NextSDS Logo
Safety Data Sheet EN

R-407C

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
R-407C
Product Code
WAG-G1149

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial and professional uses. Perform risk assessment prior to use. Use as refrigerant. Test gas/Calibration gas. Laboratory use.

Uses advised against

Consumer use. Uses other than those listed above are not supported, contact your supplier for more information on other uses.

Manufacturers & Suppliers

Westfalen BV-SRL logo

Westfalen BV-SRL

national supplier

Watermolenstraat 11, 11 BE 9320 Aalst/Alost Belgi - Belgique

www.westfalen.be

Emergency Contacts

Emergency Contact

+32 53 641070

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Gases under pressure : Compressed gas H280

GHS Pictograms

GHS04 - Compressed gas

GHS04

Hazard Statements

H280 Contains gas under pressure; may explode if heated.

Precautionary Statements

P403 Store in a well-ventilated place.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Tetrafluoroethan (R134a) EC: 212-377-0 811-97-2 52% Yes
Pentafluorethan EC: 206-557-8 354-33-6 25% Yes
Difluoromethane (R32) EC: 200-839-4 75-10-5 23% Yes

Notes

Contains no other components or impurities which will influence the classification of the product.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.

Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.

Immediate Medical Attention

None.

Medical Treatment

None.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate general and local exhaust ventilation. Oxygen detectors should be used when asphyxiating gases may be released. Systems under pressure should be regularily checked for leakages. Ensure exposure is below occupational exposure limits (where available). Consider the use of a work permit system e.g. for maintenance activities.

Hands

Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risk, performance level 1 or higher.

Eyes

Wear safety glasses with side shields. Standard EN 166 - Personal eye-protection - specifications.

Respiratory

Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. When indicated by a risk assessment, Respiratory Protective Equipment must be used. The selection of the Respiratory Protective Device (RPD) must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected RPD.

Skin/Body

Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.

Environmental

Refer to local regulations for restriction of emissions to the atmosphere. See section 13 for specific methods for waste gas treatment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Boiling Point
Not applicable for gas mixtures.
Vapor Density
Not applicable for gases and gas mixtures.
Auto Ignition Temperature
Non flammable.
Solubility In Fat
---
Cloud Point
---
Softening Point
---
Upper Explosive Limit
Not available
Solubility In Water
Not available
Form
---
Relative Evaporation Rate
---
Lower Explosive Limit
Not available
Properties Status
---
Flammability
Non flammable.
Physical State
Gas
Crystallisation Point
---
Molecular Weight
---
Dynamic Viscosity
---
Melting Point
Not applicable for gases and gas mixtures.
Appearance
---
Freezing Point
Not applicable for gases and gas mixtures.
Solubility
---
Density
Not applicable
Colour
Mixture contains one or more component(s) which have the following colour(s): Colourless.
Explosive Limits
---
Flash Point
Not applicable for gases and gas mixtures.
State Under Standard Conditions
---
Evaporation Rate
---
Partition Coefficient
Not applicable for gas mixtures.
Vapor Pressure
Not applicable.
Odor Threshold
Odour threshold is subjective and inadequate to warn of overexposure.
Decomposition Temperature
Not applicable.
Voc Content
---
Odor
There may be no odour warning properties, odour is subjective and inadequate to warn of overexposure. Mixture contains one or more component(s) which have the following odour: Ethereal.
Relative Density
Not applicable
Colour Intensity
---
Metal Corrosion
---
Solidification Point
---
Ph
Not applicable for gases and gas mixtures.
Bulk Density
---
Kinematic Viscosity
Not applicable for gases and gas mixtures.
Physical State Data
gas
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3340
Shipping Name
REFRIGERANT GAS R 407C
Transport Class
2.2
Packing Group
Not applicable
ADR

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

IMDG

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

IATA

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for R-407C?

The signal word is warning.

What is the physical form of R-407C?

R-407C is a gas with mixture contains one or more component(s) which have the following colour(s): colourless. color. It has there may be no odour warning properties, odour is subjective and inadequate to warn of overexposure. mixture contains one or more component(s) which have the following odour: ethereal. odor.

What is R-407C used for?

Industrial and professional uses. Perform risk assessment prior to use. Use as refrigerant. Test gas/Calibration gas. Laboratory use.

What are the hazard statements for R-407C?

This substance has 1 hazard statement:

  • H280: Contains gas under pressure; may explode if heated.

What is the melting point of R-407C?

The melting point is Not applicable for gases and gas mixtures. and the boiling point is Not applicable for gas mixtures..

Compliance Scan