NextSDS Logo
Safety Data Sheet EN

FIREY PICKLE PRI

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FIREY PICKLE PRI
Product Code
E24018593

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Perfume composition, flavour or aromatical ingredient, for an industrial usage, that can be used in end-user product.

Manufacturers & Suppliers

M

MANE IBERICA, SA

formulator

Carretera de Molins de Rei a Sabadell, km13.3- 08191 RubíSPAIN

(34) 93 588 12 21

Emergency Contacts

NCEC (regional)

+44 1865 407333

Official advisory body

070245245

NCEC (Middle East/Africa)

+44 1235 239671

NCEC (Americas)

+1 215 207 0061

NCEC (Asia)

+65 3158 1074

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Eye Dam. Cat. 1

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H318 Causes serious eye damage.

Precautionary Statements

P280 Wear protective gloves/protective clothing/eye protection/face protection.
P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.Immediately call a POISON CENTER or doctor/physician.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
SODIUM DIACETATE 126-96-5 1 - 5% Yes
MALIC ACID 6915-15-7 1 - 5% Yes
CITRIC ACID 77-92-9 1 - 5% Yes

Notes

The REACH number is specific to V MANE FILS legal entity. Ingredients having an occupational exposure limit value: See section 8.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Skin contact

Remove/take off immediately all contaminated clothing. Rinse skin with water/shower.

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Rinse mouth. Do NOT induce vomiting.

Immediate Medical Attention

Get medical attention if symptoms persist.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, CO2 or Foam

Unsuitable media

Avoid water in straight hose stream; will scatter and spread fire.

Specific hazards

Avoid breathing dust or vapor.

Instructions

Cool containers exposed to flames with water until well after the fire is out.

Firefighter Protection

No specific precautions.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Contain spillages with sand, earth or any suitable adsorbent material. Collect with non-combustible absorbent material. Flush with water. Dike for large spills.

Large spill

Dike for large spills.

Environmental

There must be no release into the environment.

Cleanup methods

Collect with non-combustible absorbent material. Flush with water.

Materials: non-combustible absorbent material.

Related Substances

Similar chemicals with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Extinguish all ignition sources. Avoid sparks, flames, heat and smoking. Ventilate. Store in a cool, dry place with adequate ventilation. Keep away from incompatible materials, open flames, and high temperatures. Do not breathe vapor from heated material.

Storage

Store in a cool, dry place with adequate ventilation. Keep away from incompatible materials, open flames, and high temperatures. Keep only in the original container in an appropriate place.

Fire prevention

Extinguish all ignition sources. Avoid sparks, flames, heat and smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use in a well-ventilated area.

Hands

Use chemical resistant gloves in accordance with Standard EN 374 for protective gloves against chemicals. When prolonged or frequently repeated contact may occur, a glove with a protection class of 4 or higher (breakthrough time greater than 120 minutes according to Standard EN 374) is recommended. When only brief contact is expected, a glove with a protection class of 1 or higher (breakthrough time greater than 10 minutes according to Standard EN 374) is recommended. Thickness > or = 0.2 mm. Please observe the instructions regarding permeability and breakthrough time which are provided by the glove supplier. Permeation time must exceed contact time. Choose the type of gloves according to the chemical properties of the products being handled. Change gloves according to the manufacturer's recommendations or if they are damaged.

Eyes

Use safety glasses or a face shield according to Standard EN 166 and according to the hazard analysis specific to the workplace (chemical to be handled, protocol for use, frequency of use, quantity used, etc.).

Respiratory

In the event that ventilation is not sufficient to prevent inhalation of substances or reduce airborne concentrations below an established occupational exposure limit, use an adequate respiratory apparatus to supplement the engineering measures already in place. These recommendations must be adapted according to the hazard analysis specific to the workplace.

Skin/Body

Wear protective clothing covering the arms and legs. Use an apron or full suit if exposure is expected. These recommendations must be adapted according to the hazard analysis specific to the workplace.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Lower Explosive Limit
No data available.
Solubility In Fat
---
Softening Point
---
Relative Evaporation Rate
---
Metal Corrosion
---
Bulk Density
---
Molecular Weight
---
Decomposition Temperature
No data available.
Ph
No data available.
Explosive Limits
---
Flash Point
No data available.
Evaporation Rate
No data available.
Odor Threshold
---
Melting Point
No data available.
Odor
Characteristic
Cloud Point
---
Auto Ignition Temperature
No data available.
Colour Intensity
---
Vapor Density
No data available.
Vapor Pressure
No data available.
Solidification Point
---
Properties Status
---
Upper Explosive Limit
No data available.
Freezing Point
---
Colour
RED ORANGE
State Under Standard Conditions
---
Kinematic Viscosity
---
Flammability
No data available.
Boiling Point
No data available.
Voc Content
---
Partition Coefficient
No data available.
Relative Density
No data available.
Solubility
No data available.
Solubility In Water
---
Dynamic Viscosity
---
Crystallisation Point
---
Physical State
POWDER
Density
---
Form
---
Appearance
---
Physical State Data
solid
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal temperature conditions and recommended use.

Avoid

Store in a cool, dry place with adequate ventilation. Keep away from incompatible materials, open flames, and high temperatures.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Do not release into the environment. Confirm disposal procedures with environmental engineer and local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for FIREY PICKLE PRI?

The signal word is danger.

What is the physical form of FIREY PICKLE PRI?

FIREY PICKLE PRI is a powder with red orange color. It has characteristic odor.

What is the solubility of FIREY PICKLE PRI?

No data available.

What is FIREY PICKLE PRI used for?

Perfume composition, flavour or aromatical ingredient, for an industrial usage, that can be used in end-user product.

What are the hazard statements for FIREY PICKLE PRI?

This substance has 1 hazard statement:

  • H318: Causes serious eye damage.

What is the melting point of FIREY PICKLE PRI?

The melting point is No data available. and the boiling point is No data available..

Compliance Scan

Free compliance check