Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Mida CHRIOX 5
- Product Form
- Mixture
- Product Code
- 555
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Biocide, Stabilised mixture of peracetic acid, hydrogen peroxide, acetic acid and water
Uses advised against
No additional information available
Manufacturers & Suppliers
Christeyns NV
manufacturer
Afrikalaan 182, 9000 GENT
+32 (0)9/ 223 38 71
http://www.christeyns.com
Christeyns UK Ltd.
distributor
Rutland Street, GB Bradford BD4 7EA
+44 (0)1274 39 32 86
http://www.christeyns.com
Christeyns Food Hygiene Ltd. Ltd
distributor
2, Cameron Court, Winwick Quay, GB WA2 8RE Warrington, Cheshire
+44 (0)1925 23 46 96
http://www.christeyns.com
Christeyns Technologies Ireland Ltd
distributor
Station Road, F12 YW84 Newtown South Ballindine, Co. Mayo
00353 94 936 4011
http://Gannonchemicals.ie
Christeyns Technologies Ltd.
distributor
Mazars, Block 3, Harcout Centre, Harcourt Road, IE 2 Dublin
+353 1 8146022
Emergency Contacts
National Poisons Information Centre Beaumont Hospital
+353 1 809 2566
Healthcare professionals-24/7
National Poisons Information Centre Beaumont Hospital
+353 1 809 2166
public, 8am - 10pm, 7/7
National Poisons Information Service (Birmingham Centre) City Hospital
0344 892 0111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS05
GHS07
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrogen peroxide EC: 231-765-0 | 7722-84-1 | 10 - 30% | Yes |
| Acetic acid EC: 200-580-7 | 64-19-7 | 5 - 10% | Yes |
| peracetic acid EC: 201-186-8 | 79-21-0 | 3 - 5% | Yes |
Specific concentration limits: Hydrogen peroxide (CAS-no: 7722-84-1, Einecs nr: 231-765-0, EG annex nr: 008-003-00-9, REACH-no: 01-2119485845 22): (5 C < 8) Eye Irrit. 2, H319 (8 C < 50) Eye Dam. 1, H318 (35 C < 100) STOT SE 3, H335 (35 C < 50) Skin Irrit. 2, H315 (50 C < 70) Skin Corr. 1B, H314 (50 C < 70) Ox. Liq. 2, H272 (63 C < 100) Aquatic Chronic 3, H412 (70 C < 100) Skin Corr. 1A, H314 (70 C < 100) Ox. Liq. 1, H271 Acetic acid (CAS-no: 64-19-7, Einecs nr: 200-580-7, EG annex nr: 607-002-00-6, REACH-no: 01-2119475328 30): (10 C < 25) Eye Irrit. 2, H319 (10 C < 25) Skin Irrit. 2, H315 (25 C < 90) Skin Corr. 1B, H314 (90 C 100) Skin Corr. 1A, H314 peracetic acid (CAS-no: 79-21-0, Einecs nr: 201-186-8, EG annex nr: 607-094-00-8, REACH-no: 01-2119531330 56): (1 C 100) STOT SE 3, H335
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing. Give oxygen or artificial respiration if necessary.
Symptoms: irritation (cough, short breathing, difficulty in breathing)
Take off immediately all contaminated clothing. Rinse skin with water/shower. Immediately call a POISON CENTER/doctor.
Symptoms: Burns. irritation (itching, redness, blistering).
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor.
Symptoms: Corrosive to eyes. redness, itching, tears.
Rinse mouth out with water. Do NOT induce vomiting. Immediately call a POISON CENTER/doctor.
Symptoms: Harmful if swallowed. Burns to the gastric/intestinal mucosa. May cause gastrointestinal irritation, nausea, vomiting and diarrhoea.
Immediate Medical Attention
Immediately call a POISON CENTER/doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
water in large amounts.
May cause fire or explosion; strong oxidiser. Heat may build pressure, rupturing closed containers, spreading fire and increasing risk of burns and injuries.
Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate area.
Avoid release to the environment.
Clean contaminated surfaces with an excess of water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only outdoors or in a well-ventilated area. Never return unused material to original container. Handle in accordance with good industrial hygiene and safety procedures. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Keep away from ignition sources. Store in a well-ventilated place. Keep cool. Store in original container.
Do not eat, drink or smoke when using this product. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Chemical resistant PVC gloves (to European standard EN 374 or equivalent). Material: Nitrile rubber (NBR); Permeation: 6 (> 480 minutes); Thickness: 0,4 mm; Standard: EN ISO 374-1.
Safety glasses with side shields (EN 166)
In case of insufficient ventilation wear suitable respiratory equipment. Extra personal protection: A/P2 filter respirator for organic vapour and harmful dust. Standards: EN 14387, EN 140.
Wear suitable protective clothing minimum (EN 13034) Type 6 equipment. Long sleeved protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable in use and storage conditions as recommended in item 7.
No additional information available
Contact with alkaline products gives exothermic reaction. Heating may cause a fire or explosion.
Heating. Direct sunlight.
metals. Organic materials. Bases.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Collect all waste in suitable and labelled containers and dispose according to local legislation.
Collect all waste in suitable and labelled containers and dispose according to local legislation.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3149
- Shipping Name
- HYDROGEN PEROXIDE AND PEROXYACETIC ACID MIXTURE STABILIZED
- Transport Class
- 5.1 (8)
- Packing Group
- II
CV24
196
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Mida CHRIOX 5?
The signal word is danger.
What is the physical form of Mida CHRIOX 5?
Mida CHRIOX 5 is a liquid with colourless. color. It has acrid and pungent. odor.
What is the solubility of Mida CHRIOX 5?
Water: Soluble
What is Mida CHRIOX 5 used for?
Biocide, Stabilised mixture of peracetic acid, hydrogen peroxide, acetic acid and water
What are the hazard statements for Mida CHRIOX 5?
This substance has 6 hazard statements:
- H272: May intensify fire; oxidiser.
- H290: May be corrosive to metals.
- H302 + H332: Harmful if swallowed or if inhaled.
- H314: Causes severe skin burns and eye damage.
- H335: May cause respiratory irritation.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of Mida CHRIOX 5?
The melting point is Not determined as it is not relevant for the characterization of the product and the boiling point is ≥ 100 °C.