NextSDS Logo
Di

Diphenamid

WARNING solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Diphenamid
Product Code
45455
Chemical Name
diphenamid (ISO) N , N -dimethyl-2,2-diphenylacetamide 616-007-00-2

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Laboratory chemicals, Manufacture of substances

Overview

Diphenamid (CAS: 957-51-7 ) is a solid substance commonly used laboratory chemicals, manufacture of substances.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Acute Tox. Category 4 H302
Aquatic Acute Category 3 H402
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302: Harmful if swallowed.
  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P264: Wash skin thoroughly after handling.
  • P270: Do not eat, drink or smoke when using this product.
  • P273: Avoid release to the environment.
  • P301+P312: IF SWALLOWED: Call a POISON CENTER or doctor/ physician if you feel unwell.
  • P330: Rinse mouth.
  • P501: Dispose of contents/ container to an approved waste disposal plant.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Sigma-Aldrich

manufacturer

πŸ“

3050 Spruce Street, SAINT LOUIS MO 63103, USA

🌍

US

πŸ“ž

+1 800-325-5832

πŸ“ 

+1 800-325-5052

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

πŸ“ž

+1-703-527-3887

🌍

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
diphenamid (ISO) N , N -dimethyl-2,2-diphenylacetamide 616-007-00-2
EC: 213-482-4
957-51-7 Not specified ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

πŸ–οΈ Skin Contact

Wash off with soap and plenty of water. Consult a physician.

πŸ‘οΈ Eye Contact

Flush eyes with water as a precaution.

🍽️ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ“Š Molecular Weight
Not available
βš–οΈ Density
Not available
🎨 Colour
Not available
πŸ“Š Decomposition Temperature
no data available
πŸ‘ƒ Odor
no data available
πŸ“Š Properties Status
Not available
πŸ‘οΈ Appearance
solid
πŸ“Š Solubility In Water
no data available
πŸ“Š State Under Standard Conditions
Not available
πŸ’¨ Evaporation Rate
no data available
πŸ’§ Solubility
no data available
πŸ“Š Vapor Density
no data available
πŸ”₯ Flammability
no data available
🧊 Melting Point
132 - 136 ℃ (270 - 277 ΒΊF)
Critical Property
πŸ“Š Explosive Limits
Not available
πŸ“Š Voc Content
Not available
πŸ’¨ Vapor Pressure
no data available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Colour Intensity
Not available
πŸ“Š Relative Density
no data available
πŸ“Š Odor Threshold
no data available
πŸ“Š Crystallisation Point
Not available
πŸ§ͺ Physical State
solid
Critical Property
πŸ§ͺ Ph
no data available
πŸ“Š Relative Evaporation Rate
Not available
πŸ“Š Solubility In Fat
Not available
πŸ“Š Freezing Point
Not available
πŸ“Š Dynamic Viscosity
no data available
πŸ“Š Auto Ignition Temperature
no data available
πŸ“Š Kinematic Viscosity
Not available
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Upper Explosive Limit
Not available
πŸ“Š Physical State Data
solid
πŸ”₯ Flash Point
no data available
Critical Property
πŸ’¨ Boiling Point
no data available
Critical Property
πŸ“Š Partition Coefficient
no data available
πŸ“Š Cloud Point
Not available
πŸ“Š Form
solid
πŸ“Š Bulk Density
Not available
πŸ“Š Lower Explosive Limit
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

🧀 Hand Protection

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.

πŸ‘οΈ Eye Protection

Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

😷 Respiratory Protection

For nuisance exposures use type P95 (US) or type P1 (EU EN 143) particle respirator. For higher level protection use type OV/AG/P99 (US) or type ABEK-P2 (EU EN 143) respirator cartridges. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

🦺 Skin/Body Protection

Complete suit protecting against chemicals. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

🌍 Environmental Exposure Controls

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Diphenamid?

The signal word for this substance is "warning".

What is the physical form of Diphenamid?

Diphenamid is a solid appearing as solid . It has no data available odor.

What is the solubility of Diphenamid?

no data available

What is Diphenamid used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for Diphenamid?

This substance has 2 hazard statements: H302: Harmful if swallowed. H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Diphenamid?

The melting point is 132 - 136 ℃ (270 - 277 ΒΊF) and the boiling point is no data available.