NextSDS Logo
Su

Supercut

WARNING Aérosol SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Supercut
Product Code
BDS002293AE

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Lubrifiants

Overview

Supercut commonly used lubrifiants.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Aerosol Category 2 H223
Aerosol Category 2 H229
Skin Sens. Category 1B H317

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H223: Aérosol inflammable.
  • H229: Récipient sous pression: peut éclater sous l’effet de la chaleur.
  • H317: Peut provoquer une allergie cutanée.

Precautionary Statements

  • P102: Tenir hors de portée des enfants.
  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'ignition. Ne pas fumer.
  • P211: Ne pas vaporiser sur une flamme nue ou sur toute autre source d’ignition.
  • P251: Ne pas perforer, ni brûler, même après usage.
  • P261: Éviter de respirer les brouillards/vapeurs.
  • P280: Porter des gants de protection.
  • P410 + P412: Protéger du rayonnement solaire. Ne pas exposer à une température supérieure à 50 °C/122 °F.
  • P501: Éliminer le contenu/récipient conformément aux réglementations locales/régionales/nationales/internationales.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

CRC Industries Europe bv company logo - Safety Data Sheet supplier organization

CRC Industries Europe bv

undefined

Touwslagerstraat 1 9240 Zele Belgique

BE

+32(0)52/45.00.34

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CRC Industries Europe bv

+32(0)52/45.60.11

BE

heures de bureau: 9-17h CET

Numéro ORFILA (INRS)

+ 33 (0) 1 45 42 59 59

FR

Disponible 24 heures sur 24.

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Toutes les concentrations sont données en pourcentage massique sauf pour les ingrédients sous forme gazeuse. Les concentrations des gaz sont exprimées en pourcentage volumique.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Sulfonates de calcium dérivés du pétrole
EC: 263-093-9
61789-86-4 1% Hazardous
Acide benzènesulfonique , mono-C16-24-alkyl derivitives, calcium salts
EC: 274-263-7
70024-69-0 0.5% Hazardous
2,2'-(octadéc-9-énylimino)biséthanol
EC: 246-807-3
25307-17-9 0.1% Hazardous
Distillats paraffiniques légers de pétrole hydrotraités
EC: 265-158-7
64742-55-8 10-25% Hazardous
Distillats paraffiniques lourds (pétrole), hydrotraités
EC: 265-157-1
64742-54-7 5-10% Hazardous
Polysulfures de di-tert-dodécyle
EC: 270-335-7
68425-15-0 5% Hazardous
acide benzènesulfonique, dérivés alkyles en C10-16, sels de calcium
EC: 271-529-4
68584-23-6 1% Hazardous

Composition Notes

Le texte intégral de toutes les mentions H est présenté en section 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Sortir au grand air. Contacter un médecin si les symptômes se développent ou persistent.

Skin Contact

Enlever immédiatement les vêtements souillés et laver la peau avec de l'eau et du savon. En cas d'eczéma ou d'autres problèmes cutanés : consulter un médecin et apporter cette fiche.

Symptoms:

Peut provoquer une allergie cutanée. Dermatite. Éruption cutanée.

Eye Contact

Rincer avec de l'eau. Consulter un médecin si une irritation se développe et persiste.

Ingestion/Swallowing

Dans le cas improbable d'une ingestion, contacter un médecin ou un centre antipoison. Rincer la bouche.

Immediate Medical Attention Required

Contacter un médecin si les symptômes se développent ou persistent (inhalation). Consulter un médecin si une irritation se développe et persiste (yeux). En cas d'eczéma ou d'autres problèmes cutanés : consulter un médecin et apporter cette fiche. Dans le cas improbable d'une ingestion, contacter un médecin ou un centre antipoison.

Medical Treatment

Assurer des soins généraux et traiter en fonction des symptômes. Garder la victime sous observation.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Brouillard d'eau. Mousse. Agent chimique sec. Dioxyde de carbone (CO2).

Unsuitable Extinguishing Media

En cas d'incendie ne pas utiliser de jet d'eau car celà dispersera le feu.

Specific Fire Hazards

Aérosol inflammable. Contenu sous pression. Le récipient pressurisé peut exploser lorsqu'il est exposé à la chaleur ou à une flamme. En cas d'incendie, des gaz dangereux pour la santé peuvent être produits.

