NextSDS Logo
Safety Data Sheet EN

Aristo Fluid Anti Spatter Fluid

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Aristo Fluid Anti Spatter Fluid
Product Form
Surface protection

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Prevents welding spatter from sticking

Manufacturers & Suppliers

ESAB DENTON logo

ESAB DENTON

national supplier

2800 Airport Road, Denton, TX 76207

www.esab.com

Emergency Contacts

Emergency Contact

1-800-372-2123

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
(2-methoxymethylethoxy) propanol EC: 252-104-2 34590-94-8 100% No
Glycerin EC: 200-289-5 56-81-5 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air and call for medical aid.

Eye contact

Rinse immediately with plenty of water and seek medical advice.

Ingestion

Do not induce vomiting. Drink water. Call physician immediately.

Immediate Medical Attention

Not applicable

Medical Treatment

Not applicable

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water/water spray/water jet/carbon dioxide/sand/foam/alcohol resistant foam/chemical powder for extinction.

Specific hazards

Not applicable

Firefighter Protection

Wear respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Small spill

Small amounts of spilled liquid soak up with non-flammable, absorbent material (sand, diatomite, universal binders, etc.) gather in closed container for disposal and utilized.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

gather in closed container for disposal and utilized.

Materials: non-flammable, absorbent material (sand, diatomite, universal binders, etc.)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special precautions required.

Storage

Observe official regulations on storing pressurized containers.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The usual precautionary measures are to be adhered to when handling chemicals.

Hands

Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation

Eyes

Use eye protection.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Crystallisation Point
---
Colour
Not applicable
Lower Explosive Limit
0.9 Vol %
Softening Point
---
Relative Density
Not applicable
Density
at 20 °C: 1.029 g/cm³
Decomposition Temperature
Not applicable
Bulk Density
---
Evaporation Rate
Not applicable
State Under Standard Conditions
---
Solidification Point
---
Flammability
Not applicable
Properties Status
---
Relative Evaporation Rate
---
Voc Content
---
Vapor Pressure
at 20 °C: 23 hPa
Physical State Data
liquid
Metal Corrosion
---
Appearance
Not applicable
Solubility In Water
82.0%
Ph
---
Flash Point
61 °C
Freezing Point
Not applicable
Auto Ignition Temperature
400 °C
Cloud Point
---
Dynamic Viscosity
Not applicable
Odor Threshold
Not applicable
Molecular Weight
---
Explosive Limits
---
Physical State
Fluid
Odor
characteristic
Solubility
Not applicable
Boiling Point
100 °C
Form
---
Vapor Density
Not applicable
Melting Point
Not applicable
Solubility In Fat
---
Partition Coefficient
Not applicable
Kinematic Viscosity
Not applicable
Colour Intensity
---
Upper Explosive Limit
14.0 Vol %
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Not applicable

Reactivity

Not applicable

Hazardous reactions

Not applicable

Avoid

Not applicable

Incompatible

Not applicable

Decomposition

Not applicable

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Smaller quantities can be disposed of with household waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Aristo Fluid Anti Spatter Fluid?

The signal word is no signal word.

What is the physical form of Aristo Fluid Anti Spatter Fluid?

Aristo Fluid Anti Spatter Fluid is a fluid appearing as not applicable with not applicable color. It has characteristic odor.

What is the solubility of Aristo Fluid Anti Spatter Fluid?

Not applicable

What is Aristo Fluid Anti Spatter Fluid used for?

Prevents welding spatter from sticking

What is the melting point of Aristo Fluid Anti Spatter Fluid?

The melting point is Not applicable and the boiling point is 100 °C.