NextSDS Logo
73

7300 CombiColor Spuitbussen

DANGER Liquide. [Aérosol.] SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
7300 CombiColor Spuitbussen
Product Form
Aérosol.

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
NND0-J00D-F004-2FRA

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Utilisation par les consommateurs, Usage industriel, Utilisation professionnelle
Uses Advised Against
Non identifié.

Overview

7300 CombiColor Spuitbussen commonly used utilisation par les consommateurs, usage industriel, utilisation professionnelle.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
STOT SE Category 3 H336
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Aérosol extrêmement inflammable.
  • H229: Récipient sous pression: peut éclater sous l'effet de la chaleur.
  • H336: Peut provoquer somnolence ou vertiges.
  • H412: Nocif pour les organismes aquatiques, entraîne des effets néfastes à long terme.

Precautionary Statements

  • P101: En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
  • P102: Tenir hors de portée des enfants.
  • P103: Lire attentivement et bien respecter toutes les instructions.
  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P211: Ne pas vaporiser sur une flamme nue ou sur toute autre source d'ignition.
  • P251: Ne pas perforer, ni brûler, même après usage.
  • P271: Utiliser seulement en plein air ou dans un endroit bien ventilé.
  • P410+P412: Protéger du rayonnement solaire. Ne pas exposer à une température supérieure à 50 ℃.
  • P501: Éliminer le contenu et le récipient en conformité avec toutes réglementations locales, régionales, nationales, et internationales.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

RUST-OLEUM EUROPE

supplier

📍

Martin Mathys NV, Kolenbergstraat 23, B-3545 Zelem, Belgique

🌍

BE

📞

+32 (0) 13 460 200

📠

+32 (0) 13 460 201

Tor Coatings Limited

supplier

📍

Unit 21, White Rose Way, Follingsby Park, Gateshead, Tyne & Wear, NE10 8YX Royaume-Uni

🌍

GB

📞

+44 (0) 191 4106611

📠

+44 (0) 191 4920125

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Organisme de conseil/centre antipoison national

📞

+32 28083237

🌍

BE

🕒

24 / 7

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Ce mélange contient ≥ 1% de dioxyde de titane.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
butane (containing < 0,1 % butadiene (203-405-8), Note K)
EC: 203-448-7
106-97-8 10-25% ⚠️ Hazardous
hydrocarbures C9-C11, n-alcanes, isoalcanes, cycliques, aromatiques
EC: 919-857-5
N/A 10-25% ⚠️ Hazardous
propaan (Drijfgas (Arosol))
EC: 200-827-9
74-98-6 10-25% ⚠️ Hazardous
Tri Zinc Bis Orthophosphate
EC: 231-944-3
7779-90-0 1% ⚠️ Hazardous
nkoxide 1,2-benzisothiazool-3(2H)-on
EC: 215-222-5
1314-13-2 0.3% ⚠️ Hazardous

Additional Information

Dans l'état actuel des connaissances du fournisseur et dans les concentrations d'application, aucun autre ingrédient présent n'est classé comme dangereux pour la santé ou l'environnement, ni comme PTB ou vPvB, ni comme substance de degré de préoccupation équivalent, ni soumi à une limite d'exposition professionnelle et donc nécessiterait de figurer dans cette section.

Composition Notes

La classification annexe VI de dioxyde de titane ne s'applique pas à ce mélange selon la note 10.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Transporter la victime à l'extérieur et la maintenir au repos dans une position où elle peut confortablement respirer. Si l'on soupçonne que des fumées sont encore présentes, le sauveteur devra porter un masque adéquat ou un appareil de protection respiratoire autonome. S'il ne respire pas, en cas de respiration irrégulière ou d'arrêt respiratoire, que le personnel qualifié pratique la respiration artificielle ou administre de l'oxygène. Consulter un médecin. Si nécessaire, appeler un centre antipoison ou un médecin. En cas d'évanouissement, placez la personne en position latérale de sécurité et appelez un médecin immédiatement. Assurez-vous d'une bonne circulation d'air. Détacher tout ce qui pourrait être serré, comme un col, une cravate, une ceinture ou un ceinturon.

Symptoms:

Les symptômes néfastes peuvent éventuellement comprendre ce qui suit: irritation des voies respiratoires, toux, nausées ou vomissements, migraine, somnolence/fatigue, étourdissements/vertiges, évanouissement.

