NextSDS Logo
TH

THERM

NO SIGNAL WORD vloeibaar SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
THERM

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrile vloeibare ontstopper

Overview

THERM commonly used industrile vloeibare ontstopper.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Skin Corr./Eye Dam. Category 1

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

ALPHA INDUSTRIES (Prodal bvba)

manufacturer

๐Ÿ“

Oosmalsebaan 1c 2960 Sint Lenaarts

๐ŸŒ

BE

๐Ÿ“ž

+32.3.665.01.59

๐Ÿ“ 

+32.3.665.00.86

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

070.245.245

๐Ÿ’ก

Lokaal

Emergency Contact

๐Ÿ“ž

XX32.70.245.245

๐ŸŒ

BE

๐Ÿ’ก

Wereldwijd

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Zwavelzuur
EC: 231-639-5
7664-93-9 50% โš ๏ธ Hazardous

Composition Notes

Voor de volledige tekst van de H & R-zinnen die worden genoemd in deze rubriek, zie rubriek 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Bij ernstige of aanhoudende stoornissen: frisse lucht, rust en arts waarschuwen

๐Ÿ–๏ธ Skin Contact

verontreinigde kleding uittrekken, huid spoelen met veel water en onmiddellijk naar ziekenhuis vervoeren

Symptoms:

bijtend, roodheid, pijn, ernstige brandwonden

๐Ÿ‘๏ธ Eye Contact

eerst spoelen met veel water, dan naar arts vervoeren

Symptoms:

bijtend, roodheid, slecht zien, pijn

๐Ÿฝ๏ธ Ingestion/Swallowing

mond spoelen en onmiddellijk naar ziekenhuis vervoeren

Symptoms:

bijtend, ademnood, braken, blaren op lippen en tong, brandende pijn in mond en keel, slokdarm en maag

๐Ÿšจ Immediate Medical Attention Required

Steeds zo spoedig mogelijk medisch advies inwinnen in geval van ernstige of aanhoudende stoornissen. Onmiddellijk naar ziekenhuis vervoeren bij huidcontact en inslikken. Na oogcontact naar arts vervoeren.

Medical Treatment

geen

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
vloeibaar
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
vloeibaar
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
reukloos
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
0,1
๐ŸงŠ Melting Point
-20
Critical Property
๐Ÿ’จ Boiling Point
290
Critical Property
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
1,830
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
volledig oplosbaar
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
0
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
1
๐Ÿ“Š Kinematic Viscosity
1
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

handschoenen, chemisch bestendig

๐Ÿ‘๏ธ Eye Protection

veiligheidsbril

๐Ÿ˜ท Respiratory Protection

geen

๐Ÿฆบ Skin/Body Protection

beschermende kledij

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1830

๐Ÿ“ฆ Proper Shipping Name

Zwavelzuur

โš ๏ธ Transport Hazard Class

8

๐Ÿ“‹ Packing Group

II

๐Ÿš› ADR Transport Precautions

Gevaar van verbranding Kunnen onderling, met water en met andere stoffen heftig reageren.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for THERM?

The signal word for this substance is "no signal word".

What is the physical form of THERM?

THERM is a vloeibaar . It has reukloos odor.

What is THERM used for?

Industrile vloeibare ontstopper

What is the melting point of THERM?

The melting point is -20 and the boiling point is 290.