NextSDS Logo
Safety Data Sheet FR

SUPERCUT II

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SUPERCUT II
Product Form
Aérosol

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubrifiants

Manufacturers & Suppliers

CRC Industries Europe bvba logo

CRC Industries Europe bvba

manufacturer

Touwslagerstraat 1, 9240 Zele

+32(0)52/45.60.11

http://www.crcind.com

C

CRC Industries Finland Oy

distributor

Asemanrinne 13, 08500 Lohja

+358/(19)32.921

C

CRC Industries France

distributor

6, avenue du marais, B.P. 90028, 95102 Argenteuil Cedex

01.34.11.20.00

C

CRC Industries Deutschland GmbH

distributor

Südring 9, D-76473 Ilfezheim

(07229) 303.0

C

CRC INDUSTRIES IBERIA S.L.U.

distributor

GREMIO DEL CUERO-PARC.96, POLIGONO INDUSTR. DE HONTORIA, 40195 SEGOVIA

0034/921.427.546

C

CRC Industries Sweden

distributor

Kryptongatan 14, 431 53 Mölndal

0046/31 706 84 80

Emergency Contacts

CRC Industries Europe, Belgium

+32(0)52/45.60.11

heures de bureau

ANGERS

02 41 48 21 21

BORDEAUX

05 56 96 40 80

LILLE

0 825 812 822

LYON

04 72 11 69 11

MARSEILLE

04 91 75 25 25

NANCY

03 83 32 36 36

PARIS

01 40 05 48 48

RENNES

02 99 59 22 22

STRASBOURG

03 88 37 37 37

TOULOUSE

05 61 77 74 47

Centre Antipoisons

070 - 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

non-classifi
INFLAMMABLE
non-classifi

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
huile minerale (IP 346 DMSO extract < 3%) --- 75 - 100% Yes
tetrafluoroethane EC: 212-377-0 811-97-2 5 - 10% Yes
polysulfides, di-tert-dodecyl EC: 270-335-7 68425-15-0 1 - 5% Yes
CO2 EC: 204-696-9 124-38-9 1% Yes
Benzenepropanoic acid, 4-hydroxy- EC: 207-931-3 501-97-3 1% Yes
zinc alkyldithiophosphate EC: 272-028-3 68649-42-3 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Air frais, tenir calme et au chaud.

Symptoms: L'inhalation excessive de vapeurs de solvant peut provoquer nausée, maux de tête et étourdissements.

Skin contact

Enlever immédiatement tout vêtement contaminé et mouiller la peau atteinte copieusement avec de l'eau. Ensuite laver avec du savon et de l'eau.

Symptoms: Peut entraîner irritation. Symptômes: rougeur, douleur.

Eye contact

Si la substance a touché les yeux, les laver immédiatement avec beaucoup d'eau.

Symptoms: Peut entraîner irritation. Symptômes: rougeur, douleur.

Ingestion

En cas d'ingestion accidentelle, ne pas faire vomir et consulter un médecin. Laisser jeun.

Symptoms: Risque de pneumonie. Symptômes: maux de gorge, douleurs abdominales, nausées, vomissements.

Immediate Medical Attention

Faire appel à un médecin si l'irritation persiste (yeux, peau) ou si des effets négatifs apparaissent (inhalation). En cas d'ingestion accidentelle, consulter un médecin. En cas de malaise général ou si les symptômes persistent, consulter un médecin (si possible lui montrer l'étiquette).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Assurer une ventilation adéquate. Tenir loin de la chaleur et de sources d'ignition. Éviter l'accumulation de charges électrostatiques.

Hands

Porter des gants (néoprène).

Eyes

Porter des lunettes.

Respiratory

En cas de ventilation insuffisante porter un appareil respiratoire approprié. Masque antigaz contre les vapeurs organique (type A ou AX).

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Density
---
Physical State Data
liquid
Density
---
State Under Standard Conditions
---
Flash Point
- 170 C
Relative Evaporation Rate
---
Decomposition Temperature
---
Ph
Non applicable.
Bulk Density
---
Solubility In Water
Insoluble dans l'eau
Kinematic Viscosity
---
Voc Content
50 g/l
Partition Coefficient
---
Odor Threshold
---
Solubility In Fat
---
Physical State
Liquide sous pression.
Auto Ignition Temperature
- 200 C
Vapor Pressure
Non connu.
Solidification Point
---
Softening Point
---
Explosive Limits
---
Colour Intensity
---
Evaporation Rate
Non applicable.
Dynamic Viscosity
55.9 mPa.s (@ 20C).
Metal Corrosion
---
Odor
Odeur caractristique.
Appearance
---
Lower Explosive Limit
Non connu.
Molecular Weight
---
Properties Status
---
Cloud Point
---
Crystallisation Point
---
Form
---
Colour
Ambr.
Flammability
---
Melting Point
---
Solubility
---
Upper Explosive Limit
Non connu.
Relative Density
0.879 g/cm3 (@ 20C).
Boiling Point
Non connu.
Freezing Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS, flammable
Transport Class
2.1
Packing Group
Non applicable.
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SUPERCUT II?

The signal word is no signal word.

What is the physical form of SUPERCUT II?

SUPERCUT II is a liquide sous pression. with ambr. color. It has odeur caractristique. odor.

What is SUPERCUT II used for?

Lubrifiants