NextSDS Logo
SS

SSS/VSD Coolant

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SSS/VSD Coolant
Product Code
013-04129-000

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
laboratory and analytical use

Overview

SSS/VSD Coolant commonly used laboratory and analytical use.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

AquaPhoenix Scientific, Inc

national supplier

๐Ÿ“

860 Gitts Run Road Hanover PA 17331

๐ŸŒ

US

๐Ÿ“ž

(717) 632-1291

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

ChemTel Inc.

๐Ÿ“ž

(800) 255-3924

๐ŸŒ

US

๐Ÿ’ก

North America

ChemTel Inc.

๐Ÿ“ž

+1 (813) 248-0585

๐ŸŒ

US

๐Ÿ’ก

International

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Deionized water 7732-18-5 90% โœ“ Non-hazardous
Sodium hydroxide 1310-73-2 0.1% โš ๏ธ Hazardous
Sodium nitrite 7632-00-0 0.1% โš ๏ธ Hazardous
Benzotriazole 95-14-7 0.1% โš ๏ธ Hazardous
Sodium molybdate dihydrate 7631-95-0 0.1% โœ“ Non-hazardous
D-Gluconic acid 526-95-4 0.1% โœ“ Non-hazardous
Non-hazardous dye N/A 0.1% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. Provide fresh air.

๐Ÿ–๏ธ Skin Contact

Wash with plenty of soap and water.

๐Ÿ‘๏ธ Eye Contact

Remove contact lenses, if present and easy to do. Continue rinsing. Irrigate copiously with clean, fresh water for at least 10 minutes, holding the eyelids apart.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth with water (only if the person is conscious). Do NOT induce vomiting.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
blue
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
odourless
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
<9
๐ŸงŠ Melting Point
< 0 C
Critical Property
๐Ÿ’จ Boiling Point
101 C
Critical Property
๐Ÿ”ฅ Flash Point
not determined
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
< 23.7 mmHg at 25 C
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
not determined
Critical Property
๐Ÿ”ฅ Flammability
non-combustible
๐Ÿ“Š Upper Explosive Limit
not determined
๐Ÿ“Š Lower Explosive Limit
not determined
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
not determined
๐Ÿ“Š Decomposition Temperature
not relevant
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
this information is not available
๐Ÿ“Š Solubility In Water
miscible in any proportion
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
not determined
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

General ventilation.

๐Ÿงค Hand Protection

Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. Check leak-tightness/impermeability prior to use. In the case of wanting to use the gloves again, clean them before taking off and air them well. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves.

๐Ÿ‘๏ธ Eye Protection

Wear eye/face protection.

๐Ÿ˜ท Respiratory Protection

In case of inadequate ventilation wear respiratory protection.

๐Ÿฆบ Skin/Body Protection

Take recovery periods for skin regeneration. Preventive skin protection (barrier creams/ointments) is recommended. Wash hands thoroughly after handling.

๐ŸŒ Environmental Exposure Controls

Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SSS/VSD Coolant?

The signal word for this substance is "no signal word".

What is the physical form of SSS/VSD Coolant?

SSS/VSD Coolant is a liquid with blue color. It has odourless odor.

What is SSS/VSD Coolant used for?

laboratory and analytical use

What is the melting point of SSS/VSD Coolant?

The melting point is < 0 C and the boiling point is 101 C.