NextSDS Logo
Safety Data Sheet EN

MOL Dynamic Mistral NG 10W-30 synthetic diesel engine oil

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MOL Dynamic Mistral NG 10W-30 synthetic diesel engine oil

Regulatory Identifiers

CAS Number
N/A

Identified Uses

gas engine oil for industrial and professional use.

Uses advised against

application other than the above.

Manufacturers & Suppliers

M

MOL-LUB Lubricant Production Distribution and Service Ltd.

manufacturer

H-2931 Almásfüzitő, Fő út 21., Hungary

+36 34 526 330

M

MOL LUB Kft.

manufacturer

+36 80 201 296

Emergency Contacts

Emergency Contact

+36 34 526 210

07-15²⁰ h on workdays

Health Toxicological Information Service (ETTSZ 1097 Budapest, Albert Flórián út 2-6.)

+36 80 201 199

0-24 h, free number, can only be called from Hungary

Health Toxicological Information Service (ETTSZ 1097 Budapest, Albert Flórián út 2-6.)

+36 1 476 6464

0-24 h, can be called for a normal fee - also from abroad

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aquatic Chronic Cat. 3 H412

GHS Pictograms

Hazard Statements

H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P501 Dispose of contents/container in accordance with national regulation.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of refined mineral base oils containing additives.

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 65% No
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 35% Yes
Mineral oil mixture --- 10% Yes
Distillates (petroleum), solvent-dewaxed heavy paraffinic EC: 265-169-7 64742-65-0 2% Yes
Reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl) propionate EC: 406-040-9 125643-61-0 1.7% Yes
Bis(nonylphenyl)amine EC: 253-249-4 36878-20-3 1.7% Yes
Distillates (petroleum), solvent-dewaxed light paraffinic EC: 265-159-2 64742-56-9 1.7% Yes
Paraffin oils (petroleum), catalytic dewaxed heavy EC: 265-174-4 64742-70-7 1.7% Yes
Zinc bis[O-(6-methylheptyl)] bis[O-(sec-butyl)] bis(dithiophosphate) EC: 298-577-9 93819-94-4 1.1% Yes
Molybdenum polysulphide long chain alkyl dithiocarbamate complex EC: 457-320-2 --- 0.17% Yes
C14-16-18 Alkyl phenol EC: 931-468-2 --- 0.17% Yes
2,6-di-tert-butylphenol EC: 204-884-0 128-39-2 0.2% Yes
N,N-bis(2-ethylhexyl)-((1,2,4-triazol-1-yl)methyl)amine EC: 401-280-0 91273-04-0 0.05% Yes
Phenol, dodecyl-, branched EC: 310-154-3 121158-58-5 0.02% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the affected person to fresh air. If rapid recovery does not occur, obtain medical attention.

Skin contact

Remove contaminated clothing. Wash skin with large amounts of water, use soap. In case of persistent irritation, get medical attention.

Eye contact

Flush eyes with plenty of water for 10-15 minutes. In case of persistent irritation, get medical attention.

Ingestion

If swallowed, give water. Do not induce vomiting. Get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, carbon dioxide, dry chemical powder.

Unsuitable media

Full water jet.

Specific hazards

On burning, carbon dioxide, carbon monoxide, sulphur oxides, phosphor oxides, various hydrocarbons and soot can be formed.

Instructions

According to the existing fire-fighting regulations.

Firefighter Protection

According to the existing fire-fighting regulations. Respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Small spill

Contain the rest or small quantities with sand, earth or other suitable absorbents.

Large spill

Recover free liquid by pumping.

Environmental

Confine spills to prevent material from entering sewers, watercourses, drains and into soil

Cleanup methods

Recover free liquid by pumping. Remove from surface by skimming or suitable absorbents.

Materials: sand, earth or other suitable absorbents

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep general measures applied for normal operations with lubricants and flammable liquids. Keep away from radiant heat and open flame. Avoid contact with skin and eyes. Avoid prolonged breathing of oil vapours or mists. When using do not eat, drink or smoke. Avoid splashing the product.

Storage

Store in dry, well-ventilated place in original, closed containers. Keep away from radiant heat, open flame and strong oxidizing agents.

Hygiene

Wash hands before breaks and at end of work. Take off contaminated clothing and wash it before reuse. When using do not eat, drink or smoke.

Fire prevention

Keep away from radiant heat and open flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Not required.

Hands

Oil resistant gloves (EN 374, Breakthrough time > 480 min, PK power level: 6; PR flow rate: 0). Note: Manufacturer’s directions for use and the conditions of application should be observed.

Eyes

Where splashing is possible, wear safety glasses (EN 166).

Respiratory

Under normal conditions not required. In case of exceeded exposure-limits respiratory protection with particle-filter is recommended.

Skin/Body

Protective clothing (oil resistant).

Environmental

Do not discharge into drains/surface waters/groundwater.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
bright, clear
Colour
bright, clear
Colour Intensity
---
Form
---
Odor
characteristic
Odor Threshold
---
Ph
not applicable
Melting Point
typ. -42°C
Boiling Point
not available
Flash Point
typ. 225°C
Freezing Point
typ. -42°C
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
negligible
Vapor Density
---
Relative Density
not available
Bulk Density
---
Density
---
Flammability
combustible
Upper Explosive Limit
not explosive
Lower Explosive Limit
not explosive
Explosive Limits
---
Auto Ignition Temperature
not available
Decomposition Temperature
not available
Solubility
gasoline, kerosene, toluene, etc.
Partition Coefficient
not available
Solubility In Water
practically insoluble in water
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
100°C: typ. 12.26 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if stored and handled properly.

Reactivity

Dangerous reactivity not known.

Hazardous reactions

Not known.

Avoid

Direct heat or ignition sources.

Incompatible

Strong oxidizing agents.

Decomposition

No dangerous decomposition products are formed under normal conditions. Hazardous combustion products: See Section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Wastes of the product or used oil should be treated as hazardous waste.

Disposal

Disposal must be in compliance with national and local regulations.

Waste Codes

13 02 05* Mineral-based non-chlorinated engine, gear and lubricating oils. EWC
15 01 10* Packaging containing residues of or contaminated by dangerous substances. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
9006
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
Transport Class
9
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This safety data sheet has been prepared according to Regulation (EC) No 1907/2006 (mod.: 2020/878/EU) and to Regulation (EC) 1272/2008.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MOL Dynamic Mistral NG 10W-30 synthetic diesel engine oil?

The signal word is no signal word.

What is the physical form of MOL Dynamic Mistral NG 10W-30 synthetic diesel engine oil?

MOL Dynamic Mistral NG 10W-30 synthetic diesel engine oil is a liquid appearing as bright, clear with bright, clear color. It has characteristic odor.

What is the solubility of MOL Dynamic Mistral NG 10W-30 synthetic diesel engine oil?

gasoline, kerosene, toluene, etc.

What is MOL Dynamic Mistral NG 10W-30 synthetic diesel engine oil used for?

gas engine oil for industrial and professional use.

What are the hazard statements for MOL Dynamic Mistral NG 10W-30 synthetic diesel engine oil?

This substance has 1 hazard statement:

  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of MOL Dynamic Mistral NG 10W-30 synthetic diesel engine oil?

The melting point is typ. -42°C and the boiling point is not available.