NextSDS Logo
Bo

BossCover SprayBond+ Cleaner Spuitbus 500ml

DANGER SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
BossCover SprayBond+ Cleaner Spuitbus 500ml
Product Form
aerosol

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
H1VX-71EP-730R-K48H

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Koudreinigingsmiddel

Overview

BossCover SprayBond+ Cleaner Spuitbus 500ml is a aerosol substance commonly used koudreinigingsmiddel.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Aerosol Category 1 H222
Aerosol Category 1 H229
Aquatic Chronic Category 2 H411
Skin Irr. Category 2 H315
STOT SE Category 3 H336
Asp. Tox. Category 1 H304

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Zeer licht ontvlambare aerosol.
  • H229: Houder onder druk: kan open barsten bij verhitting.
  • H315: Veroorzaakt huidirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H411: Giftig voor in het water levende organismen, met langdurige gevolgen.
  • H304: Kan dodelijk zijn als de stof bij inslikken in de luchtwegen terechtkomt.

Precautionary Statements

  • P101: Bij het inwinnen van medisch advies, de verpakking of het etiket ter beschikking houden.
  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P211: Niet in een open vuur of andere ontstekingsbronnen spuiten.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P260: Nevel/damp/spuitnevel niet inademen.
  • P271: Alleen buiten of in een goed geventileerde ruimte gebruiken.
  • P273: Voorkom lozing in het milieu.
  • P280: Beschermende handschoenen / oogbescherming dragen.
  • P302+P352: Bij contact met de huid: met veel water en zeep wassen.
  • P304+P340: Na inademing: de persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.
  • P312: Bij onwel voelen een ANTIGIFCENTRUM / arts raadplegen.
  • P403: Op een goed geventileerde plaats bewaren.
  • P410+P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 ℃ / 122 °F
  • P501: De inhoud en de verpakking verwerken volgens de plaatselijke / regionale / nationale / internationale voorschriften.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

BossCover Nederland company logo - Safety Data Sheet supplier organization

BossCover Nederland

national supplier

📍

De Poort 21, 4411 PB Rilland

🌍

NL

📞

+ 31 113 55 77 83

BossCover België company logo - Safety Data Sheet supplier organization

BossCover België

national supplier

📍

Wijtschotbaan 7, 2900 Schoten

🌍

BE

📞

+32 03 328 00 00

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Nationaal Vergiftigingen Informatie Centrum (NVIC)

📞

088-755 8000

🌍

NL

💡

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen

Antigifcentrum

📞

070 245 245

🌍

BE

💡

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen

Antigifcentrum

📞

8002 5500

🌍

LU

💡

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mengsel

General Composition

Reinigingsmiddel

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Koolwaterstoffen, C6-C7, n-alkanen, iso-alkanen, cyclische, <5% n- hexaan
EC: 921-024-6
N/A 75-100% ⚠️ Hazardous
2-propanol
EC: 200-661-7
67-63-0 2.5-10% ⚠️ Hazardous
Koolstofdioxide Koolzuurgas, CO2, samengeperst
EC: 204-696-9
124-38-9 2.5-10% ⚠️ Hazardous
alifatische koolwaterstoffen N/A 30% ✓ Non-hazardous

Additional Information

Voor Aerosolen en van een vaste verstuiver voorziene houders die stoffen of mengsels bevatten die als gevaarlijk bij aspiratie zijn ingedeeld, is geen etikettering voor dat gevaar vereist. De tekst van de hier vermelde gevarenaanduidingen is te raadplegen in hoofdstuk 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Bij bewusteloosheid ligging en vervoer in stabiele zijligging. Als het slachtoffer niet ademt: Voer mond-op-mond of mond-op-neus reanimatie uit, neem onmiddellijk contact op met de noodarts.

🖐️ Skin Contact

Onmiddellijk met water en zeep afwassen en goed naspoelen.

👁️ Eye Contact

Ogen bij geopend ooglid meerdere minuten met stromend water spoelen en dokter raadplegen.

