NextSDS Logo
Safety Data Sheet EN

ALENTRA CLEANER

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ALENTRA CLEANER
Chemical Name
Cleaner

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Cleaning of closed water circuits Detergent Chemical industry - Metallurgy.

Manufacturers & Suppliers

I

I.D.A. Bvba

manufacturer

Turnhoutseweg 2, 2440 GEEL, BELGIUM

+32 476 55 19 50

Emergency Contacts

www.poisoncentre.be

070 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Carbonic acid sodium salt (1:2) Water & other 497-19-8 98% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If symptoms persist, call a physician.

Symptoms: At high concentrations: Cough. May cause nose, throat, and lung irritation. Risk of sore throat, nose bleeds.

Skin contact

Wash off with soap and water. If symptoms persist, call a physician.

Symptoms: Prolonged skin contact may cause skin irritation.

Eye contact

In case of eye contact, remove contact lens and rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. If eye irritation persists, consult a specialist.

Symptoms: Redness. Lachrymation. Swelling of tissue. Severe eye irritation.

Ingestion

Rinse mouth with water. Do NOT induce vomiting. If symptoms persist, call a physician or Poison Control Center immediately.

Symptoms: Severe irritation. Nausea. Abdominal pain. Vomiting. Diarrhea.

Immediate Medical Attention

If symptoms persist, call a physician or Poison Control Center immediately.

Medical Treatment

None.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

None.

Specific hazards

Not combustible.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus. Use personal protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate personnel to safe areas. Prevent further leakage or spillage.

Environmental

Prevent further leakage or spillage.

Cleanup methods

Sweep up to prevent slipping hazard.

Materials: properly labeled containers

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes.

Storage

Store in original container. Keep in a dry place. Keep in properly labeled containers. Keep container closed.

Hygiene

When using do not eat, drink or smoke. Wash hands before breaks and at the end of workday. Handle in accordance with good industrial hygiene and safety practice.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide appropriate exhaust ventilation. Apply technical measures to comply with the occupational exposure limits.

Hands

Wear suitable gloves. Suitable material: Neoprene, Natural Rubber

Eyes

Safety goggles

Respiratory

Effective mask, Use NIOSH approved respiratory protection. Use only respiratory protection that conforms to international/ national standards.

Skin/Body

Dust impervious protective suit, Rubber or plastic boots, Rubber or plastic apron

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
---
Physical State Data
---
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
106 g/mol
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

Decomposes by reaction with strong acids.

Hazardous reactions

no data available

Avoid

Exposure to moisture.

Incompatible

Finely divided aluminum

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Aquatic Compartment Acute toxicity to fish LC50 - 96 h : 300 mg/l - Lepomis macrochirus (Bluegill sunfish) static test Analytical monitoring: no Method: according to a standardized method Not harmful to fish (LC50 > 100 mg/L) Published data Acute toxicity to daphnia and other aquatic invertebrates. EC50 - 48 h : 200 - 227 mg/l - Ceriodaphnia dubia (water flea) semi-static test Method: according to a standardized method Not harmful to aquatic invertebrates. (EC50 > 100 mg/L) Published data

The substance is not considered harmful to fish (LC50 > 100 mg/L) or aquatic invertebrates (EC50 > 100 mg/L) based on published data.

12.2 Persistence and degradability

12.2 Persistence and degradability

12.2 Persistence and degradability

Abiotic degradation Photodegradation hydrolyzes Test substance: Water carbonic acid/bicarbonate/carbonate acid/base

12.2 Persistence and degradability

equilibrium as a function of pH Biodegradation Biodegradability Not applicable, inorganic substance

12.2 Persistence and degradability

ALENTRA CLEANER Revision Date 05/19/2015 Degradability assessment The product is not considered to be rapidly degradable in the environment

The product is not considered to be rapidly degradable in the environment.

12.3 Bioaccumulative potential

12.3 Bioaccumulative potential

Bioconcentration factor (BCF) Not applicable, inorganic substance

12.4 Mobility in soil

Adsorption potential (Koc) Air Not applicable Solubility(ies) Water Mobility Water Soil/sediments not significant

12.5 Results of PBT and vPvB assessment

Not applicable, inorganic substance

The substance is inorganic, therefore PBT and vPvB assessment is not applicable.

12.1 Toxicity

Ecotoxicity assessment Acute aquatic toxicity Not harmful to aquatic life (LC/EC50 > 100 mg/L) Chronic aquatic toxicity Not classified due to data which are conclusive although insufficient for classification.

12.6 Other adverse effects

no data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Contact waste disposal services. If recycling is not practicable, dispose of in compliance with local regulations. Dilute with plenty of water. Neutralize with acid. In accordance with local and national regulations.

Disposal

Contact waste disposal services. If recycling is not practicable, dispose of in compliance with local regulations. Dilute with plenty of water. Neutralize with acid.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This product has been classified according to the hazard criteria of the CPR and the MSDS contains all of the information required by the CPR.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ALENTRA CLEANER?

The signal word is no signal word.

What is ALENTRA CLEANER used for?

Cleaning of closed water circuits Detergent Chemical industry - Metallurgy.