NextSDS Logo
R-

R-407C

WARNING Gas SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
R-407C
Product Code
WAG-G1149

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial and professional uses. Perform risk assessment prior to use. Use as refrigerant. Test gas/Calibration gas. Laboratory use.
Uses Advised Against
Consumer use. Uses other than those listed above are not supported, contact your supplier for more information on other uses.

Overview

R-407C commonly used industrial and professional uses. perform risk assessment prior to use. use as refrigerant. test gas/calibration gas. laboratory use..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Press. Gas H280

GHS Hazard Pictograms & Safety Symbols

GHS04 GHS Hazard Pictogram: Compressed gas hazard - Pressurized gases that may explode if heated

GHS04

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H280: Contains gas under pressure; may explode if heated.

Precautionary Statements

  • P403: Store in a well-ventilated place.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Westfalen BV-SRL company logo - Safety Data Sheet supplier organization

Westfalen BV-SRL

national supplier

๐Ÿ“

Watermolenstraat 11, 11 BE 9320 Aalst/Alost Belgi - Belgique

๐ŸŒ

BE

๐ŸŒ www.westfalen.be

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+32 53 641070

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Tetrafluoroethane (R134a)
EC: 212-377-0
811-97-2 52% โš ๏ธ Hazardous
Pentafluoroethane
EC: 206-557-8
354-33-6 25% โš ๏ธ Hazardous
Difluoromethane (R32)
EC: 200-839-4
75-10-5 23% โš ๏ธ Hazardous

Composition Notes

Contains no other components or impurities which will influence the classification of the product.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.

Symptoms:

In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.

๐Ÿšจ Immediate Medical Attention Required

None.

Medical Treatment

None.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Gas
Critical Property
๐Ÿ“Š Physical State Data
gas
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Mixture contains one or more component(s) which have the following colour(s): Colourless.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
There may be no odour warning properties, odour is subjective and inadequate to warn of overexposure. Mixture contains one or more component(s) which have the following odour: Ethereal.
๐Ÿ“Š Odor Threshold
Odour threshold is subjective and inadequate to warn of overexposure.
๐Ÿงช Ph
Not applicable for gases and gas mixtures.
๐ŸงŠ Melting Point
Not applicable for gases and gas mixtures.
Critical Property
๐Ÿ’จ Boiling Point
Not applicable for gas mixtures.
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable for gases and gas mixtures.
Critical Property
๐Ÿ“Š Freezing Point
Not applicable for gases and gas mixtures.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not applicable.
๐Ÿ“Š Vapor Density
Not applicable for gases and gas mixtures.
๐Ÿ“Š Relative Density
Not applicable
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not applicable
Critical Property
๐Ÿ”ฅ Flammability
Non flammable.
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Non flammable.
๐Ÿ“Š Decomposition Temperature
Not applicable.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not applicable for gas mixtures.
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not applicable for gases and gas mixtures.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide adequate general and local exhaust ventilation. Oxygen detectors should be used when asphyxiating gases may be released. Systems under pressure should be regularily checked for leakages. Ensure exposure is below occupational exposure limits (where available). Consider the use of a work permit system e.g. for maintenance activities.

๐Ÿงค Hand Protection

Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risk, performance level 1 or higher.

๐Ÿ‘๏ธ Eye Protection

Wear safety glasses with side shields. Standard EN 166 - Personal eye-protection - specifications.

๐Ÿ˜ท Respiratory Protection

Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. When indicated by a risk assessment, Respiratory Protective Equipment must be used. The selection of the Respiratory Protective Device (RPD) must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected RPD.

๐Ÿฆบ Skin/Body Protection

Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.

๐ŸŒ Environmental Exposure Controls

Refer to local regulations for restriction of emissions to the atmosphere. See section 13 for specific methods for waste gas treatment.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3340

๐Ÿ“ฆ Proper Shipping Name

REFRIGERANT GAS R 407C

โš ๏ธ Transport Hazard Class

2.2

๐Ÿ“‹ Packing Group

Not applicable

๐Ÿš› ADR Transport Precautions

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

๐Ÿšข IMDG Maritime Transport Precautions

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

โœˆ๏ธ IATA Air Transport Precautions

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for R-407C?

The signal word for this substance is "warning".

What is the physical form of R-407C?

R-407C is a gas with mixture contains one or more component(s) which have the following colour(s): colourless. color. It has there may be no odour warning properties, odour is subjective and inadequate to warn of overexposure. mixture contains one or more component(s) which have the following odour: ethereal. odor.

What is R-407C used for?

Industrial and professional uses. Perform risk assessment prior to use. Use as refrigerant. Test gas/Calibration gas. Laboratory use.

What are the hazard statements for R-407C?

This substance has 1 hazard statements: H280: Contains gas under pressure; may explode if heated.

What is the melting point of R-407C?

The melting point is Not applicable for gases and gas mixtures. and the boiling point is Not applicable for gas mixtures..