🖐️ Skin Contact

Laver soigneusement la peau au savon et à l'eau ou utiliser un nettoyant cutané reconnu. Retirer les vêtements et les chaussures contaminés. Consulter un médecin si des symptômes se développent. Laver les vêtements avant de les réutiliser. Laver soigneusement les chaussures avant de les remettre.

Symptoms:

Les symptômes néfastes peuvent éventuellement comprendre ce qui suit: irritation, sécheresse, gerçure.

👁️ Eye Contact

Rincer immédiatement les yeux à grande eau, en soulevant de temps en temps les paupières supérieures et inférieures. Vérifier si la victime porte des verres de contact et dans ce cas, les lui enlever. Continuez de rincer pendant 10 minutes au moins. Consulter un médecin.

Symptoms:

Les symptômes néfastes peuvent éventuellement comprendre ce qui suit: irritation, rougeur.

🍽️ Ingestion/Swallowing

Rincez la bouche avec de l'eau. Enlever les prothèses dentaires s'il y a lieu. Si une personne a avalé de ce produit et est consciente, lui faire boire de petites quantités d'eau. Si la personne est indisposée, cesser de la faire boire car des vomissements pourraient entraîner un risque supplémentaire. Ne pas faire vomir sauf indication contraire émanant du personnel médical. En cas de vomissement, maintenez la tête vers le bas pour empêcher le passage des vomissures dans les poumons. Consulter un médecin. Si nécessaire, appeler un centre antipoison ou un médecin. Ne rien faire ingérer à une personne inconsciente. En cas d'évanouissement, placez la personne en position latérale de sécurité et appelez un médecin immédiatement. Assurez-vous d'une bonne circulation d'air. Détacher tout ce qui pourrait être serré, comme un col, une cravate, une ceinture ou un ceinturon.

Symptoms:

Aucune donnée spécifique.

🚨 Immediate Medical Attention Required

Traitement symptomatique requis. Contacter immédiatement un spécialiste pour le traitement des intoxications, si de grandes quantités ont été ingérées ou inhalées.

Medical Treatment

Pas de traitement particulier.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Liquide. [Aérosol.]
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
Blanc. Brun. Bleu. Gris. Vert. Orange. Rouge. Jaune. [Pâle]
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
Ressemblant à un solvant [Faible]
📊 Odor Threshold
Non disponible.
🧪 Ph
Non applicable.
🧊 Melting Point
Non disponible.
Critical Property
💨 Boiling Point
Non disponible.
Critical Property
🔥 Flash Point
Vase clos: - 70°C (-94ºF) [Littérature]
Critical Property
📊 Freezing Point
Not available
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Non disponible.
💨 Vapor Pressure
400 kPa (3000 mm Hg) [calculé.]
📊 Vapor Density
>1 [Air = 1]
📊 Relative Density
0,81 à 0,88 [DIN 53217]
📊 Bulk Density
0,81 à 0,88 g/cm3 [20°C (68ºF)] [DIN 53217]
⚖️ Density
Not available
🔥 Flammability
Très inflammable en présence des matières ou des conditions suivantes : flammes nues, étincelles et décharge statique et chaleur. Légèrement inflammable en présence des matières ou des conditions suivantes : chocs et impacts mécaniques. Lors de l'utilisation, formation possible de mélange vapeur-air inflammable/ explosif. Les vapeurs peuvent parcourir une grande distance jusqu'à une source d'inflammation et provoquer un retour de flammes.
📊 Upper Explosive Limit
Seuil maximal: 9%
📊 Lower Explosive Limit
Seuil minimal: 2%
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Non disponible.
📊 Decomposition Temperature
Non disponible.
💧 Solubility
Non disponible.
📊 Partition Coefficient
Non applicable.
📊 Solubility In Water
Non disponible.
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
Non disponible.
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Utiliser uniquement dans un environnement bien aéré. Utiliser des enceintes fermées, une ventilation par aspiration à la source, ou d'autres systèmes de contrôle automatique intégrés afin de maintenir le seuil d'exposition du technicien aux contaminants en suspension dans l'air inférieur aux limites recommandées ou légales. Les moyens de contrôle automatiques intégrés devront permettre de maintenir les concentrations en gaz, en vapeur ou en poussière en dessous de tout seuil d'explosion. Utiliser un équipement de ventilation antidéflagrant.

