NextSDS Logo
Safety Data Sheet NL

MC-Injekt GL-95 - Komponente A 1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MC-Injekt GL-95 - Komponente A 1

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Bouwchemie, Injektionsstoffe

Uses advised against

Geen verdere relevante informatie verkrijgbaar.

Manufacturers & Suppliers

M

MC-BAUCHEMIE Müller

manufacturer

Am Kruppwald 2-8, D-46238 Bottrop

+49(0)2041 101-0

M

MC-Bauchemie N.V.

manufacturer

Intercity Business Park, Gen. De Wittelaan 17 A, B-2800 Mechelen

+32 (0)15 20 14 62

Emergency Contacts

Nationaal Vergiftigingen Informatie Centrum (NVIC)

+31 30 - 2748888

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mengsel van na elkaar aangevoerde stoffen met ongevaarlijke bijmengingen.

Notes

Gevaarlijke inhoudstoffen: vervalt

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Voor verse lucht zorgen.

Eye contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

Ingestion

Als de klachten niet minder worden, een arts consulteren

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Brandblusmaatregelen op omgeving afstemmen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Niet nodig.

Environmental

Met veel water verdunnen.

Cleanup methods

Met veel water verdunnen.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Tegen hitte en directe zonnestralen beschermen.

Storage

Geen bijzondere eisen.

Fire prevention

Geen bijzondere maatregelen noodzakelijk.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Geen aanvullende gegevens. Zie 7.

Hands

Niet noodzakelijk.

Eyes

n.n.

Respiratory

Niet noodzakelijk.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Appearance
---
Decomposition Temperature
---
Vapor Density
---
Partition Coefficient
---
Ph
6,0-6,5
Flammability
---
Auto Ignition Temperature
Het product is niet uit zichzelf ontbrandend.
Melting Point
Niet bruikbaar
Dynamic Viscosity
---
Cloud Point
---
Bulk Density
---
Molecular Weight
---
Physical State Data
liquid
Solubility In Fat
---
Solubility
---
Crystallisation Point
---
Metal Corrosion
---
Colour Intensity
---
Flash Point
niet bruikbaar
Softening Point
---
Evaporation Rate
---
Physical State
vloeibaar
Solubility In Water
volledig mengbaar
Properties Status
---
State Under Standard Conditions
---
Relative Evaporation Rate
---
Form
vloeibaar
Solidification Point
---
Density
1,2 g/cm³
Colour
blauw
Voc Content
---
Odor
reukloos
Boiling Point
---
Freezing Point
---
Odor Threshold
---
Vapor Pressure
---
Explosive Limits
---
Kinematic Viscosity
---
Relative Density
---
Upper Explosive Limit
---
Lower Explosive Limit
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Geen ontleding bij gebruik volgens voorschrift.

Reactivity

Geen verdere relevante informatie verkrijgbaar.

Hazardous reactions

Geen gevaarlijke reacties bekend.

Avoid

Geen verdere relevante informatie verkrijgbaar.

Incompatible

Geen verdere relevante informatie verkrijgbaar.

Decomposition

Geen gevaarlijke ontbindingsproducten bekend.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MC-Injekt GL-95 - Komponente A 1?

The signal word is no signal word.

What is the physical form of MC-Injekt GL-95 - Komponente A 1?

MC-Injekt GL-95 - Komponente A 1 is a vloeibaar with blauw color. It has reukloos odor.

What is MC-Injekt GL-95 - Komponente A 1 used for?

Bouwchemie, Injektionsstoffe

What is the melting point of MC-Injekt GL-95 - Komponente A 1?

The melting point is Niet bruikbaar .