Fire Fighting Instructions

Éloigner les récipients de l'incendie si cela peut se faire sans risque. Les récipients doivent être refroidis à l'eau pour éviter toute accumulation de pression de vapeur. En cas d'incendie majeur dans la zone de chargement : utiliser des supports de tuyaux autonomes et des lances à eau autonomes; sinon, se retirer et laisser brûler. Employer des méthodes normales de lutte contre l'incendie et tenir compte des dangers associés aux autres substances présentes. En cas d'incendie et/ou d'explosion, ne pas respirer les fumées.

Firefighter Protection Equipment

Les pompiers doivent porter un équipement de protection standard, notamment vêtement ignifuge, casque à masque facial, gants, bottes en caoutchouc et, dans les espaces clos, un appareil respiratoire autonome.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Pour les non-secouristes: Éviter de respirer les brouillards/vapeurs. Ne pas toucher les récipients endommagés ou le produit déversé à moins d'être vêtu d'une tenue protectrice appropriée. Pour les secouristes: Tenir à l’écart le personnel superflu. Aérer les espaces fermés avant d'y entrer. Éviter de respirer les brouillards/vapeurs. Prévenir les autorités locales si des fuites significatives ne peuvent pas être contenues. Bloquer la fuite si cela peut se faire sans risque. Déplacer la bonbonne vers une zone sûre et ouverte si la fuite est irréparable.

Small Spill Procedures

Essuyer avec une matière absorbante (p.ex. tissu, laine). Nettoyer à fond la surface pour éliminer toute contamination résiduelle.

Environmental Precautions

Éviter le rejet à l'égout et dans les environnements terrestres et les cours d'eau.

Cleanup Methods

Essuyer avec une matière absorbante (p.ex. tissu, laine). Nettoyer à fond la surface pour éliminer toute contamination résiduelle. Après avoir récupéré le produit, rincer la zone à l'eau.

Cleanup Materials:

matière absorbante (p.ex. tissu, laine)

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Freezing Point
Donnée inconnue.
Melting Point
Donnée inconnue.
Critical Property
Properties Status
Not available
Decomposition Temperature
Donnée inconnue.
Relative Density
0,88 g/cm3 à 15 °C
Solubility In Water
Donnée inconnue.
Colour Intensity
Not available
Voc Content
50 g/l
Physical State
Aérosol
Critical Property
State Under Standard Conditions
Not available
Solubility
Donnée inconnue.
Solidification Point
Not available
Vapor Pressure
6720,7 hPa
Vapor Density
Donnée inconnue.
Molecular Weight
Not available
Flammability
Donnée inconnue.
Appearance
Not available
Crystallisation Point
Not available
Evaporation Rate
Not available
Auto Ignition Temperature
> 200 °C (> 392 °F)
Boiling Point
-19 °C (-2,2 °F)
Critical Property
Upper Explosive Limit
Not available
Cloud Point
Not available
Dynamic Viscosity
55,9 mPa·s à 20 °C 23,09 mPa·s à 40°C
Kinematic Viscosity
Donnée inconnue.
Metal Corrosion
Not available
Explosive Limits
Not available
Ph
Donnée inconnue.
Relative Evaporation Rate
Not available
Partition Coefficient
Not available
Flash Point
> 170,0 °C (> 338,0 °F)
Critical Property
Odor
Odeur caractéristique
Physical State Data
aerosol
Lower Explosive Limit
Not available
Colour
Vert
Form
Aérosol
Softening Point
Not available
Density
Not available
Bulk Density
Not available
Odor Threshold
Not available
Solubility In Fat
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Récipient sous pression: ne pas perforer, ni brûler, même après usage.

Ne pas utiliser si le bouton de pulvérisation est manquant ou défectueux.

Ne pas pulvériser contre une flamme nue ou tout autre objet incandescent.

Ne pas fumer pendant l'utilisation du produit ou attendre que la surface vaporisée soit totalement sèche.

Ne pas couper, souder, braser, percer, broyer ou exposer les récipients à la chaleur, à une flamme, à des étincelles ou à toute autre source d'ignition.

Ne pas réutiliser des récipients vides.

Éviter de respirer les brouillards/vapeurs.

Éviter le contact avec les yeux, la peau et les vêtements.

Éviter toute exposition prolongée.

Porter un équipement de protection approprié.

Suivre les règles de bonnes pratiques chimiques.

Storage Conditions

Récipient sous pression.