🧤 Hand Protection

Lors de la manipulation de produits chimiques, porter en permanence des gants étanches et résistants aux produits chimiques conformes à une norme approuvée, si une évaluation du risque indique que cela est nécessaire. En prenant en compte les paramètres indiqués par le fabricant de gants, vérifier pendant l'utilisation que les gants conservent leurs propriétés protectrices. Il est noté que le temps de claquage des gants peut différer d'un fabricant à l'autre. En cas de mélanges constitués de plusieurs substances, il est impossible d'estimer de façon précise le délai de sécurité des gants. > 8 heures (temps avant transpercement) : caoutchouc nitrile (0.5mm) Les recommandations sur le ou les types de gants à utiliser lors de la manipulation du produit sont basées sur les informations provenant de la source suivante: EN374. L'utilisateur doit vérifier que les types de gants qu'il choisit de porter pour la manipulation de ce produit est le plus approprié et prend en compte les conditions d'utilisation particulières, conformément aux indications stipulées dans l'évaluation des risques de l'utilisateur.

👁️ Eye Protection

Utiliser une protection oculaire conforme à une norme approuvée dès lors qu'une évaluation du risque indique qu'il est nécessaire d'éviter l'exposition aux projections de liquides, aux fines particules pulvérisées, aux gaz ou aux poussières. Utiliser une protection oculaire homologuée EN 166. Si le contact est possible, porter les protections suivantes à moins que l'évaluation n'indique un degré supérieur de protection : lunettes de sécurité avec protections latérales.

😷 Respiratory Protection

En fonction du risque et de la possibilité d'une exposition, choisir un respirateur qui est conforme à la norme ou certification appropriée. Les appareils respiratoires doivent être utilisés conformément au programme de protection respiratoire afin de veiller à la pose conforme, la formation et d'autres aspects importants de l'utilisation. Recommandé: filtre de vapeurs organiques (Type A) et à particules (EN 140)

🦺 Skin/Body Protection

L'équipement de protection personnel pour le corps devra être choisi en fonction de la tâche à réaliser ainsi que des risques encourus, et il est recommandé de le faire valider par un spécialiste avant de procéder à la manipulation du produit. En cas de risque d'inflammation lié à l'électricité statique, porter des vêtements de protection antistatiques. Pour une protection maximale contre les décharges d'électricité statique, les vêtements doivent inclure une combinaison, des chaussures et des gants antistatiques. Pour plus d'informations sur les exigences et les méthodes d'essais des matières et des modèles, consulter la norme européenne EN 1149. Recommandé: Le personnel doit porter des vêtements antistatiques en fibres naturelles ou en fibres synthétiques résistant aux températures élevées.

🌍 Environmental Exposure Controls

Il importe de tester les émissions provenant des systèmes de ventilation ou du matériel de fabrication pour vous assurer qu'elles sont conformes aux exigences de la législation sur la protection de l'environnement. Dans certains cas, il sera nécessaire d'équiper le matériel de fabrication d'un épurateur de gaz ou d'un filtre ou de le modifier techniquement afin de réduire les émissions à des niveaux acceptables.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1950

📦 Proper Shipping Name

AÉROSOLS, inflammables

⚠️ Transport Hazard Class

2 2

🚛 ADR Transport Precautions

Transport avec les utilisateurs locaux : toujours transporter dans des conditionnements qui sont corrects et sécurisés. S'assurer que les personnes transportant le produit connaissent les mesures à prendre en cas d'accident ou de déversement accidentel.

🚢 IMDG Maritime Transport Precautions

Urgences F-D, S-U Remarques : ≤ 1L: Quantité limitée - IMDG 3.4

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for 7300 CombiColor Spuitbussen?

The signal word for this substance is "danger".

What is the physical form of 7300 CombiColor Spuitbussen?

7300 CombiColor Spuitbussen is a liquide. [aérosol.] with blanc. brun. bleu. gris. vert. orange. rouge. jaune. [pâle] color. It has ressemblant à un solvant [faible] odor.

What is the solubility of 7300 CombiColor Spuitbussen?

Non disponible.

What is 7300 CombiColor Spuitbussen used for?

Utilisation par les consommateurs, Usage industriel, Utilisation professionnelle

What are the hazard statements for 7300 CombiColor Spuitbussen?

This substance has 4 hazard statements: H222: Aérosol extrêmement inflammable. H229: Récipient sous pression: peut éclater sous l'effet de la chaleur. H336: Peut provoquer somnolence ou vertiges. H412: Nocif pour les organismes aquatiques, entraîne des effets néfastes à long terme.

What is the melting point of 7300 CombiColor Spuitbussen?

The melting point is Non disponible. and the boiling point is Non disponible..