NextSDS Logo
Safety Data Sheet FR

Propane

CAS 000074-98-6
EC 200-827-9

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Propane
Product Code
EIGA104
Chemical Name
Propane

Regulatory Identifiers

CAS Number
000074-98-6 Check regulations →
EC Number
200-827-9 Check regulations →
REACH No.
Limite d'enregistrement non atteinte

Identified Uses

Industriel et professionnel Faire une analyse des risques avant utilisation

Manufacturers & Suppliers

A

AIR LIQUIDE BELGE S.A./N.V.

manufacturer

Quai des Vennes, 8, B-4020 Liège Belgique-Belgie

Emergency Contacts

AIR LIQUIDE BELGE S.A./N.V.

04 349 89 89

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Gas Cat. 1 H220
Gaz sous pression H280

GHS Pictograms

GHS02 - Flammable

GHS02

GHS04 - Compressed gas

GHS04

Hazard Statements

H220 Gaz extrmement inflammable.
H280 Contient un gaz sous pression; peut exploser sous l'effet de la chaleur.

Precautionary Statements

P210 Tenir lcart de la chaleur, des tincelles, des flammes nues ou des surfaces chaudes. Ne pas fumer.
P377 Fuite de gaz enflamm: Ne pas teindre si la fuite ne peut pas tre arrte sans risque.
P381 liminer toutes les sources dignition si cela est faisable sans danger.
P403 Stocker dans un endroit bien ventil.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Substance
Chemical Name CAS Number Concentration Hazardous
Propane EC: 200-827-9 74-98-6 100% Yes

Note 1: List dans l'Annexe IV/V de Reich, exempt d'enregistrement Note 2: Limite d'enregistrement non atteinte Voir le texte complet des Phrases-R au chapitre 16

Notes

Ne contient pas d'autres composants ni impurets qui pourraient modifier la classification du produit.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Dplacer la victime dans une zone non contamine, en s'quipant d'un appareil respiratoire autonome. Laisser la victime au chaud et au repos. Appeler un mdecin. Pratiquer la respiration artificielle si la victime ne respire plus.

Symptoms: Peut causer l'asphyxie concentration leve. Les symptmes peuvent tre une perte de connaissance ou de motricit. La victime peut ne pas tre prvenue de l'asphyxie. Peut avoir des effets narcotiques faible concentration. Les symptmes peuvent tre des tourdissements, des maux de tte, des nauses et une perte de coordination.

Skin contact

En cas de renversement de liquide: rincer l'eau pendant au moins 15 minutes.

Eye contact

En cas de renversement de liquide: rincer l'eau pendant au moins 15 minutes.

Immediate Medical Attention

Appeler un mdecin.

Medical Treatment

Pratiquer la respiration artificielle si la victime ne respire plus.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Assurer une ventilation approprie.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Metal Corrosion
---
Flammability
1,7 9,5
Molecular Weight
44
Upper Explosive Limit
9,5
Crystallisation Point
---
Vapor Density
---
Kinematic Viscosity
---
Explosive Limits
---
Partition Coefficient
---
Freezing Point
---
Auto Ignition Temperature
470
Lower Explosive Limit
1,7
Relative Evaporation Rate
---
State Under Standard Conditions
---
Relative Density
0,58
Physical State Data
gas
Boiling Point
-42,1
Solubility In Water
75
Decomposition Temperature
---
Odor
Doucetre. Difficilement dtectable l'odeur faible concentration. Produit d'odeur infecte souvent ajout.
Appearance
---
Dynamic Viscosity
---
Voc Content
---
Evaporation Rate
---
Solubility In Fat
---
Vapor Pressure
8,3 bar
Melting Point
-188
Flash Point
---
Density
---
Ph
---
Softening Point
---
Bulk Density
---
Solubility
---
Solidification Point
---
Odor Threshold
---
Cloud Point
---
Form
---
Properties Status
---
Physical State
Gaz.
Colour Intensity
---
Colour
Gaz incolore.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1978
Shipping Name
PROPANE
Transport Class
2
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Propane?

The signal word is danger.

What is the physical form of Propane?

Propane is a gaz. with gaz incolore. color. It has doucetre. difficilement dtectable l'odeur faible concentration. produit d'odeur infecte souvent ajout. odor.

What is Propane used for?

Industriel et professionnel Faire une analyse des risques avant utilisation

What are the hazard statements for Propane?

This substance has 2 hazard statements:

  • H220: Gaz extrmement inflammable.
  • H280: Contient un gaz sous pression; peut exploser sous l'effet de la chaleur.

What is the melting point of Propane?

The melting point is -188 and the boiling point is -42,1.