Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Anti-spatter fluid

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

A

Alexander BINZEL Schweißtechnik GmbH & Co.KG

manufacturer

Postfach 10 01 53 / D-35331 Giessen

+49 (0) 6408 / 59-0

B

Binzel Pty. Ltd.

distributor

42 Hinkler Rd, Mordialloc, Victoria, 3195, Australia

+61 (0)39580 6500

Emergency Contacts

Giftinformationszentrum der Länder Rheinland-Pfalz und Hessen

+49 (0)6131 / 19 24 0

Poison Information Center

131 126

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixtures

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
White mineral oil, petroleum 8042-47-5 12.5 - 25% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of unconsciousness place patient stably in side position for transportation. Supply fresh air; consult doctor in case of complaints.

Skin contact

Immediately wash with water and soap and rinse thoroughly. Seek medical treatment in case of complaints.

Eye contact

Seek medical treatment. Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor. Protect unharmed eye.

Ingestion

If symptoms persist consult doctor.

Immediate Medical Attention

No further relevant information available.

Medical Treatment

No further relevant information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam. Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

Formation of toxic gases is possible during heating or in case of fire.

Firefighter Protection

Do not inhale explosion gases or combustion gases.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away. Avoid contact with skin and eyes. Ensure adequate ventilation.

Environmental

Inform respective authorities in case of seepage into water course or sewage system. Prevent from spreading (e.g. by damming-in or oil barriers). Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Do not flush with water or aqueous cleansing agents

Materials: sand, diatomite, acid binders, universal binders, sawdust

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Store in cool, dry place in tightly closed receptacles.

Storage

Store in cool, dry place in tightly closed receptacles.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Protective gloves. Check protective gloves prior to each use for their proper condition. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. After use of gloves apply skin-cleaning agents and skin cosmetics. Material: Nitrile rubber, NBR. Recommended thickness: ≥ 0.1 mm. Penetration time: The determined penetration times according to EN 16523-1:2015 are not performed under practical conditions. Therefore a maximum wearing time, which corresponds to 50% of the penetration time, is recommended.

Eyes

Tightly sealed goggles. Protective goggles and facial protection - Classification according to EN 166

Respiratory

When used properly and under normal conditions, breathing protection is not required.

Skin/Body

protective clothing (EN 13034)

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Fluid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Yellowish
Colour Intensity
---
Form
Fluid
Odor
Nearly odourless
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Undetermined.
Boiling Point
240 C
Flash Point
190 C
Freezing Point
Undetermined.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
---
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
0.88 g/cm
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Insoluble.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
39 mm/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Results of PBT and vPvB assessment

- PBT: Not applicable. - vPvB: Not applicable.

Not applicable.

Toxicity

Toxicity - Aquatic toxicity: No further relevant information available.

No further relevant information available regarding aquatic toxicity.

Persistence and degradability

- Persistence and degradability No further relevant information available. - Behaviour in environmental systems: No further relevant information available.

No further relevant information available.

Bioaccumulative potential

No further relevant information available.

No further relevant information available.

Mobility in soil

No further relevant information available.

No further relevant information available.

Other adverse effects

No further relevant information available.

No further relevant information available.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

On the basis of the necessary technical regulations and after consultation with the disposal agent and the relevant authorities, can be disposed of with domestic waste or incinerated with domestic waste.

Disposal

On the basis of the necessary technical regulations and after consultation with the disposal agent and the relevant authorities, can be disposed of with domestic waste or incinerated with domestic waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Anti-spatter fluid?

The signal word is no signal word.

What is the physical form of Anti-spatter fluid?

Anti-spatter fluid is a fluid with yellowish color. It has nearly odourless odor.

What is the melting point of Anti-spatter fluid?

The melting point is Undetermined. and the boiling point is 240 C.