Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ALENTRA CLEANER
- Chemical Name
- Cleaner
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cleaning of closed water circuits Detergent Chemical industry - Metallurgy.
Manufacturers & Suppliers
I.D.A. Bvba
manufacturer
Turnhoutseweg 2, 2440 GEEL, BELGIUM
+32 476 55 19 50
Emergency Contacts
www.poisoncentre.be
070 245 245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Carbonic acid sodium salt (1:2) Water & other | 497-19-8 | 98% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If symptoms persist, call a physician.
Symptoms: At high concentrations: Cough. May cause nose, throat, and lung irritation. Risk of sore throat, nose bleeds.
Wash off with soap and water. If symptoms persist, call a physician.
Symptoms: Prolonged skin contact may cause skin irritation.
In case of eye contact, remove contact lens and rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. If eye irritation persists, consult a specialist.
Symptoms: Redness. Lachrymation. Swelling of tissue. Severe eye irritation.
Rinse mouth with water. Do NOT induce vomiting. If symptoms persist, call a physician or Poison Control Center immediately.
Symptoms: Severe irritation. Nausea. Abdominal pain. Vomiting. Diarrhea.
Immediate Medical Attention
If symptoms persist, call a physician or Poison Control Center immediately.
Medical Treatment
None.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
None.
Not combustible.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus. Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate personnel to safe areas. Prevent further leakage or spillage.
Prevent further leakage or spillage.
Sweep up to prevent slipping hazard.
Materials: properly labeled containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes.
Store in original container. Keep in a dry place. Keep in properly labeled containers. Keep container closed.
When using do not eat, drink or smoke. Wash hands before breaks and at the end of workday. Handle in accordance with good industrial hygiene and safety practice.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide appropriate exhaust ventilation. Apply technical measures to comply with the occupational exposure limits.
Wear suitable gloves. Suitable material: Neoprene, Natural Rubber
Safety goggles
Effective mask, Use NIOSH approved respiratory protection. Use only respiratory protection that conforms to international/ national standards.
Dust impervious protective suit, Rubber or plastic boots, Rubber or plastic apron
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Decomposes by reaction with strong acids.
no data available
Exposure to moisture.
Finely divided aluminum
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
The substance is not considered harmful to fish (LC50 > 100 mg/L) or aquatic invertebrates (EC50 > 100 mg/L) based on published data.
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
12.2 Persistence and degradability
The product is not considered to be rapidly degradable in the environment.
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance is inorganic, therefore PBT and vPvB assessment is not applicable.
12.1 Toxicity
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Contact waste disposal services. If recycling is not practicable, dispose of in compliance with local regulations. Dilute with plenty of water. Neutralize with acid. In accordance with local and national regulations.
Contact waste disposal services. If recycling is not practicable, dispose of in compliance with local regulations. Dilute with plenty of water. Neutralize with acid.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product has been classified according to the hazard criteria of the CPR and the MSDS contains all of the information required by the CPR.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ALENTRA CLEANER?
The signal word is no signal word.