Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
MOTIP INDUSTRIAL COATING GALVANISATION A FROID BRILLANT 500 ML commonly used su21 utilisations par des consommateurs: mnages privs / public gnral / consommateurs; su22 utilisations professionnelles: domaine public (administration, ducation, spectacle, services, artisans); pc9a revtements et peintures, solvants, diluants; proc7 pulvrisation dans des installations industrielles; proc11 pulvrisation en dehors d'installations industrielles; peinture.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS09
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H222: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur.
- H229: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur.
- H319: Provoque une svre irritation des yeux.
- H336: Peut provoquer somnolence ou vertiges.
- H411: Toxique pour les organismes aquatiques, entrane des effets nfastes long terme.
Precautionary Statements
- P101: En cas de consultation d'un mdecin, garder disposition le rcipient ou l'tiquette.
- P102: Tenir hors de porte des enfants.
- P210: Tenir l'cart de la chaleur, des surfaces chaudes, des tincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
- P211: Ne pas vaporiser sur une flamme nue ou sur toute autre source d'ignition.
- P251: Ne pas perforer, ni brler, mme aprs usage.
- P260: Ne pas respirer les arosols.
- P264: Se laver les mains soigneusement aprs manipulation.
- P271: Utiliser seulement en plein air ou dans un endroit bien ventil.
- P273: viter le rejet dans l'environnement.
- P280: Porter des gants de protection / un quipement de protection des yeux.
- P305+P351+P338: EN CAS DE CONTACT AVEC LES YEUX: Rincer avec prcaution l'eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent tre facilement enleves. Continuer rincer.
- P312: Appeler un CENTRE ANTIPOISON/un mdecin en cas de malaise.
- P337+P313: Si l'irritation oculaire persiste: consulter un mdecin.
- P410+P412: Protger du rayonnement solaire. Ne pas exposer une temprature suprieure 50 C.
- P501: liminer le contenu / rcipient conformment la rglementation rgionale.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
European Aerosols B.V.
manufacturer
Wolfraamweg 2 NL-8471 XC Wolvega Pays-Bas
NL
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
+31 (0)561-694400
NL
09:00h - 17:00h
ORFILA (INRS)
+ 33 (0)1 45 42 59 59
FR
24 heures sur 24 et 7 jours sur 7
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Mlange des substances mentionnes la suite avec des additifs non dangereux.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| oxyde de dimthyle EC: 204-065-8 | 115-10-6 | 25-50% | ⚠️ Hazardous |
| actone EC: 200-662-2 | 67-64-1 | 20-25% | ⚠️ Hazardous |
| Hydrocarbures, C9, aromatiques EC: 918-668-5 | N/A | 12.5-20% | ⚠️ Hazardous |
| zinc en poudre - poussires de zinc (stabilises) EC: 231-175-3 | 7440-66-6 | 5-10% | ⚠️ Hazardous |
| Aluminium en poudre (stabilise) EC: 231-072-3 | 7429-90-5 | 2.5-5% | ⚠️ Hazardous |
| xylne EC: 905-588-0 | N/A | 2.5-5% | ⚠️ Hazardous |
| naphta lourd (ptrole), hydrotrait EC: 265-150-3 | 64742-48-9 | 2.5% | ⚠️ Hazardous |
| oxyde de zinc EC: 215-222-5 | 1314-13-2 | 0.5% | ⚠️ Hazardous |
Additional Information
CAS 7429-90-5, EINECS 231-072-3, Index 013-002-00-1: Note T CAS 7440-66-6, EINECS 231-175-3, Index 030-001-01-9: Note T Pour le libell des phrases de risque cites, se rfrer au chapitre 16.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
🫁 Inhalation Exposure
Donner de l'air frais, consulter un mdecin en cas de troubles.
👁️ Eye Contact
Rincer les yeux, pendant plusieurs minutes, sous l'eau courante en cartant bien les paupires. Si les troubles persistent, consulter un mdecin.
🍽️ Ingestion/Swallowing
Boire de l'eau en abondance et donner de l'air frais. Consulter immdiatement un mdecin.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
🧤 Hand Protection
Gants de protection Matériau des gants: Butylcaoutchouc Le choix de gants appropriés ne dépend pas seulement du matériau, mais également d'autres critères de qualité qui peuvent varier d'un fabricant à l'autre. Temps de pénétration du matériau des gants: Gants en caoutchouc butyle avec une épaisseur de 0,4 mm sont résistantes : Acétone: 480 min Acétate de n-butyle: 60 min Acétate d'éthyle: 170 min Xylène: 42 min Les gants en caoutchouc butyle d'une épaisseur de 0,4 mm résistent aux solvants pendant 42 à 480 minutes. Comme mesure de protection, nous recommandons que les utilisateurs et les personnes responsables de la sécurité du travail présupposent une durée de résistance aux solvants de 42 heures. Si l'on examine les données au chapitre 3 de cette fiche de données de sécurité, on peut présupposer une durée de résistance plus longue dans certains cas.
😷 Respiratory Protection
En cas d'exposition faible ou de courte durée, utiliser un filtre respiratoire; en cas d'exposition intense ou durable, utiliser un appareil de respiration indépendant de l'air ambiant. Filtre A2/P3
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
🏷️ UN Number
UN1950
📋 Packing Group
nant
🚢 IMDG Maritime Transport Precautions
Attention: Gaz.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for MOTIP INDUSTRIAL COATING GALVANISATION A FROID BRILLANT 500 ML?
The signal word for this substance is "danger".
What is the physical form of MOTIP INDUSTRIAL COATING GALVANISATION A FROID BRILLANT 500 ML?
MOTIP INDUSTRIAL COATING GALVANISATION A FROID BRILLANT 500 ML is a aérosol with argent color. It has de type solvant odor.
What is MOTIP INDUSTRIAL COATING GALVANISATION A FROID BRILLANT 500 ML used for?
SU21 Utilisations par des consommateurs: Mnages privs / public gnral / consommateurs; SU22 Utilisations professionnelles: Domaine public (administration, ducation, spectacle, services, artisans); PC9a Revtements et peintures, solvants, diluants; PROC7 Pulvrisation dans des installations industrielles; PROC11 Pulvrisation en dehors d'installations industrielles; Peinture
What are the hazard statements for MOTIP INDUSTRIAL COATING GALVANISATION A FROID BRILLANT 500 ML?
This substance has 5 hazard statements: H222: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur. H229: Arosol extrmement inflammable. Rcipient sous pression: peut clater sous leffet de la chaleur. H319: Provoque une svre irritation des yeux. H336: Peut provoquer somnolence ou vertiges. H411: Toxique pour les organismes aquatiques, entrane des effets nfastes long terme.
What is the melting point of MOTIP INDUSTRIAL COATING GALVANISATION A FROID BRILLANT 500 ML?
The melting point is Non déterminé. and the boiling point is Non applicable, s'agissant d'un aérosol..