. Administer oxygen by non-rebreather mask at 10 to 15 l/min. Monitor and treat, where necessary, for pulmonary oedema. Monitor and treat, where necessary, for shock. Anticipate seizures. Consider orotracheal or nasotracheal intubation for airway control in unconscious patient or where respiratory arrest has occurred. Positive-pressure ventilation using a bag-valve mask might be of use. Monitor and treat, where necessary, for arrhythmias. Start an IV D5W TKO. If signs of hypovolaemia are present use lactated Ringers solution. Fluid overload might create complications. Drug therapy should be considered for pulmonary oedema. Hypotension with signs of hypovolaemia requires the cautious administration of fluids. Fluid overload might create complications. Treat seizures with diazepam.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing agent suitable for type of surrounding fire.
DO NOT direct water at source of leak or venting safety devices as icing may occur.
Fire Incompatibility: Avoid contamination with oxidising agents i.e. nitrates, oxidising acids, chlorine bleaches, pool chlorine etc. as ignition may result
LARGE FIRE: Cool cylinder.
Firefighter Protection
Wear breathing apparatus and protective gloves.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Minor Spills: Avoid breathing vapour and any contact with liquid or gas. DO NOT enter confined spaces where gas may have accumulated. Major Spills: Clear area of all unprotected personnel and move upwind. Alert Emergency Authority and advise them of the location and nature of hazard. Remove leaking cylinders to a safe place. Fit vent pipes. Release pressure under safe, controlled conditions. Burn issuing gas at vent pipes. DO NOT exert excessive pressure on valve; DO NOT attempt to operate damaged valve.
Avoid breathing vapour and any contact with liquid or gas. Protective equipment including respirator should be used. DO NOT enter confined spaces where gas may have accumulated.
Clear area of all unprotected personnel and move upwind. Alert Emergency Authority and advise them of the location and nature of hazard. Wear breathing apparatus and protective gloves. Remove leaking cylinders to a safe place. Fit vent pipes. Release pressure under safe, controlled conditions. Burn issuing gas at vent pipes. DO NOT exert excessive pressure on valve; DO NOT attempt to operate damaged valve.
See section 12
Release pressure under safe, controlled conditions. Burn issuing gas at vent pipes.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Consider use in closed pressurised systems, fitted with temperature, pressure and safety relief valves which are vented for safe dispersal. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. The tubing network design connecting gas cylinders to the delivery system should include appropriate pressure indicators and vacuum or suction lines. Fully-welded types of pressure gauges, where the bourdon tube sensing element is welded to the gauge body, are recommended. DO NOT transfer gas from one cylinder to another.
Cylinders should be stored in a purpose-built compound with good ventilation, preferably in the open. Such compounds should be sited and built in accordance with statutory requirements. The storage compound should be kept clear and access restricted to authorised personnel only.
See section 5
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Well-designed engineering controls can be highly effective in protecting workers and will typically be independent of worker interactions to provide this high level of protection. The basic types of engineering controls are: Process controls which involve changing the way a job activity or process is done to reduce the risk.
• Butyl rubber gloves • Butyl rubber gloves should be used when handling halogenated aliphatics. • Nitrile, PVC-coated nitrile, and PVC protective equipment are not recommended • When handling sealed and suitably insulated cylinders wear cloth or leather gloves. • Insulated gloves: NOTE: Insulated gloves should be loose fitting so that may be removed quickly if liquid is spilled upon them. Insulated gloves are not made to permit hands to be placed in the liquid; they provide only short-term protection from accidental contact with the liquid.
• Chemical goggles. • Full face shield may be required for supplementary but never for primary protection of eyes. • Contact lenses may pose a special hazard; soft contact lenses may absorb and concentrate irritants.
Type AX Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent). Selection of the Class and Type of respirator will depend upon the level of breathing zone contaminant and the chemical nature of the contaminant. Protection Factors (defined as the ratio of contaminant outside and inside the mask) may also be important. Cartridge respirators should never be used for emergency ingress or in areas of unknown vapour concentrations or oxygen content. The wearer must be warned to leave the contaminated area immediately on detecting any odours through the respirator. Cartridge performance is affected by humidity. Cartridges should be changed after 2 hr of continuous use unless it is determined that the humidity is less than 75%, in which case, cartridges can be used for 4 hr. Used cartridges should be discarded daily, regardless of the length of time used. Positive pressure, full face, air-supplied breathing apparatus should be used for work in enclosed spaces if a leak is suspected or the primary containment is to be opened (e.g. for a cylinder change). Air-supplied breathing apparatus is required where release of gas from primary containment is either suspected or demonstrated.
Protective overalls, closely fitted at neck and wrist.
See section 12
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Product is considered stable. Unstable in the presence of incompatible materials.
See section 7.2
Hazardous polymerisation will not occur.
See section 7.2
See section 7.2
See section 5.3
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.2. Persistence and degradability
12.2. Persistence and degradability
12.1. Toxicity
No toxicity data available.
12.1. Toxicity
12.1. Toxicity
12.1. Toxicity
12.2. Persistence and degradability
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.4. Mobility in soil
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
UNICOOL R-407C does not fulfill the PBT or vPvB criteria.
12.5. Results of PBT and vPvB assessment
Pentafluoroethane does not fulfill the PBT or vPvB criteria.
12.5. Results of PBT and vPvB assessment
The substance 1,1,1,2-tetrafluoroethane does not fulfill the PBT or vPvB criteria.
12.6. Endocrine disrupting properties
No evidence of endocrine disrupting properties were found in the current literature.
12.7. Other adverse effects
No evidence of ozone depleting properties were found in the current literature.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Not Available
Evaporate residue at an approved site.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3340
- Shipping Name
- REFRIGERANT GAS R 407C (Difluoromethane, pentafluoroethane, and 1,1,1,2-tetrafluoroethane zeotropic mixture with approximately 23%difluoromethane and 25% pentafluoroethane)
- Transport Class
- 2.2
- Packing Group
- Not Applicable
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This safety data sheet is in compliance with the following EU legislation and its adaptations - as far as applicable - : Directives 98/24/EC, - 92/85/EEC, - 94/33/EC, - 2008/98/EC, - 2010/75/EU; Commission Regulation (EU) 2020/878; Regulation (EC) No 1272/2008 as updated through ATPs.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is UNICOOL R-407C known by?
UNICOOL R-407C is also known as: 905624; 905607
What is the hazard signal word for UNICOOL R-407C?
The signal word is warning.
What is the physical form of UNICOOL R-407C?
UNICOOL R-407C is a liquified gas appearing as liquefied pressure gas with sweet ether-like odour; insoluble in water. . It has not available odor.
What is UNICOOL R-407C used for?
The use of a quantity of material in an unventilated or confined space may result in increased exposure and an irritating atmosphere developing. Before starting consider control of exposure by mechanical ventilation.
What are the hazard statements for UNICOOL R-407C?
This substance has 2 hazard statements:
- H280: Contains gas under pressure; may explode if heated.
- H315: Causes skin irritation.
What is the melting point of UNICOOL R-407C?
The melting point is <-100-760 °C and the boiling point is -44.8-760 °C.