A protéger contre les rayons solaires et ne pas exposer à une température supérieure à 50 °C.

Ne pas perforer, incinérer ou broyer.

Ne pas manipuler ou stocker à proximité d'une flamme nue, d'une source de chaleur ou toute autre source d'ignition.

Cette matière peut accumuler des charges statiques pouvant causer des étincelles et devenir une source d'ignition.

General Hygiene Measures

Suivre les règles de bonnes pratiques chimiques.

Fire Prevention Measures

Ne pas pulvériser contre une flamme nue ou tout autre objet incandescent. Ne pas fumer pendant l'utilisation du produit ou attendre que la surface vaporisée soit totalement sèche. Ne pas couper, souder, braser, percer, broyer ou exposer les récipients à la chaleur, à une flamme, à des étincelles ou à toute autre source d'ignition. Ne pas manipuler ou stocker à proximité d'une flamme nue, d'une source de chaleur ou toute autre source d'ignition.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Assurer une bonne ventilation générale. Le taux de renouvellement d'air devrait être adapté aux conditions. Si c'est approprié, clôtures de processus d'utilisation, ventilation d'échappement locale, ou d'autres commandes de technologie pour maintenir les niveaux aéroportés au-dessous des limites recommandées d'exposition. Si des limites d'exposition n'ont pas été établies, maintenez les niveaux aéroportés à un niveau acceptable.

Hand Protection

Pendant usage du produit porter des gants de protection contre les produits chimiques (norme EN 374). La durée de résistance au perçage du gant devrait être plus importante que la durée d'utilisation du produit. Si le travail dure plus longtemps, changer les gants. Les gants en néoprène sont recommandés.

Eye Protection

Utiliser une protection oculaire conforme à la norme EN 166. Perter des lunettes de sécurité à écrans latéraux.

Respiratory Protection

En cas de ventilation insuffisante, porter un appareil respiratoire approprié. Respirateur à cartouche chimique pour les vapeurs organiques. (Type filtre A)

Skin/Body Protection

Porter des vêtements appropriés résistant aux produits chimiques. L'emploi d'un tablier imperméable est recommandé.

Environmental Exposure Controls

Vérifier la conformité des émissions de la ventilation ou de l'équipement de procédé aux exigences de la réglementation relative à la protection de l'environnement. Il peut être nécessaire d'installer des épurateurs ou des filtres ou d'effectuer des modifications techniques sur l'équipement de procédé pour réduire les émissions jusqu'à des teneurs acceptables.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Ce produit est stable dans des conditions normales.

Reactivity

Le produit est stable et non réactif dans des conditions normales d’utilisation, de stockage et de transport.

Hazardous Reactions

Pas de réactions dangereuses connues dans les conditions normales d'utilisation.

Conditions to Avoid

Éviter les températures élevées.

Incompatible Materials

Agents oxydants forts.

Hazardous Decomposition Products

Oxydes de carbone.

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Product Disposal Recommendations

Eliminer le produit conformément à la réglementation locale en vigueur. Recueillir et réutiliser ou éliminer dans des récipients scellés en décharge agréée. Éliminer le contenu/récipient conformément aux réglementations locales/régionales/nationales/internationales. Détruire conformément à toutes les réglementations applicables.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1950

Proper Shipping Name

Aérosols, inflammables

Transport Hazard Class

2.1

Packing Group

Non affect.

ADR Transport Precautions

Consulter les instructions de sécurité, la FDS et les procédures d'urgence avant toute manipulation.

IMDG Maritime Transport Precautions

Consulter les instructions de sécurité, la FDS et les procédures d'urgence avant toute manipulation.

IATA Air Transport Precautions

Consulter les instructions de sécurité, la FDS et les procédures d'urgence avant toute manipulation.

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Supercut?

The signal word for this substance is "warning".

What is the physical form of Supercut?

Supercut is a aérosol with vert color. It has odeur caractéristique odor.

What is the solubility of Supercut?

Donnée inconnue.

What is Supercut used for?

Lubrifiants

What are the hazard statements for Supercut?

This substance has 3 hazard statements: H223: Aérosol inflammable. H229: Récipient sous pression: peut éclater sous l’effet de la chaleur. H317: Peut provoquer une allergie cutanée.

What is the melting point of Supercut?

The melting point is Donnée inconnue. and the boiling point is -19 °C (-2,2 °F).