NextSDS Logo
Safety Data Sheet EN

Lp-PLA2 FS Reagent R1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Lp-PLA2 FS Reagent R1
Product Code
1 7181 XX XX XXX

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagent for in-vitro diagnostics in human samples

Uses advised against

For professional use only.

Manufacturers & Suppliers

DiaSys Diagnostic Systems GmbH logo

DiaSys Diagnostic Systems GmbH

manufacturer

Alte Strasse 9, DE-65558 Holzheim

+49 (0) 6432-9146-0

http://www.diasys.de

I

Infraserv

+49 (0) 69-305-6418

Emergency Contacts

Infraserv

+49 (0) 69-305-6418

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aqueous solution of inorganic salts and organic compounds.

The product does not contain dangerous substances above limits that need to be mentioned in this section according to applicable EU-legislation.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Provide fresh air. Seek medical treatment in case of troubles.

Symptoms: Respiratory tract irritation.

Skin contact

Remove residues with soap and water. Change contaminated clothing. In case of skin reactions, consult a physician.

Symptoms: Skin irritation.

Eye contact

Immediately flush eyes with plenty of flowing water for 10 to 15 minutes holding eyelids apart. Subsequently consult an ophthalmologist.

Symptoms: Eye irritation.

Ingestion

Rinse mouth and drink large quantities of water. Seek medical attention. Never give anything by mouth to an unconscious person.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Product is non-combustible. Extinguishing materials should therefore be selected according to surroundings.

Specific hazards

Fires in the immediate vicinity may cause the development of dangerous vapours.

Firefighter Protection

In case of surrounding fires: Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin and eyes.

Environmental

Do not allow to penetrate into soil, waterbodies or drains.

Cleanup methods

Soak up with absorbent materials. Wash spill area with plenty of water.

Materials: sand, siliceus earth, acid- or universal binder

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes.

Storage

Keep containers tightly closed and at a temperature between 2 °C and 8 °C.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

When dust and vapours form: Withdraw by suction.

Hands

Protective gloves according to EN 374. Glove material: nitrile rubber, butyl caoutchouc (butyl rubber) or fluoro rubber. Breakthrough time: >480 min. Observe glove manufacturer's instructions concerning penetrability and breakthrough time.

Eyes

Tightly sealed goggles according to EN 166.

Respiratory

Provide adequate ventilation.

Skin/Body

Wear suitable protective clothing.

Environmental

Refer to "6.2 Environmental precautions".

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
clear, colourless
Colour Intensity
---
Form
---
Odor
no characteristic odour
Odor Threshold
No data available
Ph
at 25 °C: 7,6
Melting Point
---
Boiling Point
---
Flash Point
not combustible
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
---
Vapor Density
No data available
Relative Density
---
Bulk Density
---
Density
at 20 °C: 1,028 g/mL
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
completely miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

refer to 10.3

Hazardous reactions

No hazardous reactions known.

Avoid

Protect against heat /sun rays.

Incompatible

Strong acids and alkalis

Decomposition

No decomposition when used properly. Thermal decomposition: No data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Lp-PLA2 FS Reagent R1?

The signal word is no signal word.

What is the physical form of Lp-PLA2 FS Reagent R1?

Lp-PLA2 FS Reagent R1 is a liquid with clear, colourless color. It has no characteristic odour odor.

What is Lp-PLA2 FS Reagent R1 used for?

Reagent for in-vitro diagnostics in human samples