NextSDS Logo
Safety Data Sheet EN

Silica, monodisperse, non-porous, 10 µm

CAS 7631-86-9

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Silica, monodisperse, non-porous, 10 µm
Product Code
904368
Chemical Name
Silica

Regulatory Identifiers

CAS Number
7631-86-9 Check regulations →

Identified Uses

Laboratory chemicals, Synthesis of substances

Uses advised against

The product is being supplied under the TSCA R&D Exemption (40 CFR Section 720.36). It is the recipient's responsibility to comply with the requirements of the R&D exemption. The product may not be used for a non-exempt commercial purpose under TSCA unless appropriate consent is granted in writing by MilliporeSigma.

Manufacturers & Suppliers

S

Sigma-Aldrich Inc.

manufacturer

3050 SPRUCE ST, ST. LOUIS MO 63103, UNITED STATES

+1 314 771-5765

Emergency Contacts

CHEMTREC

800-424-9300

24 Hours/day; 7 Days/week

CHEMTREC

+1-703-527-3887

24 Hours/day; 7 Days/week

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

Not a hazardous substance or mixture according to the Globally Harmonized System (GHS).

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
silicon dioxide 7631-86-9 90 - 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

rinse out with plenty of water. Remove contact lenses.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Advice for non-emergency personnel: Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert. Advice for emergency responders: For personal protection see section 8.

Environmental

No special precautionary measures necessary.

Cleanup methods

Take up dry. Clean up affected area.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No data available

Hands

Material: Nitrile rubber, Break through time: 480 min, Glove thickness: 0.11 mm, Protective index: Full contact / Splash contact, Manufacturer: KCL 741 Dermatril® L

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P1

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
powder
Physical State Data
solid
State Under Standard Conditions
---
Appearance
powder
Colour
white
Colour Intensity
---
Form
---
Odor
odorless
Odor Threshold
Not applicable
Ph
3.7 - 4.7 (77 °F / 25 °C)
Melting Point
3,115 °F / 1,713 °C (ECHA)
Boiling Point
4,046 °F / 2,230 °C
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
2.56 g/cm3
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
not combustible
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
Not applicable for inorganic substances
Solubility In Water
ca. 0.076 g/l slightly soluble (99 °F / 37 °C) Method: OECD Test Guideline 105
Solubility In Fat
---
Molecular Weight
60.08 g/mol
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature) .

Reactivity

No data available

Hazardous reactions

Exothermic reaction with: Hydrogen halides, halogen oxides, alkali hydroxides, sodium, xenon hexafluoride

Avoid

no information available

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Ecotoxicity

Components: silicon dioxide: Toxicity to fish | : LC50 (Pimephales promelas (fathead minnow)): > 5,000 mg/l End point: mortality Exposure time: 96 h Test Type: static test Method: OECD Test Guideline 203 Toxicity to daphnia and : EC50 (Daphnia magna (Water flea)): > 5,000 mg/l other aquatic | Test Type: static test invertebrates | Method: OECD Test Guideline 202 Toxicity to algae/aquatic : ErC50 (Desmodesmus subspicatus (green algae)): > 173.1 mg/l plants | Test Type: static test Analytical monitoring: yes Method: OECD Test Guideline 201 GLP: yes Toxicity to daphnia and : NOEC (Daphnia magna (Water flea)): 68 mg/l other aquatic | End point: mortality invertebrates (Chronic | Test Type: semi-static test toxicity) | Analytical monitoring: yes Method: OECD Test Guideline 211 GLP: yes Toxicity to | : EC50 (activated sludge): > 1,000 mg/l microorganisms | Exposure time: 3 h Test Type: static test Method: OECD Test Guideline 209 GLP: yes

Persistence and degradability

Components: silicon dioxide: Biodegradability | : Remarks: The methods for determining biodegradability are not applicable to inorganic substances.

Bioaccumulative potential

Components: silicon dioxide: Partition coefficient: n- | : Remarks: Not applicable for inorganic substances

Mobility in soil

No data available

Other adverse effects

Components: silicon dioxide: Additional ecological | : No ecological problems are to be expected when the information | product is handled and used with due care and attention.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Waste material must be disposed of in accordance with the national and local regulations.

Disposal

Leave chemicals in original containers. No mixing with other waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Silica, monodisperse, non-porous, 10 µm?

The signal word is no signal word.

What is the physical form of Silica, monodisperse, non-porous, 10 µm?

Silica, monodisperse, non-porous, 10 µm is a powder appearing as powder with white color. It has odorless odor.

What is Silica, monodisperse, non-porous, 10 µm used for?

Laboratory chemicals, Synthesis of substances

What are the hazard statements for Silica, monodisperse, non-porous, 10 µm?

This substance has 1 hazard statement:

  • Not a hazardous substance or mixture according to the Globally Harmonized System (GHS).

What is the melting point of Silica, monodisperse, non-porous, 10 µm?

The melting point is 3,115 °F / 1,713 °C (ECHA) and the boiling point is 4,046 °F / 2,230 °C.