Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Lp-PLA2 FS Reagent R3
- Product Code
- 1 7181 XX XX XXX
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 3630-W09S-P00W-9RNE
Identified Uses
Reagent for in-vitro diagnostics in human samples. For professional use only.
Manufacturers & Suppliers
DiaSys Diagnostic Systems GmbH
manufacturer
Alte Strasse 9, DE-65558 Holzheim
+49 (0) 6432-9146-0
http://www.diasys.de
Emergency Contacts
Infraserv
+49 (0) 69-305-6418
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Diethylene glycol EC: 203-872-2 | 111-46-6 | 95% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air. If victim is at risk of losing consciousness, position and transport on their side. Seek medical treatment in case of troubles.
Take off contaminated clothing and wash it before reuse. Remove residues with water. Seek medical treatment in case of troubles.
Immediately flush eyes with plenty of flowing water for 10 to 15 minutes holding eyelids apart. Remove contact lenses, if present and easy to do. Continue rinsing. Subsequently consult an ophthalmologist.
Rinse mouth immediately and drink plenty of water. Provide fresh air. Seek medical attention. Never give anything by mouth to an unconscious person.
Symptoms: Harmful if swallowed.
Immediate Medical Attention
Seek medical treatment in case of troubles. Subsequently consult an ophthalmologist. Seek medical attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray jet, alcohol resistant foam, extinguishing powder, carbon dioxide.
Full water jet
Combustible. Vapours can form explosive mixtures with air.
Cool endangered containers with water spray and, if possible, remove from danger zone.
Firefighter Protection
Wear self-contained positive pressure breathing apparatus and full firefighting protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Provide adequate ventilation. Keep unprotected people away. Avoid contact with skin and eyes. Do not breathe mist/vapours/spray. Take off contaminated clothing and wash it before reuse.
Do not allow to penetrate into soil, waterbodies or drains.
Soak up with absorbent materials. Final cleaning.
Materials: sand, siliceus earth, acid- or universal binder
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Do not breathe mist/vapours/spray. Wear appropriate protective equipment. Do not eat, drink or smoke when using this product. Wash hands thoroughly after handling. Take off contaminated clothing and wash it before reuse. Have eye wash bottle or eye rinse ready at work place.
Keep containers tightly closed and at a temperature between 2 °C and 8 °C. Protect from heat and direct sunlight. Do not freeze. Protect from light. Keep sterile. Protect from moisture contamination.
Do not eat, drink or smoke when using this product. Wash hands thoroughly after handling. Take off contaminated clothing and wash it before reuse.
Keep away from sources of ignition - No smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide good ventilation and/or an exhaust system in the work area.
Protective gloves according to EN 374. Glove material: nitrile rubber-Layer thickness: 0,3 mm Breakthrough time: >480 min. Observe glove manufacturer's instructions concerning penetrability and breakthrough time.
Tightly sealed goggles according to EN 166.
If vapours form, use respiratory protection. Use filter type A (= against vapours of organic substances) according to EN 14387.
Wear suitable protective clothing.
Refer to "6.2 Environmental precautions".
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
In case of warming: On contact with air, potentially explosive mixtures may develop.
Violent reaction with: strong oxidizing agents.
Protect from frost, heat and sunlight. Protect from moisture contamination.
Strong oxidizing agents
No decomposition when used properly. No data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Lp-PLA2 FS Reagent R3?
The signal word is warning.
What is the physical form of Lp-PLA2 FS Reagent R3?
Lp-PLA2 FS Reagent R3 is a liquid with clear, colourless to yellowish color. It has like alcohol odor.
What is Lp-PLA2 FS Reagent R3 used for?
Reagent for in-vitro diagnostics in human samples. For professional use only.
What are the hazard statements for Lp-PLA2 FS Reagent R3?
This substance has 2 hazard statements:
- H302: Harmful if swallowed.
- H373: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of Lp-PLA2 FS Reagent R3?
The melting point is approx. -6,5 °C (Diethylene glycol) and the boiling point is approx. 245 °C (Diethylene glycol).