NextSDS Logo
Safety Data Sheet NL

HYDROMAX

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HYDROMAX
Product Code
101990C1

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Multifunctioneel smeermiddel.

Manufacturers & Suppliers

K

KERNITE/A div. of NCH BELGIUM Inc.

manufacturer

Verbrandebrugsestwg. 58 1850 Grimbergen Belgium

(02) 255 94 40

Emergency Contacts

ANTIGIF CENTRUM/CENTRE ANTIPOISONS

(070) 24 52 45

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Dit preparaat bevat geen enkele gevaarlijke stof van deze categorie.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In geval van een massale inademing, de patiënt in de open lucht brengen, warm houden en laten rusten.

Skin contact

Gecontamineerde kledij verwijderen en de huid grondig wassen met water.

Eye contact

Onmiddellijk spoelen met water. Contactlenzen verwijderen en verder met overvloedig water blijven spoelen gedurende verschillende minuten. Medische bijstand vragen bij ontwikkeling van de irritatie.

Ingestion

NOOIT iets laten inslikken door een bewusteloos persoon.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

bluspoeder, CO2, waterspray

Unsuitable media

water onder druk

Specific hazards

overvloedige rook- en gasvorming

Firefighter Protection

Verplicht dragen van een autonoom en isolerend ademhalingstoestel

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Raadpleeg de beschermingsmaatregelen die in de rubrieken 7 en 8 vermeld staan

Environmental

Vermijd het binnendruipen in de rioleringen en waterlopen.

Cleanup methods

Bij voorkeur schoonmaken met een reinigingsmiddel; het gebruik van solventen moet vermeden worden.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

In goed geventileerde zones gebruiken.

Storage

De geopende verpakkingen moeten zorgvuldig opnieuw gesloten worden en in verticale stand bewaard worden. De grond van de lokalen moet ondoordringbaar zijn en een opvangbekken vormen.

Fire prevention

De toegang aan niet gemachtigde personen verbieden.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Let op een gepaste ventilatie, indien mogelijk, door afzuiging van de lucht op de werkplaatsen en door een geschikte algemene luchtverversing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Vluchtig vloeistof.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
Het meten van de pH-waarde is onmogelijk of de waarde is niet van toepassing.
Melting Point
niet van toepassing.
Boiling Point
niet van toepassing.
Flash Point
>190°C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
niet van toepassing.
Vapor Density
---
Relative Density
< 1
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
niet van toepassing.
Decomposition Temperature
niet van toepassing.
Solubility
---
Partition Coefficient
---
Solubility In Water
Onoplosbaar.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Avoid

hoge temperaturen

Decomposition

koolstofmonoxide en dioxide, rook en/of stikstofoxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxiciteit

Ecologische gegevens over het product zijn niet beschikbaar.

12.2 Persistentie en afbreekbaarheid

Ecologische gegevens over het product zijn niet beschikbaar.

12.3 Bioaccumulatievermogen

Ecologische gegevens over het product zijn niet beschikbaar.

12.4 Mobiliteit in de bodem

Ecologische gegevens over het product zijn niet beschikbaar.

12.5 Resultaten van PBT- en zPzB-beoordeling

Ecologische gegevens over het product zijn niet beschikbaar.

12.6 Hormoonontregelende eigenschappen

Ecologische gegevens over het product zijn niet beschikbaar.

12.7 Andere schadelijke effecten

Ecologische gegevens over het product zijn niet beschikbaar.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Vernietigen in overeenstemming met de plaatselijke richtlijnen.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Niet van toepassing.

Chemical Safety Assessment Not performed

Speciale bepalingen: - Enkel voor industrieel en institutioneel gebruik. - Buiten het bereik van kinderen bewaren.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HYDROMAX?

The signal word is no signal word.

What is the physical form of HYDROMAX?

HYDROMAX is a vluchtig vloeistof. .

What is HYDROMAX used for?

Multifunctioneel smeermiddel.

What is the melting point of HYDROMAX?

The melting point is niet van toepassing. and the boiling point is niet van toepassing..