🍽️ Ingestion/Swallowing

Geen braken teweegbrengen en onmiddellijk medische hulp inschakelen.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Waternevel, bluspoeder, kooldioxyde, alcoholbestendig schuim.

Unsuitable Extinguishing Media

Krachtige waterstraal.

⚠️ Specific Fire Hazards

Geen verdere relevante informatie verkrijgbaar.

🛡️ Firefighter Protection Equipment

Ademhalingstoestel aantrekken.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

🌍 Environmental Precautions

Doordringen tot in afvalwater, riolering, putten of kelders verhinderen. Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Not available
📊 Physical State Data
Not available
📊 State Under Standard Conditions
Not available
👁️ Appearance
Aerosol
🎨 Colour
Volgens productomschrijving
📊 Colour Intensity
Not available
📊 Form
Aerosol
👃 Odor
Karakteristiek
📊 Odor Threshold
Niet bepaald
🧪 Ph
Het mengsel is apolair/aprotisch.
🧊 Melting Point
Niet bepaald
Critical Property
💨 Boiling Point
82 °℃ (67-63-0 2-propanol)
Critical Property
🔥 Flash Point
-9 ℃
Critical Property
📊 Freezing Point
Niet bepaald
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Niet bruikbaar
💨 Vapor Pressure
5.500 hPa
📊 Vapor Density
Niet bepaald
📊 Relative Density
Niet bepaald
📊 Bulk Density
Not available
⚖️ Density
0,72 g/cm3
Critical Property
🔥 Flammability
Zeer licht ontvlambare aerosol.
📊 Upper Explosive Limit
12 Vol %
📊 Lower Explosive Limit
0,8 Vol %
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
> 200 °℃
📊 Decomposition Temperature
Not available
💧 Solubility
Niet resp. gering mengbaar.
📊 Partition Coefficient
Niet bepaald
📊 Solubility In Water
Niet resp. gering mengbaar.
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
vervalt
📊 Dynamic Viscosity
Niet bepaald
📊 Kinematic Viscosity
≤ 20,5 mm2/s, 40 ℃
📊 Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

⚠️ Handling Precautions

• Voor goede ventilatie/afzuiging op de werkplaatsen zorgen.

• Niet spuiten in de richting van een vlam of gloeiend voorwerp.

• Ontstekingsbronnen op afstand houden - niet roken.

• Maatregelen treffen tegen ontlading van statische elektriciteit.

• Houder onder druk.

• Beschermen tegen de zon en niet blootstellen aan een hogere temperatuur dan 50℃.

• Ook na gebruik niet doorboren of verbranden.

🏪 Storage Conditions

• Op een koele plaats bewaren.

• Koel en droog bewaren in goed gesloten vaten.

• Tegen hitte en directe zonnestralen beschermen.

🔥 Fire Prevention Measures

Ontstekingsbronnen op afstand houden - niet roken.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Algemene ventilatie. Bij onvoldoende ventilatie ademhalingsbescherming.

🧤 Hand Protection

Veiligheidshandschoenen. Handschoenen bestand tegen oplosmiddelen. Permeatiedoorbraaktijden volgens EN374-3:2003 (minuten) > 480 minuten. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Handschoenmateriaal: Nitrilrubber. Aanbevolen materiaaldikte: ≥ 0,5 mm. Voor continu contact bevelen wij handschoenen aan met een doorbraaktijd van minstens 240 minuten, waarbij de voorkeur gegeven wordt aan een doorbreektijd van meer dan 480 minuten. Voor kortdurende of spatbescherming bevelen we hetzelfde aan. Voor een langdurig contact zijn handschoenen uit de volgende materialen geschikt: Butylrubber. Voor een contact van maximaal 15 minuten zijn handschoenen uit de volgende materialen geschikt: Butylrubber.

👁️ Eye Protection

Nauw aansluitende veiligheidsbril. Veiligheidsbril (EN166).

😷 Respiratory Protection

Filter A2/P2. Bij onvoldoende ventilatie ademhalingsbescherming.

