Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- rPLA
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
3D printer filament
Manufacturers & Suppliers
Filamentive
national supplier
Bradford Chamber Business Park, Bradford, BD4 8BX
+44 (0) 33 33 66 0020
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
rPLA is based on polilactide [CAS 26100-51-6] with addition of colouring agents.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| polilactide | 26100-51-6 | --- | No |
| colouring agents | --- | --- | No |
Notes
Product does not contain components which are classified as hazardous. Product does not contain components with European Union level exposure limit in the workplace.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Call a physician immediately.
Rinse immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician. Cool skin rapidly with cold water after contact with hot product. Do not peel filament from the skin. Consult a physician.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Call a physician immediately. Avoid strong stream of water – risk of damage of the cornea. Contact an ophthalmologist.
Rinse mouth with water. Do not induce vomiting without medical advice. Call a physician immediately.
Immediate Medical Attention
Call a physician immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide, extinguishing powder, extinguishing foam, water spray.
Water jet – risk of fire propagation
During incomplete combustion release of carbon oxides, nitrogen oxides, styrene derivatives, hydrocarbons, aldehydes, ketones, acrolein, hydrogen cyanide and other harmful products of thermal decomposition may be produced.
As in any fire, wear self-contained breathing apparatus, and full protective gear.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus, and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not flush into surface and ground and ground water or sanitary sewer system.
Shovel into suitable container for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Employees should be protected from the possibility of contact with the molten filament during printing. Use personal protective equipment if necessary.
Store in cool, dry place away from naked flames. Protect from sunlight. Store in a dry place.
Store away from naked flames.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Where possible, local exhaust ventilation and good general room ventilation should be used. Provide adequate exhaust ventilation in places of dust formation.
To operate a hot product, heat resistant gloves if necessary (EN374).
Tightly fitting safety goggles if necessary (EN166).
It is not required under normal conditions of use. In the case of loose dust / fumes use a breathing apparatus.
For transport, hot, molten product - heat-resistant protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
None expected under conditions of normal use.
None expected under conditions of normal use.
Protect from direct sunlight, sources of fire and heat, except from processes connected direct use of products.
Oxidizing agents, Strong bases
No information available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Waste disposal is recommended in accordance with national and local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Not regulated.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for rPLA?
The signal word is no signal word.
What is the physical form of rPLA?
rPLA is a solid filament appearing as solid filament with based on product grade color. It has odourless odor.
What is the solubility of rPLA?
No information available
What is rPLA used for?
3D printer filament
What is the melting point of rPLA?
The melting point is No information available and the boiling point is No information available.