🦺 Skin/Body Protection

Draag geschikte beschermende arbeidskleding (EN-13034/6). Volledig huid bedekkende antistatische, chemicalien- en oliebestendige kledij en veiligheidsschoenen worden aanbevolen (EN1149; EN340&En ISO 13688; EN13034-6).

🌍 Environmental Exposure Controls

Gebruik een geschikte container om milieuverontreiniging te voorkomen.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Geen afbraak bij gebruik volgens voorschrift.

⚠️ Hazardous Reactions

Geen gevaarlijke reacties bekend.

🧪 Incompatible Materials

Oxiderende stoffen.

💨 Hazardous Decomposition Products

Geen gevaarlijke ontbindingsproducten bekend.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

🌱 Toxiciteit

Koolwaterstoffen, C6-C7, n-alkanen, iso-alkanen, cyclische, <5% n-hexaan NOELR (72h) 3 mg/l (Pseudokirchneriella subcapitata) EL50 (48h) 3 mg/l (Daphnia magna) EL50 (72h) 30-100 mg/l (Pseudokirchneriella subcapitata) LL50 (96h) 11,4 mg/l (Oncorhynchus mykiss) NOEC (21 days) 0,17 mg/l (Daphnia magna) LOEC (21 days) 0,32 mg/l (Daphnia magna) 67-63-0 2-propanol EC50 >100 mg/l (Bacteria) LOEC (8 days) 1000 mg/l (Algae) LC50 (96h) 9640 mg/l (Pimephales promelas) LC50 (24h) 9714 mg/l (Daphnia magna)

🌱 Persistentie en afbreekbaarheid

Niet makkelijk biologisch afbreekbaar.

🌱 Bio accumulatie

Geen verdere relevante informatie beschikbaar.

🌱 Mobiliteit in de bodem

Geen verdere relevante informatie beschikbaar.

🌱 Resultaten van PBT- en zPzB-beoordeling

PBT: Niet bruikbaar. zPzB: Niet bruikbaar.

🌱 Hormoonontregelende eigenschappen

Het product bevat geen stoffen met hormoonontregelende eigenschappen.

🌱 Andere schadelijke effecten

Ecotoxische effecten: Giftig voor vissen.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

♻️ Waste Treatment Methods

Mag niet tezamen met huisvuil gestort worden of in de riolering terechtkomen.

🗂️ Product Disposal Recommendations

Afvalverwijdering volgens overheidsbepalingen.

🏷️ Waste Classification Codes

HP3 Ontvlambaar EWC
HP4 Irriterend - huidirritatie en oogletsel EWC
HP5 Specifieke doelorgaantoxiciteit (STOT)/Aspiratietoxiciteit EWC
HP14 Ecotoxisch EWC

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1950

📦 Proper Shipping Name

UN 1950 SPUITBUSSEN, 2.1, MILIEUGEVAARLIJK

⚠️ Transport Hazard Class

2.1

📋 Packing Group

vervalt

🚛 ADR Transport Precautions

Waarschuwing: Gassen -

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for BossCover SprayBond+ Cleaner Spuitbus 500ml?

The signal word for this substance is "danger".

What is the solubility of BossCover SprayBond+ Cleaner Spuitbus 500ml?

Niet resp. gering mengbaar.

What is BossCover SprayBond+ Cleaner Spuitbus 500ml used for?

Koudreinigingsmiddel

What are the hazard statements for BossCover SprayBond+ Cleaner Spuitbus 500ml?

This substance has 6 hazard statements: H222: Zeer licht ontvlambare aerosol. H229: Houder onder druk: kan open barsten bij verhitting. H315: Veroorzaakt huidirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken. H411: Giftig voor in het water levende organismen, met langdurige gevolgen. H304: Kan dodelijk zijn als de stof bij inslikken in de luchtwegen terechtkomt.

What is the melting point of BossCover SprayBond+ Cleaner Spuitbus 500ml?

The melting point is Niet bepaald and the boiling point is 82 °℃ (67-63-0 2-propanol).